My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6788 Wagon Trail St
Zephyrhills
>
Building Department
>
Building Plans
>
6788 Wagon Trail St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 1:43:06 AM
Creation date
2/24/2025 9:47:38 AM
Metadata
Fields
Template:
Building Plans
Street #
6788
Location
Wagon Trail St
Contractor
D R Horton
Building Plans - Permit #
20446
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BACKER ROD <br />BACKER ROD <br />INSTALL 6' SELF -ADHERING <br />MEMBRANE FLASHING OVER <br />TOP, SIDE(S) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SEQUENCE OF FLASHING TO BE, <br />I. BOTTOM, 2. SIDES, 3. TOP <br />VENT CAP IS TO BE SET IN BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT IS TO BE <br />TOOLED SO AS TO DEFLECT <br />WATER AWAY FROM JOINTS, <br />E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />JOINTS AND INTERSECTIONS <br />APPLY SEALANT AT PERIMETER OF <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDES,y, CAULKING a JOINT <br />ALL AROUND <br />PER SECTION R703.7 <br />Exterior lathing and plastering <br />Exterior use of portland cement plaster <br />shall comply with the application <br />requirements of ASTM C 926-12A. <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1063-12A. <br />WRB LAYER -1, <br />i <br />I� <br />STUCCO WRAP <br />I...' <br />` <br />HOODED VENT <br />THICK, 3 COAT CEMENT <br />;I. <br />PLASTER <br />METAL LATH <br />WRB LAYER 02, FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER <br />VENT (FRAME) <br />WOOD SHEATHING <br />LAYER M, <br />STUCCO WRAP <br />LAYER 02, FORTIFIBER <br />BUILDING PAPER <br />WOOD <br />CONSTUCTION <br />METAL LATH <br />a• Clu )` VINYL CASING BEAD <br />W RAISED BAND <br />7b tr ecr.�ro TO I' rn�-WALI <br />wE <br />W WIDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYING <br />Z FLASHING <br />STONE VENEER <br />OVER SCRATCH COAT <br />HORIZONTAL WEEP SCREED <br />W/STONE VENEER <br />(FRAME TO BLOCK( <br />_ Y L J <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER "2 (FORTIFIBER — — — — — <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />SELF-ADHESIVE FLASHING — — — — NOTE - <br />METAL LATH: LATH TO BE PER SECTION <br />R103.1.1 / ASTM C-64-1-09, MIN. 2.5 LBS. <br />PER $0. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />STUCCO <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />SELF <br />FLASHING <br />UNIT <br />PREMANUR DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT • <br />TOP 4 SIDES <br />6B DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' <br />PIPE THROUGH <br />WALL <br />I <br />V SELF ADHESIVE — <br />FLASHING (INSTALL <br />PER MANUF, SPECS.) <br />BUILDING PAPER — <br />UNDER 'QUICK FLASH' <br />A VENT PENETRATION <br />SCALE: N.TS. <br />ELEC. METEF <br />VERIFY LO <br />iiRGfi I GI� J =;_=I VG <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />i <br />—ELEC. METER FIELD <br />VERIFY LOCATION <br />WOOD <br />6' SELF-ADHESIVE <br />FLASHING <br />WOOD FRAMED <br />WALL <br />HORIZONTAL WEEP SCREED <br />(FRAME TO FRAME) <br />CONSTRUCTION <br />WOOD SHEATHING <br />WRB LAYER "I, <br />STUCCO WRAP <br />WRB LAYER 02, FORTIFIBER <br />BUILDING PAPER <br />THICK, 3 COAT CEMENT <br />PLASTER <br />Ye' TO 78, MID -WALL <br />WEEP SCREED <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />-('GREAT STUFF' OR SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />PROVIDE STUCCO SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LAYER RI, <br />STUCCO WRAP <br />WOOD SHEATHING <br />APPROVED <br />HOUSEWRAP <br />BELOW <br />CUT SUCH THAT <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY TO FACE <br />EDGE <br />APPLY E-Z <br />OVER 60 MI <br />GRADE 'D' <br />FELT-PROVII <br />SEALANT AT <br />JOINTS AND <br />INTERSECTIC <br />STEP #1 <br />STEP #3 <br />WOOD SHEATHING <br />WIC LAYER "I, <br />STUCCO WRAP <br />WRB LAYER -2, FORTIFIBER <br />BUILDING PAPER <br />METAL <br />LATH <br />p <br />FINI,SN - WOOD <br />-FASTEN TO WOOD STRUCTURAL <br />MEMBER • T' OG, MAX <br />jii <br />11"P ffi <br />YING <br />(�4 HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK) <br />a' <br />WRB LAYER 01, <br />STUCCO WRAP <br />CUT 'X' INTO <br />SELF -ADHERING <br />MEMBRANE FLASHING <br />l <br />APPLY SELF -ADHERING <br />MEMBRANE FLASHING <br />OVER BOX AND OVER <br />APPROVED UM LAYER <br />M <br />STEP <br />#2 <br />WRB LAYER "I, <br />STUCCO WRAP <br />APPLY 60 MIN <br />SEMSIRAHE <br />e <br />GRADE 'D' FELT <br />MEMBRANE FLASHING <br />FLASHING; <br />OVER <br />SELF -ADHERING <br />FLASHING OVER <br />APROVED <br />HOUSEWRAP <br />WRB LAYER 2, FORTIF15ER <br />BUILDING PAPER <br />STEP <br />#4 <br />COATING OVER <br />4ELASTOMERIC <br />STUCCO/ G.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />METAL LATH <br />STEP #5 STEP #& <br />OELECTRICAL RECEPTACLE <br />1441 N.RONALD REAGAN BLVD. <br />LONG WOOD, FL 32750 <br />PH:407.774-6078 <br />FAX 407-7744078 <br />www.abdeslgngfoup.com <br />AA M. 0003325 <br />8 <br />2 <br />p <br />0 <br />a <br />D � 08/20/18 <br />SCALE: 1/4"=1'-0" <br />811=T <br />dd A2 <br />