1. ALL WORK DONE UNDER THIS CONTRACT SHALL BE IN COMPLIANCE WITH THE FLORIDA BUILDING CODE, RESIDENTIAL (FBCR� STH
<br />EDITION (2014) AND IN CONJUNCTION WITH ASCE 7-10.
<br />2. THE MINIMUM SUPERIMPOSED DESIGN LOADS AREAS FOLLOWS;
<br />A. FLOORLIVELOADS R30i.6 (PSF)
<br />1. SLEEPING ROOMS 30
<br />11. ATTICS W/ STORAGE 20
<br />Ill. ATTICS W/OUT STORAGE 10
<br />IV. POOLROOMS 75
<br />V. BALCONIES AND DECKS 40
<br />VI. STAIRS 40
<br />VIL ALL OTHER ROOMS 40
<br />8. FLOOR DEAD LOADS R301 A 15 (PSF)
<br />C. ROOF LIVE LOADS R301.6
<br />1. "MINIMUM ROOF LIVE LOADS SHALL COMPLY NTH TABLE R301.6 OF THE FBCR 5TH EDITION (2014)
<br />D. ROOF DEAD LOAD (PSF)
<br />1. FIBERGLASS SHINGLES 17 (TCDL 7 & BCDL 10)
<br />11. CONCRETE TILES 25 (TCDL 15 & BCDL 10)
<br />E. WIND LOAD CRITERIA
<br />1. BASIC WIND SPEED VULT=ISO MPK VASD-116 MPH
<br />11. EXPOSURE CATEGORY B
<br />Ill. WIND DIRECTIONALITY FACTOR (KD) 0.85
<br />IV. INTERNAL PRESSURE COEFFICIENT (GCPQ
<br />ENCLOSED BUILDINGS to.le
<br />V. RISK CATEGORY 11
<br />F. WHERE BUILDING LOCATIONS ARE DETERMINED TO BE IN WIND BORNE DEBRIS REGIONS, ALL EXTERIOR BUILDING
<br />OPENINGS SUCH AS WINDOWS AND DOORS SHALL BE PROTECTED AGAINST WIND BORNE DEBRIS BY THE INSTALLATION
<br />OF STRUCTURAL PANELS OR IMPACT -RESISTANT GLASS, THESE OPENING PROTECTIONS SHALL BE DESIGNED AND
<br />INSTALLED IN ACCORDANCE WITH CHAPTER 3, SECTION R30i.2.1.2 OF THE FLORIDA BUILDING CODE, RESIDENTIAL, 5TH
<br />EDITION (2014).
<br />3. DO NOT SCALE DRAWINGS. THE C014TRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO WORK
<br />PERFORMED AND SHALL NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND.
<br />4. THE CONTRACTOR SHALL BRING ERRORS AND OMISSIONS WHICH MAY OCCUR IN CONTRACT DOCUMENTS TO THE ATTENTION OF THE
<br />ARCHITECT IN WRITING AND WRITTEN INSTRUCTIONS SHALL BE OBTAINED BEFORE PROCEEDING WITH THE WORK. THE CONTRACTOR
<br />WILL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY ERRORS, DISCREPANCIES OR OMISSIONS IN THE CONTRACT DOCUMENTS, OF
<br />WHICH THE CONTRACTOR FAILED TO NOTIFY THE ARCHITECT BEFORE CONSTRUCTION AND/OR FABRICATION OF THE WORK.
<br />5. THE ARCHITECT/ENGINEER SHALL NOT BE RESPONSIBLE FOR THE SAFETY AND CONSTRUCTION PROCEDURES, TECHNIQUES,
<br />OR THE FAILURE OF THE BUILDER TO CARRY OUT THE WORK IN ACCORDANCE WITH THE DRAWINGS OR THE REQUIRED CODES.
<br />6. THE STRUCTURAL DESIGN IS BASED ON THE INTERACTION OF ALL PARTS OF THE COMPLETED BUILDING. THE CONTRACTOR SHALL
<br />SOLELY BEAR THE RISK FOR PROVIDING ADEQUATE STABILITY AND SAFETY OF THE STRUCTURE DURING CONSTRUCTION UNTIL
<br />PERMANENT MEMBERS ARE COMPLETELY INSTALLED.
