My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6764 Wagon Trail St
Zephyrhills
>
Building Department
>
Building Plans
>
6764 Wagon Trail St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 7:31:06 PM
Creation date
2/24/2025 9:49:51 AM
Metadata
Fields
Template:
Building Plans
Street #
6764
Location
Wagon Trail St
Contractor
D R Horton
Building Plans - Permit #
20445
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MF.:s. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER FBC 6TH EDITION (2011) MECHANICAL SLOG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />S. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 6TH EDITION (2011) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 6TH EDITION <br />(2011) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOUTERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />S. ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER. ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11, DRYER BOOSTER TO BE A FANTEC 4 DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />NOTE: <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />ATTIC <br />00 EXTERIOR WALL <br />PLENUM — b AIR RETURN <br />SUCTION AND LIQUID <br />AIR SUPPLY REFRIGERANT LINES <br />AIR <br />EVAP <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />m <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TRUNK <br />1 <br />BALANCING DAMPER OR 000 <br />0 <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />m <br />PASS-THRU AIR GRILL <br />SECURE STRAP TO GONC. CONDENSER <br />W/ (2)-3/I6'X2' TAPGCNa UNIT IT <br />WB ROLL STRAP <br />OR EQUAL <br />4• CONCRETE SLAB SECURE STRAP TO UNIT W/ (2) <br />AOXI 1/4' BHT. MTL. SCREWS <br />EXTERIOR WALL <br />b <br />3/4' PVC CONDENSATE DRAIN LINE <br />d <br />PVC SLEEVE TO LINES BELOW SLAB <br />T <br />REFRIGERANT LINES TO <br />RETURN <br />CONDENSING UNIT <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />FBCR 6TH EDITION (2011) <br />MECHANICAL BLOC. CODE <br />SECTION W12A <br />HVAC <br />DRAINS <br />CONDENSER UNIT <br />CONNECTION TO PAD <br />NOTE: MAIN COND. DRAIN 3/4' DIA. <br />OVER HEAD • 12' FROM STRUCTURE <br />SCORIATED NICKEL FIN. FLOOR COUNTERSUNK <br />BRONZE FL. PL. OR WALL CO. PLUG <br />BRASS PLUG <br />SEE SPEC. <br />I'-8'X8' CONC. <br />FIN. GRADE <br />FITTING OR EXTENSION TO OR PAVING <br />SOIL OR WASTE AS FITTING OR <br />REQUIRED EXTENSION TO SOIL <br />WADE 8240-K J05AM 56000 OR WASTE AS <br />INSIDE SERIES NICKEL BRA56 TOP REQUIRED <br />CAULK P.V.0 OPTI/SPEC <br />INV. SKS <br />SITE PLAN INV. _S�E�E <br />91Y TE PLAN <br />FLOOR SLAB CLEAN -OUT (TYPN� NEXT. GROUND CLEAN -OUT (TYP.) <br />MECHANICAL PLAN <br />SCALE: 1/4 • I'-0' <br />1441 N. RONALD REAGAN BLVD. <br />LONG WOOD, FL 32750 <br />PH: 407-7746078 <br />FAX 407-7744078 <br />www.abdesl$ngroup.com <br />AA * 0003326 <br />W <br />0 <br />O <br />SVHDrv. do LOT: <br />SILVERADO <br />LOT #2 <br />BLK. #11 <br />PROJECT# <br />04128.001-02111 <br />MODEL.• <br />4EAB <br />"1672-ARIA" <br />GARAGE SVRNG: <br />LEFT <br />PAGE: <br />MECHANICAL <br />PLAN <br />150 MPH EXP. B <br />J _t <br />!E <br />DATE: 8/18/18 <br />scALE: 1/4"=1'-0" <br />SHEET <br />M1 <br />