INSTALL W SELF -ADHERING <br />MEMBRANE FLASHING OVER <br />TOP, SIDE(S) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SEQUENCE OF FLASHING TO BE: <br />I. BOTTOM, 2. SIDES. 3. TOP <br />X' VENT CAP IS TO BE SET IN BED <br />OF SEALANT AT TOP AND <br />`.. <br />SIDES ONLY. SEALANT IS TO BE <br />TOOLED SO AS TO DEFLECT <br />it <br />L WATER AWAY FROM JOINTS. <br />I'. <br />X: E-Z BEAD ALL AROUND <br />I-: - VENT -APPLY SEALANT ALL <br />i IX <br />JOINTS AND INTERSECTIONS <br />APPLY SEALANT AT PERIMETER OF <br />BACKER ROD <br />NON -MOVABLE FRAME AND STUCCO <br />~ <br />ON ALL SIDES, Y4 CAULKING • JOINT <br />ALL AROUND <br />PER FBC R703.6.1 <br />ExItarlor lathing and plastering <br />BACKER ROD <br />Exterior use of portiand cement plaster <br />shall comply with the application <br />IX <br />X requirements of ASTM C 926-12A. <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 106_3_-12_A. <br />WRB LAYER M, 4 <br />'X <br />STUCCO WRAP i <br />HOODED VENT <br />X <br />X. J' THICK, 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />WRB LAYER -2, FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER <br />VENT (FRAME.) <br />WOOD SHEATHING <br />WRB LAYER M, <br />STUCCO WRAP <br />WRB LAYER -2, FORTIFIBER <br />BUILDING PAPER <br />WOOD <br />CONSTUCTION <br />METAL LATH <br />a' C'm <br />t <br />fati <br />VINYL CASING BEAD <br />W RAISED BAND <br />^ <br />`i: <br />V TO h' MID -WALL <br />WEEP SCREED <br />e' WIDE STRIP SELF <br />— <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYING <br />Z FLASHNG <br />STONE VENEER <br />OVER SCRATCH COAT <br />HORIZONTAL WEEP SCREED <br />W/STONE VENEER <br />(FRAME TO BLOCK) <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER *I, STUCCO WRAP) <br />WRB LAYER *2 (FORTIFIBER — — — — — <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />WOOD SHEATHING 1� <br />SELF-ADHESIVE FLASHING — — — — — <br />NOTE: <br />METAL LATH: LATH TO BE PER FBC <br />R'103.6.1 / ASTM C-84-1-0S, MIN. 25 LBS. <br />PER SQ. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />ELEC. METEf <br />VERIFY LC <br />STUCCO <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP a SIDES <br />SELF <br />FLASHING <br />UNIT <br />PREMANUF. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT 0 <br />TOP d SIDES <br />6B DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' <br />PIPE THROUGH / <br />WALL <br />l <br />6' SELF ADHESIVE - <br />FLASHING (INSTALL <br />PER MANUF. SPECS.) <br />BUILDING PAPER — <br />UNDER 'QUICK FLASH' <br />A VENT PENETRATION <br />SCALE: N.T.S. <br />I-iICCNC <br />STUCCO SRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />- - I <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CONSTRUCTION <br />WOOD SHEATHING <br />WRB LAYER M, <br />STUCCO WRAP <br />WRB LAYER 02, FORTIFIBER <br />BUILDING PAPER <br />J' THICK, 3 COAT CEMENT <br />PLASTER <br />1)8 TO Ya' MID -WALL <br />WEEP SCREED <br />�-6' SELF-ADHESIVE <br />FLASHING <br />WOOD FRAMED <br />WALL <br />ONTAL HORIZWEEP SCREED <br />( FRAME TO FRAME) <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />I50CY.4NOTE-POLYBLEND FOAM <br />')R SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />::O SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LAYER "1, <br />STUCCO WRAP <br />WOOD SHEATHING <br />APPROVED <br />HOUSEWRAP <br />BELOW <br />CUT SUCH TWA <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY TO FA( <br />EDGE <br />APPLY E-Z <br />OVER 60 MI <br />GRADE 'D' <br />FELT-PROVII <br />SEALANT AT <br />JOINTS AND <br />INTERSECTIC <br />WOOD <br />CONSTRUCTION <br />WOOD SHEATHING <br />WRB LAYER M, <br />STUCCO WRAP <br />U1RB LAYER 12, FORTINBER <br />BUILDING PAPER <br />METAL LATH <br />.1/8' TEXTURED <br />FINISH • WOOD <br />-FASTEN TO WOOD STRUCTURAL <br />MEMBER • 1' O.C. MAX <br />-X* TON MID -WALL <br />nrw nrxcn <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYING <br />-- -__-- V FINISH • MASONRY <br />�B HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK) <br />WRB LAYER "I, <br />STUCCO WRAP <br />CUT 'X' INTO <br />SELF -ADHERING <br />MEMBRANE FLASHING <br />APPLY SELF -ADHERING <br />MEMBRANE FLASHING <br />OVER BOX AND OVER <br />APPROVED WRB LAYER <br />M <br />STET= #1 <br />APPLY 60 MIN - <br />GRADE 'D' FELT <br />OVER <br />SELF -ADHERING <br />FLASHING OVER <br />APROVED <br />HOUSEWRAP <br />STET= #3 <br />8' <br />STEP *2 <br />1 <br />f <br />WRB LAYER "I, <br />STUCCO WRAP <br />SELF -ADHERING <br />MEMBRANE FLASHING <br />WRB LAYER 02, FORTIFIBER <br />BUILDING PAPER <br />STEP #,' <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ G.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />METAL LATH <br />STEP #E) STEP #� <br />OELECTRICAL RECEPTACLE <br />A R C R I T E C T a <br />GDes�n <br />rou Iae. <br />,-. LONG WOOD, FL 32750 -• <br />PH: 407-774-6078 <br />FAX: 407-7744078 <br />www.abdesigngroup.com <br />AA M: 0003325 <br />r; <br />V <br />y <br />O <br />Chi <br />C <br />F <br />O <br />F: <br />ti <br />V <br />eumrv. Z LOT <br />SILVERADO <br />LOT #1 <br />BLK #6 <br />PADJWT# <br />04128.000-00161 <br />MODMA <br />4EHB <br />"2605-HAYDEN" <br />OARAGM 8WING: <br />RIGHT <br />PAdm <br />WALL <br />ASSEMBLY <br />DETAILS <br />150 MPH UP. B <br />ARCHITECT-. <br />STATE OF FLORIDA <br />MEN <br />Laa�l�� <br />DAM NT 10/20/17 <br />a>I�T <br />WA 2 <br />