<br />7. DETAILS SHOWN ON THE DRAWINGS ARE TO BE CONSIDERED TYPICAL FOR ALL SIMILAR CONDITIONS.
<br />8. THE CONTRACTOR SHALL MAKE NO STRUCTURAL CHANGES WITHOUT WRITTEN APPROVAL FROM THE ARCHITECT/ENGINEER.
<br />9. NO STRUCTURAL MEMBERS ARE TO BE CUT FOR PIPES, DUCTS, ETC. UNLESS SPECIFICALLY DETAILED.
<br />10. FLOOR ELEVATIONS AT REQUIRED EGRESS DOOR SHALL MEET PROVISION OF FBCR R311.3.1.
<br />11. THE MINIMUM NET CLEAR OPENING HEIGHT WIDTH FOR EGRESS WINDOWS SHALL BE 24 INCHES PER FBCR310.1.2
<br />12. THE MINIMUM NET CLEAR OPENING WIDTH WIDTH FOR EGRESS WINDOWS SHALL BE 20 INCHES PER FBCR310.1.3.
<br />GARAGES AND CARPORTS
<br />1. GARAGE DOOR
<br />A. ENGINEERED FOR 150 MPH MIN. WIND LOAD.
<br />B. DETAIL TO BE SUPPLIED BY GARAGE DOOR SUPPLIER
<br />C, DETAIL TO BE ATTACHED TO PERMIT PACKAGE BY BUILDER
<br />2. PER FBCR 5TH EDITION (2014) R302.5.1: OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTO A ROOM USED FOR SLEEPING PURPOSES
<br />SHALL NOT BE PERMITTED. OTHER OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH SOLID WOOD
<br />DOORS NOT LESS THAN 1318 INCHES IN THICKNESS, SOLID OR HONEYCOMB CORE STEEL DOORS NOT LESS THAN 1-3f8 INCHES THICK,
<br />OR 20-MINUTE FIRE -RATED DOORS AND MUST BE EQUIPPED N A SELF -CLOSING DEVICE PER R3026.1 OF FBCR (2014).
<br />3. PER FBCR 5TH EDITION (2014) R302,52 DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING
<br />THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM NO. 26 GAGE (0.48 MM) SHEET STEEL I - MIN. RIGID
<br />NON-METALLIC CLASS OR CLASS 1 DUCT BOARD OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE.
<br />4. PER FBCR 5TH EDITION (2014) R302.6 &TABLE R302.6: THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC
<br />AREA BY NOT LESS THAN % -INCH GYPSUM BOARD APPLIED TO THE GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMS
<br />SHALL BE SEPARATED FROM ALL HABITABLE ROOMS ABOVE BY NOT LESS THAN 5 / 8 -INCH TYPE X GYPSUM BOARD OR
<br />EQUIVALENT. WHERE THE SEPARATION IS A FLOOR-CEIUNG ASSEMBLY, THE STRUCTURE SUPPORTING THE SEPARATION SHALL
<br />ALSO BE PROTECTED BY NOT LESS THAN/�INCH GYPSUM BOARD OR EQUIVALENT.
<br />WE WORK
<br />I . REFER TO THE SOILS REPORT FOR SPECIFIC DESIGN REQUIREMENTS.
<br />2. REFER TO THE CIVIL DRAWINGS FOR LOCATION OF BUILDING WORKING POINTS, ROUGH GRADING, 04-SITE UTILITIES, SITE
<br />IMPROVEMENTS, SITE RETAINING WALLS, AND SPECIFIC GENERAL NOTES. THE SOILS REPORT AND CIVIL DRAWINGS SHALL OVERRIDE
<br />CONFLICTS WITH SITE WORK NOTED HEREIN.SEE LANDSCAPE DRAWINGS FOR FINAL FINISH GRADES, PLANTING AND IRRIGATION.
<br />3. RATIONAL ANALYSIS WAS PERFORMED TO DETERMINE SIZE AND STEEL REINFORCING FOR ALL FOUNDATIONS. DESIGN WAS BASED ON
<br />AN ALLOWABLE SOIL BEARING CAPACITY OF 2,000 PSF. TRANSFER REINFORCING (TOP STEEL) HAS BEEN DELETED UNLESS NOTED
<br />OTHERWISE.
