Laserfiche WebLink
1. ALL WORK DONE UNDER THIS CONTRACT SHALL BE IN COMPLIANCE WITH THE FLORIDA BUILDING CODE, RESIDENTIAL (FBCR), STH <br />ED111ON t2014) AND IN CONJUNCTION WITH ASCE 7-10. <br />2. THE MINIMUM SUPERIMPOSED DESIGN LOADS ARE AS FOLLOWS; <br />A. FLOOR LIVE LOADS R301.5 (PSF) <br />1. SLEEPING ROOMS 30 <br />11. ATTICS W/ STORAGE 20 <br />Ill. ATTICS W/OUT STORAGE 10 <br />IV. POOLROOMS 75 <br />V. BALCONIES AND DECKS 40 <br />VI. STAIRS 40 <br />VII. ALL OTHER ROOMS 40 <br />B. FLOOR DEAD LOADS R301 A 15 (PSF) <br />C. ROOF LIVE LOADS R301.6 <br />1. "MINIMUM ROOF LIVE LOADS SHALL COMPLY WITH TABLE R301.6 OF THE FBCR STH EDITION (2014) <br />D� ROOF DEAD LOAD (PSF) <br />1. FIBERGLASS SHINGLES 17 (TCDL 7 & BCDL 10) <br />11. CONCRETETILES 25 (TCDL 15 & BCDL 10) <br />E. WIND LOAD CRITERIA <br />1. BASIC WIND SPEED VULT­-150 MPK VASD-1`16 MPH <br />11. EXPOSURE CATEGORY 8 <br />111. WIND DIRECTIONAILITY FACTOR (KD) 0.85 <br />IV. INTERNAL PRESSURE COEFFICIENT (GCPI) <br />ENCLOSED BUILDINGS ±0.18 <br />V. RISK CATEGORY 11 <br />F, WHERE BUILDING LOCATIONS ARE DETERMINED TO BE IN WIND BORNE DEBRIS REGIONS, ALL EXTERIOR BUILDING <br />OPENINGS SUCH AS WINDOWS AND DOORS SHALL BE PROTECTED AGAINST WIND BORNE DEBRIS BY THE INSTALLATION <br />OF STRUCTURAL PANELS OR IMPACT -RESISTANT GLASS. THESE OPENING PROTECTIONS SHALL BE DESIGNED AND <br />INSTALLED IN ACCORDANCE WITH CHAPTER 3, SECTION R301.2.1.2 OF THE FLORIDA BUILDING CODE, RESIDENTIAL, 5TH <br />EDITION (2014). <br />3. DO NOT SCALE DRAWINGS. THE CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO WORK <br />PERFORMED AND SHALL NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND. <br />4. THE CONTRACTOR SHALL BRING ERRORS AND OMISSIONS WHICH MAY OCCUR IN CONTRACT DOCUMENTS TO THE ATTENTION OF THE <br />ARCHITECT IN WRITING AND WRITTEN INSTRUCTIONS SHALL BE OBTAINED BEFORE PROCEEDING WITH THE WORK. THE CONTRACTOR <br />WILL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY ERRORS, DISCREPANCIES OR OMISSIONS IN THE CONTRACT DOCUMENTS, OF <br />WHICH THE CONTRACTOR FAILED TO NOTIFY THE ARCHITECT BEFORE CONSTRUCTION AND/011 FABRICATION OF THE WORK. <br />5. THE ARCHITECT/ENGINEER SHALL NOT BE RESPONSIBLE FOR THE SAFETY AND CONSTRUCTION PROCEDURES, TECHNIQUES, <br />OR THE FAILURE OF THE BUILDER TO CARRY OUT THE WORK IN ACCORDANCE WITH THE DRAWINGS OR THE REQUIRED CODES. <br />6, THE STRUCTURAL DESIGN IS BASED ON THE INTERACTION OF ALL PARTS OF THE COMPLETED BUILDING. THE CONTRACTOR SHALL <br />SOLELY BEAR THE RISK FOR PROVIDING ADEQUATE STABILITY AND SAFETY OF THE STRUCTURE DURING CONSTRUCTION UNTIL <br />PERMANENT MEMBERS ARE COMPLETELY INSTALLED. <br />7. DETAILS SHOWN ON THE DRAWINGS ARE TO BE CONSIDERED TYPICAL FOR ALL SIMILAR CONDITIONS. <br />& THE CONTRACTOR SHALL MAKE NO STRUCTURAL CHANGES WITHOUT WRITTEN APPROVAL FROM THE ARCHITECT/ENGINEER. <br />9. NO STRUCTURAL MEMBERS ARE TO BE CUT FOR PIPES, DUCTS, ETC. UNLESS SPECIFICALLY DETAILED. <br />10. FLOOR ELEVATIONS AT REQUIRED EGRESS DOOR SHALL MEET PROVISION OF FBCR R311.3.1. <br />11. THE MINIMUM NET CLEAR OPENING HEIGHT WIDTH FOR EGRESS WINDOWS SHALL BE 24 INCHES PER FBCR310.1.2. <br />12. THE MINIMUM NET CLEAR OPENING WIDTH WIDTH FOR EGRESS WINDOWS SHALL BE 20 INCHES PER FBCR310.1.3. <br />GARAGES AND CARPORTS <br />1. GARAGE DOOR <br />A. ENGINEERED FOR 150 MPH MIN. WIND LOAD. <br />B. DETAIL TO BE SUPPLIED BY GARAGE DOOR SUPPLIER <br />C� DETAIL TO BE ATTACHED TO PERMIT PACKAGE BY BUILDER <br />2. PER FBCR 5TH EDITION (2014) R302.5.1: OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTO A ROOM USED FOR SLEEPING PURPOSES <br />SHALL NOT BE PERMITTED. OTHER OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE EQU4PPED WITH SOLID WOOD <br />DOORS NOT LESS THAN 13/8 INCHES IN THICKNESS, SOLID OR HONEYCOMB CORE STEEL DOORS NOT LESS THAN 1-3/8 INCHES THICK, <br />OR 2D-MINUTE FIRE -RATED DOORS AND MUST BE EQUIPPED Wl A SELF-CLOS114G DEVICE PER R302.5.1 OF FBCR (2014). <br />3. PER FBCR STH EDITION (2014) R302.5.2: DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING <br />THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM NO, 26 GAGE (0.48 MM) SHEET STEEL 1 - MIN. RIGID <br />NOWMETALLIC CLASS OR CLASS 1 DUCT BOARD OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE. <br />4. PER FBCR 5TH EDITION (2014) R302.6 &TABLE R3OZ6: THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC <br />AREA BY NOT LESS THAN % -INCH GYPSUM BOARD APPLIED TO THE GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMS <br />SHALL BE SEPARATED FROM ALL HABITABLE ROOMS ABOVE BY NOT LESS THAN 5 / 8 -INCH TYPE X GYPSUM BOARD OR <br />EQUIVALENT. WHERE THE SEPARATION IS A FLOOR -CEILING ASSEMBLY, THE STRUCTURE SUPPORTING THE SEPARATION SHALL <br />ALSO BE PROTECTED BY NOT LESS THAN'kINCH GYPSUM BOARD OR EQUIVALENT, <br />WE WORK <br />1. REFER TO THE SOILS REPORT FOR SPECIFIC DESIGN REQUIREMENTS. <br />2. REFER TO THE CIVIL DRAWINGS FOR LOCATION OF BUILDING WORKING POINTS, ROUGH GRADING, ON -SITE UTILITIES, SITE <br />IMPROVEMENTS, SITE RETAINING WALM AND SPECIFIC GENERAL NOTES. THE SOILS REPORT AND CIVIL DRAWINGS SHALL OVERRIDE <br />CONFLICTS WITH SITE WORK NOTED HEREIN.SEE LANDSCAPE DRAWINGS FOR FINAL FINISH GRADES, PLANTING