My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6711 Wagon Trail St
Zephyrhills
>
Building Department
>
Building Plans
>
6711 Wagon Trail St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 1:07:26 PM
Creation date
2/24/2025 9:56:28 AM
Metadata
Fields
Template:
Building Plans
Street #
6711
Location
Wagon Trail St
Contractor
D R Horton Inc
Building Plans - Permit #
19188
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB / MASTIC. AND <br />INSTALLED AS PER FBCR 5TH EDITION (2014) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLA55 I AIR DUCT AS PER NFPA 50A 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT, FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />S. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALv. METAL. <br />OR OTHER MATERIALS AS PER FBCR 5TH EDITION (2014) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBCR 5TH EDITION <br />(2014) MECHANICAL CODE 603.1 - <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBCR 5TH EDITION (2014) MECHANICAL CODE <br />SECTION 403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -GUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />S. ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER. ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBCR 5TH <br />EDITION (2014) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />Il. DRYER BOOSTER TO BE A FANTECH OBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. 51X ELBOWS. <br />NOTE: <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />ATTIC <br />CEILING <br />EXTERIOR WALL <br />PLENUM <br />IU10 <br />T y <br />AIR RETURN <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />REFRIGERANT LINES <br />G% <br />y <br />AIR HANDLER <br />'� - <br />EXTERIOR WALL <br />III` <br />3/4' PVC CONDENSATE DRAIN LINE <br />EVAP. TRAY <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />T <br />REFRIGERANT LINES TO <br />PLATFORMRETURN <br />CONDENSING UNIT <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />- FBCR 5TH EDITION (2014) <br />MECHANICAL BLDG, CODE <br />SECTION 301.2.1.1 <br />HVAC <br />DRAINS <br />SCORIATED NICKEL FIN. FLOOR <br />BRONZE FL. PL. — — � OR WALL <br />BRASS PLUG ---C <br />RTTING OR EXTENSION TO <br />I <br />I SOIL OR WASTE AS <br />_ REQUIRED <br />INSIDE I <br />WADE 8240-K JOSAM 56000 <br />I SERIES NICKEL BRASS TOP <br />CAULK J <br />( P.V.G OPTI/SPEC <br />� <br />SEE <br />�— ------ <br />_ v J.INV. <br />9 SITE PLAN <br />FLOOR SLAB CLEAN —OUT (TYPNT) <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />--- <br />BROKEN LINE- RETURN TRUNK <br />1 <br />BALANCING DAMPER OR OBD <br />0 <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 2 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />ED <br />PASS-THRU AIR GRILL <br />SECURE STRAP TO GONG. CONDENSER <br />W/ (2)-3/16'X2' TAPCONS UNIT SIMPSON WB ROLL STRAP <br />OR EQUAL <br />;rll <br />4' CONCRETE SLAB SECURE STRAP TUNIT W/ (2) <br />18XI I/4' 9HT. MTL. SCREWS <br />` <br />CONDENSER UNIT <br />\ D <br />CONNECTION TO PAD <br />NOTE: MAIN COND. DRAIN 3/4' DIA, <br />OVER HEAD a 12' FROM STRUCTURE <br />COUNTERSUNK <br />C.C. PLUG <br />6 <br />SEE SPEC. <br />—— — — — — — — — — — <br />. —. ._� 1'-8'X8' CONC. <br />FIN. GRAD <br />OR PAvING — <br />�� FITTING OR <br />I I EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />I I <br />i ;I, III IN_y. SEE <br />—------—--`rSITE PLAN <br />NEXT. GROUND CLEAN —OUT (TYP.) <br />FIRST FLOOR MECHANICAL PLAN <br />PROGRESSIVE AIR SYSTEMS 05/20/14 <br />A R C N I T E C T S <br />6 <br />Design <br />GrousrO. ,w <br />41 N. RONALD REAGAN BLVD. <br />LONG WOOD, FL 32760 <br />PH: 407.77"078 <br />FAX 407-7744078 <br />www.a bdesigngrou P.com <br />AA N: 0003326 <br />w <br />y <br />z <br />0 <br />a <br />U <br />O <br />F <br />0 <br />V <br />SVBDIV. & LOT <br />SILVERADO <br />LOT #43 <br />BLK #6 <br />PRoJwT# <br />04128.000-04361 <br />moDEIc <br />4EBB <br />"1828—CALI" <br />GARAGE sP/ING: <br />LEFT <br />PAGE: <br />MECHANICAL <br />PLAN <br />No 150 MPH EXP. B <br />ARCHRECT � <br />DAR 10/19/17 <br />SCALE 1/4"=1'-0" <br />EiIEET <br />6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.