<br />4. ELEVATIONS SHOWN ON THE SITE DRAWINGS ARE MINIMUM REQUIRED DEPTHS, IF DIFFERENT CONTACT THE ARCHITECT.
<br />5, NO EXCAVATION SHALL BE MADE WHOSE DEPTH BELOW THE FOOTING IS GREATER THAN % THE HORIZONTAL DISTANCE FROM THE
<br />NEAREST EDGE OF THE FOOTING
<br />7. COMPACTION BY FLOODING OR JETTING IS STRICTLY PROHIBITED.
<br />8. DO NOT BACKFILL UNTIL SLABS HAVE CURED OR RAVE BEEN PROPERLY BRACED. (WHERE APPLICABLE)
<br />9. EXCAVATIONS TO BE A MINIMLN OF 3- V BEYOND NEW FOOTING LINE.
<br />10. THE GENERAL CONTRACTOR MUST TAKE MEASURES TO CONTROL SOIL EROSION AS PER ALL LOCAL AND STATE REQUIREMENTS.
<br />11. THIS BUILDING IS NOT DESIGNED TO BE CONSTRUCTED WfrHiN A FLOOD ZONE, UNO. CONTRACTOR IS TO VERIFY THE ELEVATION
<br />OF THE FINISHED FLOOR SLAB NTH THE SIGNED AND SEALED SURVEY WHICH COMPLIES WITH ALL LOCAL CODES HAVING
<br />JURISDICTION, INCLUDING ALL APPUCABLE STATE, CITY, AND COUNTY BUILDING AND ZONING CODES.
<br />12. SWIMMING POOL, DECK, SPA, AND ASSOCIATED WORK IS TO BE PERMITTED SEPARATELY BY ENGINEERED SHOP DRAWINGS.
<br />CONCREM
<br />I . ALL CONCRETE WORK SHALL COMPLY NTH THE LATEST EDITION OF THE STANDARD SPECIFICATION FOR STRUCTURAL CONCRETE
<br />IN BUILDINGS, ACI 301, AND THE BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE, Acl 318-11.
<br />2. ALL CONCRETE FOR THE FOOTINGS, SLABS ON GROUND, AND MISCELLANEOUS ITEMS SHALL HAVE A MINIMUM COMPRESSIVE
<br />STRENGTH OF 2500 PSI AFTER 28 DAYS, UNLESS NOTED OTHERWISE ON THE DRAWINGS AND PROVISIONS OF R402.2.
<br />3. ALL AGGREGATES USED IN CONCRETE SHALL CONFORM TO ASTM C33-03. MAXIMUM AGGREGATE SIZE SHALL BE V.
<br />4. PROVIDE 6% AIR ENTRAINED CONCRETE EXPOSED TO EARTH OR WEATHER.
<br />5. BRACE FOUNDATION WALLS, RETAINING WALLS, DURING BAGKFILUNG AND TAMPING OPERATIONS. LEAVE BRACING IN POSITION
<br />UNTIL PERMANENT RESTRAINTS ARE INSTALLED.
<br />6, ALL EXPOSED EDGES OF CONCRETE SHALL BE CHAMFERED %".
<br />7. PROVIDE 6-MIL CONTINUOUS POLYETHYLENE VAPOR BARRIER MEMBRANE UNDER ALL SLABS-014-GROUND WHERE INDICATED ON
<br />DRAWINGS. SEAMS LAPPED 6 INCHES AND SEALED WITH ADHESIVE TAPE.
<br />8. CONTRACTORIOWNER TO PROVIDE SOIL REPORT TO ARCHITECT PRIOR TO ANY CONSTRUCTION.
<br />MASONRY
<br />1 . MASONRY CONSTRUCTION SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE PROVISIONS OF SECTION 606 OR WITH
<br />PROVISIONS OF TMS 402 / ACI 530 / ASCE 5.
<br />2. CONCRETE MASONRY UNITS SHALL BE GRADE"W TYPE 11 OR EQUAL AND, IN ACCORDANCE WITH ASTM C90-1 lb, STANDARD
<br />SPECIFICATIONS FOR HOLLOW LOAD -BEARING CONCRETE MASONRY UNITS, MINIMUM COMPRESSIVE STRENGTH OF Fm = 1600
<br />PSI.