AND IRRIGATIONL <br />3. RATIONAL ANALYSIS WAS PERFORMED TO DETERMINE SIZE AND STEEL REINFORCING FOR ALL FOUNDATIONS. DESIGN WAS BASED ON <br />AN ALLOWABLE SOIL BEARING CAPACITY OF 2,000 PSF. TRANSFER REINFORCING (TOP STEEL) HAS BEEN DELETED UNLESS NOTED <br />OTHERWISE. <br />4. ELEVATIONS SHOWN ON THE SITE DRAWINGS ARE MINIMUM REQUIRED DEPTHS, IF DIFFERENT CONTACT THE ARCHITECT. <br />5. NO EXCAVATION SHALL BE MADE WHOSE DEPTH BELOW THE FOOTING IS GREATER THAN % THE HORIZONTAL DISTANCE FROM THE <br />NEAREST EDGE OF THE FOOTING. <br />7. COMPACTION BY FLOODING OR JETTING IS STRICTLY PROHIBITED. <br />8. DO NOT BACKFILL UNTIL SLABS HAVE CURED OR HAVE BEEN PROPERLY BRACED. (WHERE APPLICABLE) <br />9. EXCAVATIONS TO BE A MINIMUM OF T- O'BEYOND NEW FOOTING LINE. <br />10, THE GENERAL CONTRACTOR MUST TAKE MEASURES TO CONTROL SOIL EROSION AS PER ALL LOCAL AND STATE REQUIREMENTS. <br />11, THIS BUILDING IS NOT DESIGNED TO BE CONSTRUCTED WITHIN A FLOOD ZONE, UNIO. CONTRACTOR IS TO VERIFY THE ELEVATION <br />OF THE FINISHED FLOOR SLAB WITH THE SIGNED AND SEALED SURVEY WHICH COMPLIES WITH ALL LOCAL CODES HAVING <br />JURISDICTION, INCLUDING ALL APPLICABLE STATE, CITY, AND COUNTY BUILDING AND ZONING CODES, <br />12. SWIMMING POOL, DECK, SPA, AND ASSOCIATED WORK IS TO BE PERMITTED SEPARATELY BY ENGINEERED SHOP DRAWINGS. <br />CONCREM <br />1. ALL CONCRETE WORK SHALL COMPLY WITH THE LATEST EDITION OF THE STANDARD SPECIFICATION FOR STRUCTURAL CONCRETE <br />IN BUILDINGS, ACI 301, AND THE BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE, ACI 318-11. <br />2. ALL CONCRETE FOR THE FOOTINGS, SLABS ON GROUND, AND MISCELLAMOUS ITEMS SHALL HAVE A MINIMUM COMPRESSIVE <br />STRENGTH OF 2500 PSI AFTER 28 DAYS, UNLESS NOTED OTHERWISE ON THE DRAWINGS AND PROVISIONS OF R4OZ2. <br />3. ALL AGGREGATES USED IN CONCRETE SHALL CONFORM TO ASTM C33-03. MAXIMUM AGGREGATE SIZE SHALL BE Y.. <br />4. PROVIDE 6% AIR ENTRAINED CONCRETE EXPOSED TO EARTH OR WEATHER. <br />5. BRACE FOUNDATION WALLS, RETAINING WALLS, DURING BACKFILLING AND TAMPING OPERATIONS. LEAVE BRACING IN POSITION <br />UNTIL PERMANENT RESTRAINTS ARE INSTALLED. <br />6. ALL EXPOSED EDGES OF CONCRETE SHALL BE CHAMFERED %*. <br />1. ENGINEERED WOOD CONSTRUCTION GUIDE <br />F. AMERICAN WOOD PRESERVERS ASSOCIATION STANDARDS <br />2. ALL STRUCTURAL LUMBER SHALL BE SOUTHERN YELLOW PINE #2 (MIN.) MACHINE GRADED LUMBER UNO. <br />Fb = 1, 100 PSI Fv = 175 PSI E = 1,400,000 PSI <br />STRUCTURAL LUMBER SHALL CONSIST OF, BUT NOT LIMITED TO; RAFTERS, VERTICAL STRONGRACKS, LEDGERS, BEAMS, <br />HEADERS, AND POSTS. <br />3. LUMBER FOR INTERIOR BEARING