HVAC NOTES <br />1. ALL MECHANICAL EQUIPMENT $HALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS PA15 4 MASTIC. AND <br />INSTALLED AS PER FBC 6TH EDITION (2011) MECHANICAL 6LDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL IN CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, &HALL BE CONSTRUCTED OF SMOOTH GALV, METAL. <br />OR OTHER MATERIALS AS PER PBC 6TH EDITION (2011) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 6TH EDITION <br />(2011) MECHANICAL CODE 603U <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403, <br />8. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />S. ALL FIRE RATED CEILINGS AND WALLS SHALLL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND PBC 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11, DRYER BOOSTER TO BE A FANTECH DBF BOOSTER PAN OR EQUAL. <br />PANTEC 4 DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TRUNK <br />l <br />BALANCING DAMPER OR OW <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />m <br />PAS&-THRU AIR GRILL <br />NOTE <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />SECURE STRAP TO CONC. CONDENSER <br />ATTIC <br />W/ (2)-3/I6'X2' TAPCONS UNIT <br />81M -SON WB ROLL STRAP <br />OR EQUAL <br />CEILING <br />O O <br />EXTERIOR WALL <br />PLENUM <br />T y <br />AIR RETURN <br />SECURE STRAP TO UNIT W/ <br />(2) <br />4' CONCRETE SLAB <br />4BXI 1/4' SHT, MTL. SCREW& <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />CONDENSER <br />UNIT <br />AIR HANDLER--y <br />CONNECTION <br />TO PAD <br />EXTERIOR WALL <br />y <br />3/4' PVC CONDENSATE DRAIN LINE <br />NOTE: MAIN COND. DRAIN 3/4' DIA. <br />OVER HEAD • 12' FROM STRUCTURE <br />EVAP. TRAY <br />y <br />PVC SLEEVE TO LINES BELOW SLAG <br />T <br />REFRIGERANT LINES TO <br />PLATFORM <br />RETURN <br />CONDENSING UNIT <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVEO DRAIN, AS PER <br />FBCR 6TH EDITION (2011) <br />MECHANICAL SLOG. CODE <br />SECTION 3011,4 <br />HVAC <br />DRAINS <br />ILO <br />SCORIATED NICKEL <br />FIN. FLOOR <br />COUNTERSUNK <br />BRONZE FL. PL. <br />OR WALL <br />CA. PLUG <br />I'-,. <br />SEE SPEC. <br />BRASS PLUG <br />1'-8'X8' CONC. <br />FIN. GRADE <br />FITTING OR EXTENSION TO <br />OR PAVING <br />SOIL OR WASTE AS <br />FITTING OR <br />REQUIRED <br />EXTENSION TO 801E <br />WADE 8240-K JOSAM 56000 <br />OR WASTE AS <br />INSIDE <br />SERIES NICKEL BRA" TOP <br />REQUIRED <br />CAULK <br />RV.0 OPTI/SPEC <br />FLOOR SLAB CLEAN -OUT (TYPN) nEXT. GROUND CLEAN -OUT (,TYPN <br />NOTE: <br />ALL MECHANICAL EQUIPMENT <br />$HALL BE INSTALLED AT OR <br />ABOVE FPS, ELEVATION. <br />MECHANICAL PLAN <br />SCALE: 1/4 . P-0' <br />1441 N. RONALD REAGAN BLVD. <br />LONG WOOD, FL 32750 <br />PH: 407-774$O78 <br />FAX: 407-7744078 <br />www.abdosiBngrouF.com <br />AA B: 0003926 J <br />BVHDIV- Z LOT: <br />SILVERADO <br />LOT #1 <br />BLK. #11 <br />PROJECT* <br />04128.001-01111 <br />MODEL- <br />4EBB <br />"1828-CALI" <br />GARAGE SWING: <br />LEFT <br />PAGE: <br />MECHANICAL <br />PLAN <br />150 MPH EXP. B <br />�U <br />DA 8/16/18 <br />9CAum 1/4"=1'-0" <br />BIMET <br />M1 <br />