<br />1 OPEN-END BLOCK MAY BE SUBSTITUTED FOR STANDARD TWO CELLED BLOCK,
<br />4. MORTAR SHALL BE TYPE M OR S IN ACCORDANCE WITH ASTM C270-08Z STANDARD SPECIFICATIONS FOR MORTAR FOR MASONRY.
<br />5. MORTAR JOINTS FOR ALL BED AND HEAD JOINTS ARE TO BE 3/8 INCH THICK. THE BED JOINT OF THE STARTING COURSE MAY
<br />VARY BUT IT SHALL NOT BE LESS THAN % INCH AND NOT MORE THAN % INCH, REFER TO FBCR 5TH EDITION (2014), SECTION R607.2.1
<br />FOR MORTAR JOINT THICKNESS TOLERANCES.
<br />6. GROUT SHALL BE IN ACCORDANCE WITH ASTM C476, STANDARD SPECIFICATIONS FOR GROUT FOR MASONRY, OR 2500 PSI PEA
<br />ROCK CONCRETE PER SPECIFICATIONS AND PROVISIONS OF SECTION R609.1.2. OF THE FBCR 5TH EDITION (2014).
<br />7. FILL CMU CELLS SOLID NTH GROUT AT ALL CELLS TO RECEIVE EXPANSION ANCHORS AND/OR VERTICAL REINFORCING
<br />8. MASONRY WALLS SHALL BE LAID IN A RUNNING BOND PATTERN OR, IF A STACK BOND PATTERN IS TO BE USED 9 GA. LADDER TYPE
<br />HORIZONTAL JOINT REINFORCEMENT IS TO BE INSTALLED IN THE BED JOINTS SPACED AT 16'ON CENTER (MAX).
<br />REINFORCING STEEL
<br />1. ALL CONCRETE AND MASONRY STEEL REINFORCEMENTS SHALL CONFORM TO THE MANUAL OF STANDARD PRACTICE FOR DETAILING
<br />REINFORCED CONCRETE STRUCTURES, ACI 315; THE STANDARD SPECIFICATIONS FOR STRUCTURAL CONCRETE IN BUILDINGS,
<br />ACI 301; AND THE BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE, ACI 318-11.
<br />2. REINFORCING BARS SHALL BE OF INTERMEDIATE GRADE CONFORMING TO ASTM A615, GRADE 40 (UNO).
<br />3. WELDED WIRE FABRIC SHALL BE 6' X 6"- WIA X WIA AND SUPPLIED IN FLAT SHEETS OR ROLLS CONFORMING TO ASTM A185. LAP
<br />SIDES AND ENDS A MINIMUM OF 1 T. LOCATE WWF 2* FROM THE TOP OF THE SLAB, UNLESS OTHERWISE NOTED ON THE PLANS.
<br />THIS REINFORCEMENT SHALL BE SUPPORTED PER SECTION R506.2.4
<br />4. ALL VERTICAL REINFORCING BARS IN CMU CELLS SHALL BE ANCHORED IN THE FOOTING, THICKENED SLAB, BEAM OR LINTEL
<br />SUPPORTING THE WALL AT THE TOP AND BOTTOM WITH MINIMUM 10 INCH HOOKS OR BENDS AND SHALL BE CONTINUOUS
<br />THROUGHOUT THE HEIGHT OF THE WALL, NTH LAP SPLICES OF AT LEAST 25'.
<br />5. RUN REINFORCING BARS CONTINUOUSLY LAPPED AT SPLICES AND AROUND CORNERS. DOWEL INTO INTERSECTING WALLS AND
<br />HOOK AT ENDS. STAGGER SPLICES AT LEAST 25* WHEREVER POSSIBLE.