WALLS OR EXTERIOR WALLS SHALL BE SOUTHERN YELLOW PINE #2 (SYP #2) OR BETTER (UNLESS NOTED <br />OTHERWISE). <br />4. ALL LUMBER EXPOSED TO WEATHER, OR AGAINST SOIL, CONCRETE OR MASONRY MUST BE PRESSURE TREATED. <br />5. MINIMUM NAILING PER FBCR, 5TH EDITION (2014), SEE TYPICAL NAJLING SCHEDULE ON PLANS. <br />6. ALL BOLTS SHALL HAVE MINIMUM 2"SQUARE STANDARD CUT WASHERS UNDER HEADS AND/OR NUTS WHERE IN CONTACT NTH WOOD. <br />7. NOTCHING OR CUTTING OF FRAMING MEMBERS SHALL CONFORM TO SECTION R602.2.3 & R802.1.8. OF THE FOCR 5TH EDITION (2014). <br />8. FOR ASPHALT SHINGLE ROOFS, SHEATHING SHALL BE STRUCTURAL GRADE 7/16' OSB EXPOSURE-1 OR 117 CDX PLYWOOD SHEATHING <br />PROVIDE PANEL -CLIPS AT MID -SPAN FOR SPANS GREATER THAN IVON CENTER AND AT ALL UNBLOCKED EDGES OF PLYWOOD SHEATHING. <br />9. FOR CEMENTITIOUS TILE ROOFS, SHEATHING SHALL BE ST CDX PLYWOOD. 518' CDX SHEATHING SHALL BE INSTALLED WITH THE <br />STRENGTH AXIS RUNNING PERPENDICULAR TO THE TRUSSES AND SHALL SPAN A MINIMUM OF TWO TRUSS BAYS. PROVIDE PANEL -CLIPS <br />AT MID -SPAN FOR SPANS GREATER THAN IV ON CENTER AT ALL UN13LOCKED EDGES OF PLYWOOD SHEATHING. <br />10. FLOOR SHEATHING SHALL BE APA RATED %'SUBFLOOR T & G INTERIOR PLYWOOD, GLUED AND SCREWED. ADHESIVES CONFORMING <br />WITH PERFORMANCE SPECIFICATION AFG-01 SHALL ONLY BE USED. <br />11. WALL SHEATHING SHALL BE STRUCTURAL GRADE 7/1VOSB EXPOSURE-i OR 1/2"CDX PLYWOOD SHEATHING. <br />7. PROVIDE 6-MIL CONTINUOUS POLYETHYLENE VAPOR BARRIER MEMBRANE UNDER ALL SLABS -ON -GROUND WHERE INDICATED ON 12. MINIMUM DIMENSION OF ANY PLYWOOD SHEET SHALL BE 24AND THE MINIMUM AREA SHALL BE 8 FT . Sa. <br />DRAWINGS. SEAMS LAPPED 6 INCHES AND SEALED WITH ADHESIVE TAPE. <br />13. PROVIDE SOLID BLOCKING UNDER ALL POINT LOADS AND COLUMNS WITH 2x STRUCTURAL LLIMBER SYP #2. <br />8, CONTRACTORIOWNER TO PROVIDE SOIL REPORT TO ARCHITECT PRIOR TO ANY CONSTRUCTION. <br />14. TRUSS MANUFACTURER SHALL PROVIDE COMPLETE CALCULATIONS SHOWING INTERNAL LAYOUT, MEMBER FORCES AND STRESS CONTROL <br />MASONRY POINTS AND SUBMIT TO THE BUILDING DEPARTMENT FOR APPROVAL AND TO THE STRUCTURAL ENGINEER FOR REVIEW. ALL CALCULATIONS <br />1. MASONRY CONSTRUCTION SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE NTH THE PROVISIONS OF SECTION 606 OR WITH SHALL BE SIGNED AND SEALED BY A PROFESSIONAL CIVIL OR STRUCTURAL ENGINEER REGISTERED IN THE STATE OF THE PROPOSED <br />PROVISIONS OF TMS 402 / ACI 530 1 ASCE 5. CONSTRUCTION. <br />2. CONCRETE MASONRY UNITS SHALL BE GRADE *N7 TYPE 11 OR EQUAL AND, IN ACCORDANCE WITH ASTM C90-1 1 b, STANDARD <br />SPECIFICATIONS FOR HOLLOW LOAD -BEARING CONCRETE