<br />6, CLEARANCE OF MAIN REINFORCING BARS FROM ADJACENT CONCRETE SURFACES SHALL BE:
<br />A CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH -3
<br />B. CONCRETE EXPOSED TO EARTH OR WEATHER:
<br />1. #5, W31 OR D31 AND SMALLER 2'
<br />C. CONCRETE NOT EXPOSED TO WEATHER ORIN CONTACT NTH GROUND:
<br />1. #11 AND SMALLER
<br />D. BEAMS, COLUMNS:
<br />1. PRIMARY REINFORCEMENT, TIES, STIRRUPS, SPIRALS IV
<br />7. DO NOT CUT OR DISPLACE REINFORCING STEEL TO ACCOMMODATE THE INSTALLATION OF EMBEDDED ITEMS WITHOUTTHE
<br />APPROVAL OF THE ARCHITECT.
<br />TIMBER
<br />1 . ALL WOODS AND WOOD CONSTRUCTION SHALL COMPLY WITH SPECIFICATIONS AND CODES MODIFICATIONS AS SPECIFIED HEREIN:
<br />A. AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (STANDARDS MANUAL)
<br />B. NATIONAL FOREST PRODUCTS ASSOCIATION:
<br />1. NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION
<br />C, SOU'rHERN PINE INSPECTION BUREAU:
<br />1. STANDARD GRADING RULES FOR SOUTHERN PINE LUMBER
<br />D. TRUSS PLATE INSTITUTE:
<br />I.NATIONAL DESIGN STANDARDS FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES (rPI-1-07)
<br />1. ENGINEERED WOOD CONSTRUCTION GUIDE
<br />F. AMERICAN WOOD PRESERVERS ASSOCIATION STANDARDS
<br />2. ALL STRUCTURAL LUMBER SHALL BE SOUTHERN YELLOW PINE #2 (MIN.) MACHINE GRADED LUMBER, UNO.
<br />Fb = 1, 1 DO PSI Fv = 175 PSI E = 1,400,ODO PSI
<br />STRUCTURAL LUMBER SHALL CONSIST OF, BUT NOT LIMITED TO; RAFTERS, VERTICAL STRONGBACKS, LEDGERS, BEAMS,
<br />HEADERS, AND POSTS.
<br />3. LUMBER FOR INTERIOR BEARING WALLS OR EXTERIOR WALLS SHALL BE SOUTHERN YELLOW PINE #2 (SYP #2) OR BETTER (UNLESS NOTED
<br />OTHERWISE).
<br />4. ALL LUMBER EXPOSED TO WEATHER, OR AGAINST SOIL, CONCRETE OR MASONRY MUST BE PRESSURE TREATED.
<br />5. MINIMUM NAILING PER FBCR, 5TH EDITION (2014), SEE TYPICAL NAILING SCHEDULE ON PLANS.
<br />6. ALL BOLTS SHALL HAVE MINIMUM 2SQUARE STANDARD CUT WASHERS UNDER HEADS ANDIOR NUTS WHERE IN CONTACT WITH WOOD.
<br />7. NOTCHING OR CUTTING OF FRAMING MEMBERS SHALL CONFORM TO SECTION R602.2.3 & R802.1.8. OF THE FBCR 5TH EDITION (2014).
<br />8. FOR ASPHALT SHINGLE ROOFS, SHEATHING SHALL BE STRUCTURAL GRADE 7/16"OSB EXPOSURE-1 OR I/? COX PLYWOOD SHEATHING.
<br />PROVIDE PANEL -CUPS AT MID -SPAN FOR SPANS GREATER THAN 16'ON CENTER AND AT ALL UNBLOCKED EDGES OF PLYWOOD SHEATHING.
<br />9. FOR CEMENTITIOUS TILE ROOFS, SHEATHING SHALL BE 5/8' COX PLYWOOD. 5/8' CDX SHEATHING SHALL BE INSTALLED WITH THE
<br />STRENGTH AXIS RUNNING PERPENDICULAR TO THE TRUSSES AND SHALL SPAN A MINIMUM OF TWO TRUSS BAYS. PROVIDE PANEL -CLIPS
<br />AT MID -SPAN FOR SPANS GREATER THAN 16"ON CENTER AT ALL UNBLOCKED EDGES OF PLYWOOD SHEATHING,
<br />10. FLOOR SHEATHING SHALL BE APA RATED %"SUBFLOOR T & G INTERIOR PLYWOOD, GLUED AND SCREWED, ADHESIVES CONFORMING
<br />WITH PERFORMANCE SPECIFICATION AFG-01 SHALL ONLY BE USED.