MASONRY UNITS, MINIMUM COMPRESSIVE STRENGTH OF F'm = 1500 <br />PSI. <br />3. OPEN-END BLOCK MAY BE SUBSTITUTED FOR STANDARD TWO CELLED BLOCK. <br />4. MORTAR SHALL BE TYPE M OR S IN ACCORDANCE WITH ASTM C27D-082, STANDARD SPECIFICATIONS FOR MORTAR FOR MASONRY. <br />5. MORTAR JOINTS FOR ALL BED AND HEAD JOINTS ARE TO BE 3/8 INCH THICK. THE BED JOINT OF THE STARTING COURSE MAY <br />VARY BUT IT SHALL NOT BE LESS THAN % INCH AND NOT MORE THAN % INCH, REFER TO FBCR 5TH EDITION (2014), SECTION R607.2.1 <br />FOR MORTAR JOINT THICKNESS TOLERANCES. <br />6. GROUT SHALL BE IN ACCORDANCE WITH ASTM C476, STANDARD SPECIFICATIONS FOR GROUT FOR MASONRY, OR 2500 PSI PEA <br />ROCK CONCRETE PER SPECIFICATIONS AND PROVISIONS OF SECTION 11609.12 OF THE FBCR 5TH EDITION (2014). <br />7. FILL CMU CELLS SOLID WITH GROUT AT ALL CELLS TO RECEIVE EXPANSION ANCHORS AND/OR VERTICAL REINFORCING. <br />8. MASONRY WALLS SHALL BE LAID IN A RUNNING BOND PATTERN OR, IF A STACK BOND PATTERN IS TO BE USED 9 GA. LADDER TYPE <br />HORIZONTAL JOINT REINFORCEMENT IS TO BE INSTALLED IN THE BED JOINTS SPACED AT IV ON CENTER (MAX). <br />REINFORCING STEEL <br />1 . ALL CONCRETE AND MASONRY STEEL REINFORCEMENTS SHALL CONFORM TO THE MANUAL OF STANDARD PRACTICE FOR DETAILING <br />REINFORCED CONCRETE STRUCTURES, ACI 315; THE STANDARD SPECIFICATIONS FOR STRUCTURAL CONCRETE IN BUILDINGS, <br />ACI 301; AND THE BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE, ACI 318-11. <br />2. REINFORCING BARS SHALL BE OF INTERMEDIATE GRADE CONFORMING TO ASTM A615, GRADE 40 (UNO), <br />3. WELDED WIRE FABRIC SHALL BE VX V- WIA X WIA AND SUPPLIED IN FLAT SHEETS OR ROLLS CONFORMING TO ASTM A185. LAP <br />SIDES AND ENDS A MINIMUM OF 12". LOCATE WWF 7 FROM THE TOP OF THE SLAB, UNLESS OTHERWISE NOTED ON THE PLANS. <br />THIS REINFORCEMENT SHALL BE SUPPORTED PER SECTION R506.2.4 <br />4. ALL VERTICAL REINFORCING BARS IN CMU CELLS SHALL BE ANCHORED INTHE FOOTING, THICKENED SLAB, BEAM OR LINTEL <br />SUPPORTING THE WALL AT THE TOP AND BOTTOM WITH MINIMUM V INCH HOOKS OR BENDS AND SHALL BE CONTINUOUS <br />THROUGHOUT THE HEIGHT OF THE WALL, WITH LAP SPLICES OF AT LEAST 25'. <br />5. RUN REINFORCING BARS CONTINUOUSLY LAPPED AT SPLICES AND AROUND CORNERS. DOWEL INTO INTERSECTING WALLS AND <br />HOOK AT ENDS. STAGGER SPLICES AT LEAST 2Y WHEREVER POSSIBLE. <br />6. CLEARANCE OF MAIN REINFORCING BARS FROM ADJACENT CONCRETE SURFACES SHALL BE: <br />A. CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH _3' <br />B. CONCRETE EXPOSED TO EARTH OR WEATHER: <br />1. #5, W31 OR D31 AND SMALLER 2' <br />C. CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND: <br />1. #11 AND SMALLER <br />D. BEAMS, COLUMNS: <br />1. PRIMARY REINFORCEMENT, TIES, STIRRUPS, SPIRALS IV <br />7. DO NOT CUT OR DISPLACE REINFORCING STEEL TO ACCOML40DATE THE INSTALLATION OF EMBEDDED ITEMS WITHOUT THE <br />APPROVAL OF THE ARCHITECT. <br />TIMBER <br />I . ALL WOODS AND WOOD CONSTRUCTION SHALL COMPLY WITH SPECIFICATIONS AND CODES MODIFICATIONS AS SPECIFIED HEREIN: <br />A AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (STANDARDS MANUAL) <br />B. NATIONAL FOREST PRODUCTS ASSOCIATION: <br />1. NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION <br />C. SOUTHERN PINE INSPECTION BUREAU: <br />1. STANDARD GRADING RULES FOR SOUTHERN PINE LUMBER <br />D. TRUSS PLATE INSTITUTE: <br />INATIONAL DESIGN STANDARDS FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES (rPI-1-07) <br />15. TRUSS MANUFACTURER WILL PROVIDE CALCULATIONS INDICATING ADDITIONAL DEAD LOADS FOR THE ROOF LOCATIONS WITH GUSSETS, <br />CRICKETS AND VALLEY LOCATIONS REQUIRING ADDITIONAL ROOF FRAMING FOR INTERSECTIONS OF HIGHER OR LOWER ROOFS IN <br />ACCORDANCE WITH ANSI A58A-1982. <br />16. PREFABRICATED TRUSS TOP AND BOTTOM CHORD LOADS SHALL BE PER THE RECOMMENDED MINIMUM DESIGN LOADS IN APPENDIX 8 OF <br />THE ANSIrrPI 1-2007 NATIONAL DESIGN STANDARD FOR METAL PLATE CONNECTED WOOD TRUSS CONSTRUCTION. LIVE LOAD DEFLECTIONS <br />SHALL BE LIMITED TO U360. DEAD PLUS LIVE LOAD DEFLECTIONS SHALL BE LIMITED TO U240. <br />17. THE CONNECTIONS FOR ALL TIMBER EXPOSED TO EXTERIOR ELEMENTS OR TO PRESSURE TREATED LUMBER SHALL BE GALVANIZED OR <br />PAINTED WITH A CORROSION RESISTANT POLYMER PAINT. <br />18, ALL SHEET METAL FRAMING CONNECTORS SHOWN ON THE PLANS SHALL BE'SIMPSOW STRONG -TIE BY SIMPSON CO., OR EQUAL. UNLESS <br />NOTED OTHERWISE ON PLANS, INSTALL CONNECTIONS WITH THE SIZE AND NLMBER OF BOLTS/NAILS AS RECOMMENDED BY THE <br />MANUFACTURER IN THE LATEST CATALOG. <br />19, DRAFTSTOPPING SHALL BE PROVIDED IN ACCORDANCE WITH SECTION R302.12. OF THE FBCR 5TH EDITION (2014). <br />PLUMBING <br />1. SANITARY LINES SHALL BE OF CAST IRON OR PVC (SCHEDULE 40) AS APPROVED BY THE BUILDING OFFICIAL. <br />2. WATER SUPPLY LINES SHALL BE CPVC OR UPONOR PEX W (CROSS -LINKED POLYETHYLENE) WITH F1960 FITTINGS. <br />3. CONDENSATION LINES SHALL BE MINIMUM 3/4' PVC (SCHEDULE 40), INSULATED WITH 'A- AMAFLEX <br />4. SHOWER HEADS SHALL HAVE A FLOW CONTROL DEVICE TO GIVE A MAXIMUM FLOW OF 3 GPM EACH. <br />5. ALL CLEANOUTS SHALL BE FLUSH WITH GRADE. <br />6. NO VENT STACKS SHALL PASS THROUGH ROOF CRICKETS, VALLEYS, OR RIDGES. <br />7. SIZE AND LOCATION OF CLEANOUTS SHALL CONFORM TO