<br />11. WALL SHEATHING SHALL BE STRUCTURAL GRADE 7/16* OSB EXPOSURE-1 OR 112"CDX PLYWOOD SHEATHING.
<br />12, MINIMUM DIMENSION OF ANY PLYWOOD SHEET SHALL BE 24"AND THE MINIMUM AREA SHALL BE 8 FT SQ.
<br />13. PROVIDE SOLID BLOCKING UNDER ALL POINT LOADS AND COLUMNS WITH 2x STRUCTURAL LUMBER SYP #2.
<br />14. TRUSS MANUFACTURER SHALL PROVIDE COMPLETE CALCULATIONS SHOWING INTERNAL LAYOUT, MEMBER FORCES AND STRESS CONTROL
<br />POINTS AND SUBMIT TO THE BUILDING DEPARTMENT FOR APPROVAL AND TO THE STRUCTURAL ENGINEER FOR REVIEW. ALL CALCULATIONS
<br />SHALL BE SIGNED AND SEALED BY A PROFESSIONAL CIVIL OR STRUCTURAL ENGINEER REGISTERED IN THE STATE OF THE PROPOSED
<br />CONSTRUCTION.
<br />15. TRUSS MANUFACTURER WILL PROVIDE CALCULATIONS INDICATING ADDITIONAL DEAD LOADS FOR THE ROOF LOCATIONS WITH GUSSETS,
<br />CRICKETS AND VALLEY LOCATIONS REQUIRING ADDITIONAL ROOF FRAMING FOR INTERSECTIONS OF HIGHER OR LOWER ROOFS IN
<br />ACCORDANCE WITH ANSI A58.1-1982.
<br />16. PREFABRICATED TRUSS TOP AND BOTTOM CHORD LOADS SHALL BE PER THE RECOMMENDED MINIMUM DESIGN LOADS IN APPENDIX B OF
<br />THE ANSVTPI 1-2D07 NATIONAL DESIGN STANDARD FOR METAL PLATE CONNECTED WOOD TRUSS CONSTRUCTION. LIVE LOAD DEFLECTIONS
<br />SHALL BE LIMITED TO L/360. DEAD PLUS LIVE LOAD DEFLECTIONS SHALL BE LIMITED TO U240.
<br />17. THE CONNECTIONS FOR ALL TIMBER EXPOSED TO EXTERIOR ELEMENTS OR TO PRESSURE TREATED LUMBER SHALL BE GALVANIZED OR
<br />PAINTED WITH A CORROSION RESISTANT POLYMER PAINT.
<br />18. ALL SHEET METAL FRAMING CONNECTORS SHOWN ON THE PLANS SHALL BE'SIMPSOIT STRONG -TIE BY SIMPSON CO., OR EQUAL. UNLESS
<br />NOTED OTHERWISE ON PLANS, INSTALL CONNECTIONS NTH THE SIZE AND NUMBER OF BOLTSNAILS AS RECOMMENDED BY THE
<br />MANUFACTURER IN THE LATEST CATALOG.
<br />19. DRAFTSTOPPING SHALL BE PROVIDED IN ACCORDANCE WITH SECTION R302.12. OF THE FBCR 5TH EDITION (2014).
<br />211 Vd--it'LLej
<br />1. SANITARY LINES SHALL BE OF CAST IRON OR PVC (SCHEDULE 40) AS APPROVED BY THE BUILDING OFFICIAL.
<br />2. WATER SUPPLY LINES SHALL BE CPVC OR UPONOR PEX 'A' (CROSS -LINKED POLYETHYLENE) WITH F1960 FITTINGS.
<br />3. CONDENSATION LINES SHALL BE MINIMUM %'PVC (SCHEDULE 40), INSULATED WITH%' AMAFLEX.
<br />4. SHOWER HEADS SHALL HAVE A FLOW CONTROL DEVICE TO GIVE A MAXIMUM FLOW OF 3 GPM EACH.
<br />5 ' ALL CLEANOUTS SHALL BE FLUSH WITH GRADE,
<br />6. NO VENT STACKS SHALL PASS THROUGH ROOF CRICKETS, VALLEYS, OR RIDGE$.
<br />7. SIZE AND LOCATION OF CLEANOUTS SHALL CONFORM TO SECTION P3005.2 OF THE FBCR 5TH EDITION (2014).
<br />8. FIXTURE SUPPLY SIZES SHALL CONFORM TO SECTION P2903 OF THE FBCR 57FH EDITION (2014).
<br />9� THE PLUMBER IS TO DIVERT ALL VENTS TO REAR ELEVATION WHEN POSSIBLE.
<br />10. DRILLING& NOTCHING OF WOOD FRAMED STRUCTURAL MEMBERS SHALL FOLLOW PROVISIONS OF SECTION P2603.20F -BCR STH
<br />EDITION (2014).
<br />EMRIM WALL COVERINGS
<br />1. ALL EXTERIOR WALL COVERINGS AND SOFFITS SHALL BE CAPABLE OF RESISTING THE DESIGN PRESSURES SPECIFIED FOR THE WALLS FOR
<br />COMPONENTS AND CLADDING LOADS IN ACCORDANCE WITH TABLE R301.2(2) AS MODIFIED BY TABLE R301.2(3), MANUFACTURED SOFFITS
<br />SHALL BE TESTED AT 1.5 TIMES THE DESIGN PRESSURE
<br />EMRIOR FINISHES
<br />1 . WHEN PLASTERING NTH CEMENT, PLASTER SHALL NOT BE LESS THAN THREE COATS, Y8' THICK, OVER FRAMED WALLS APPLIED OVER
<br />PAPER BACKED METAL LATH OR WIRE FABRIC LATH AND WITH TWO LAYERS OF VAPOR BARRIER, NOT LESS THAN 2 COATS, 117 THICK,
<br />WHERE APPLIED OVER MASONRY OR CONCRETE.
<br />2. STUCCO OR PORTLAND CEMENT PLASTER SHALL BE INSTALLED, PROPORTIONED AND MIXED IN ACCORDANCE NTH ASTM-C926-1 la &
<br />ASTM-CIO63-12a.
<br />3. LATH & ACCESORIES PER ASTM-C-1063-1 1A & R703.6.1 OF THE FBCR, 5TH EDITION (2014). ALL STUCCO APPLICATION DETAILS, INCLUDING BUT NOT
<br />LIMITED TO:
<br />- ALL STUCCO CONTROL JOINTS - KICK -OUT DETAILS
<br />- 'L' FLASHING - HORIZONTAL LATH AND PAPER DETAILS
<br />PIPE PENETRATION DETAILS - VENT PENETRATION DETAILS
<br />WEEP SCREED DETAILS CONDUIT PENETRATION DETAILS
<br />CASING BEAD DETAILS DRIP EDGE DETAILS
<br />CANTILEVER DRIP EDGE DETAILS CORNER BEAD DETAILS
<br />WINDOW CASING DETAILS STUCCO TO SIDING TRANSITION DETAILS
<br />WINDOW FLASHING DETAILS
<br />4, SHALL BE INSTALLED PER ASTM_C1063 -I 1A AND R703.6,1 OF THE FBCR, 5TH EDITION (2014)
<br />2-STORY GYPSUM BOARD
<br />UNDER STAIR PROTECTION:
<br />1. ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL RAVE WALLS, UNDER STAIR SURFACE AND ANY SOFFITS PROTECTED ON THE
<br />ENCLOSED SIDE WITH 1/2' GYPSUM BOARD. FBCR R302.7,
<br />CONTROL DATE: O2/nl7
<br />A It C H I T E C T 8-1
<br />6
<br />N iFn
<br />G r ZouspO. 2.
<br />4iN - RONALD REAGAN BLVD.
<br />LONGWOOD, FL 32750
<br />PH: 407-774-6078
<br />FAX:- 407-7744078
<br />www.abdesigngroup.com
<br />AA OP. 0003325
<br />rm
<br />I
<br />�lz
<br />C4
<br />k
<br />Flnumm ag LoTil
<br />SILVERADD
<br />LOT 27
<br />BLK 6
<br />PROJWT#
<br />04128.000-02761
<br />MODM
<br />4EBB
<br />1828-CALI"
<br />GA3111AGM NWIN0.
<br />LEFT
<br />PA03M
<br />GENERAL
<br />NOTES
<br />% 150 MPH EXP. B J