SECTION P3005.2 OF THE FBCR 5TH EDITION (2014). <br />FD(TURE SUPPLY SIZES SHALL CONFORM TO SECTION P2903 OF THE FBCR 5TH EDITION (2014). <br />THE PLUMBER IS TO DIVERT ALL VENTS TO REAR ELEVATION WHEN POSSIBLE. <br />10. DRILLING & NOTCHING OF WOOD FRAMED STRUCTURAL MEMBERS SHALL FOLLOW PROVISIONS OF SECTION P2603.2 OF THE FBCR 5TH <br />EDITION (2014). <br />EMRIOR WALL COVEMNIGS <br />1. ALL EXTERIOR WALL COVERINGS AND SOFFITS SHALL BE CAPABLE OF RESISTING THE DESIGN PRESSURES SPECIFIED FOR THE WALLS FOR <br />COMPONENTS AND CLADDING LOADS IN ACCORDANCE WITH TABLE R301.2(2) AS MODIFIED BY TABLE R301.2(3), MANUFACTURED SOFFITS <br />SHALL BE TESTED AT 1,5 TIMES THE DESIGN PRESSURE <br />cvlrcnif%15 clulauca <br />1. WHEN PLASTERING NTH CEMENT, PLASTER SHALL NOT BE LESS THAN THREE COATS, %8' THICK, OVER FRAMED WALLS APPLIED OVER, <br />PAPER BACKED METAL LATH OR WIRE FABRIC LATH AND WITH TWO LAYERS OF VAPOR BARRIER, NOT LESS THAN 2 COATS, 1/2"THICK, <br />WHERE APPLIED OVER MASONRY OR CONCRETE. <br />2. STUCCO OR PORTLAND CEMENT PLASTER $HALL BE INSTALLED, PROPORTIONED AND MIXED IN ACCORDANCE WITH ASTM-C926-1 la & <br />ASTM-C1063-12a. <br />3. LATH & ACCESORIES PER ASTM-C-1063-1 IA & R703.6.1 OF THE FBCR, 5TH EDITION (2014). ALL STUCCO APPLICATION DETAILS, INCLUDING BUT NOT <br />LIMITEDTO: <br />ALL STUCCO CONTROL JOINTS KICK -OUT DETAILS <br />'L'FLASHING HORIZONTAL LATH AND PAPER DETAILS <br />PIPE PENETRATION DETAILS VENT PENETRATION DETAILS 91( <br />WEEP SCREED DETAILS CONDUIT PENETRATION DETAILS <br />CASING BEAD DETAILS DRIP EDGE DETAILS <br />CANTILEVER DRIP EDGE DETAILS CORNER BEAD DETAILS <br />WINDOW CASING DETAILS STUCCO TO SIDING TRANSITION DETAILS <br />WINDOW FLASHING DETAILS <br />4. SHALL BE INSTALLED PER ASTM-C1063 - 11A AND R703.6.1 OF THE FBCR, 5TH EDITION (2014) <br />2-STORY GYPSUM BOARD <br />UNDER STAIR PROTECTION: <br />1. ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALL$, UNDER STAIR SURFACE AND ANY SOFFITS PROTECTED ON THE <br />ENCLOSED SIDE WITH 11T GYPSUM BOARD. FBCR R302.7. <br />CONTROL DATE: 02/M17 <br />A 111 11 " I IT F I T 8 <br />Design <br />rouo <br />.2. <br />Groulf... <br />L441 M KUNALIJ KtAUAN ISLVU. <br />LONGWOOD, FL 32750 <br />PH: 407-77"078 <br />FAX- 407-774,4078 <br />www.abdesigngroup.com <br />L AA M. 0003325 <br />ulwiv. a LoVil <br />SILVERADO <br />LOT #13 <br />BLK #6 <br />pmonwT# <br />04128.000-01361 <br />MODRU <br />4EHB <br />"2605-HAYDEN" <br />GAIIIIAGE 8MM0. <br />LEFT <br />]PAO]lb <br />GENERAL <br />-NOTES <br />150 MPH MT. B se <br />r-p -I <br />mm 11/7/17 <br />MCAM 1/4"=1'-0" <br />GN---..,f <br />