HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALE, BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG, REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SMALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB s MASTIC. AND <br />INSTALLED AS F'ER FBC 6TH EDITION (2011) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SMALL BE CONSTRUCTED OF SMOOTH GiALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 6TH EDITION (2011) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FOC 6TH EDITION <br />(2011) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINNG BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL NAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />S. ALL FIRE RATED CEILINGS AND WALLS SMALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601, <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11. DRYER BOOSTER TO BE A PANTEC 4 DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />NOTE: <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />ATTIC <br />` <br />010 <br />EXTERIOR WALL <br />PLENUM*MECHANICAL <br />AIR RETURN <br />ON AND LIQUID <br />AIR SUPPLYGERANT <br />LINES <br />AIR HANDLERRIOR <br />WALL <br />VC CONDENSATE DRAIN LINE <br />EVAP. TRAYLEEVE <br />TO LINES BELOW SLAB <br />REFRIGERANT LINES TO <br />PLATFORMCONDENSING <br />WIT <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />FBCR 6TH EDITION (2011) <br />BLDG. CODE <br />SECTION 3012A <br />HVAC <br />DRAINS <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TRUNK <br />l <br />BALANCING DAMPER OR OBD <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />m <br />PASS-THRU AIR GRILL <br />SECURE STRAP TO CONC. CONDENSER <br />X2 W/ (2)-3/16'' TAPCONS WIT SIMPSON LLB ROLL STRAP <br />OR EQUAL <br />W CONCRETE SLAB SECURE STRAP TO WIT W/ (2) <br />SOXI 1/4' SHT. MTL. SCREWS <br />CONDENSER UNIT <br />CONNECTION TO PAD <br />NOTE, MAIN COND. DRAIN 3/4' DIA. <br />OVER HEAD * 12' FROM STRUCTURE <br />SCORIATED NICKEL COWTE.LUG <br />PP <br />FIN. FLOOR C.O. LUG <br />ESMNZE FL. PL. OR WALL I'-6 <br />� SEE SPEC. <br />BRA$$ PLUG <br />--'—FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />///--- WADE 0240-K JOSAM 56MO <br />INSIDE / SERIES NICKEL BRASS TOP <br />CAULK / P.V.0 OPTI/SPEC <br />FLOOR SLAB CLEAN -OUT (TYP.) <br />N <br />FIN. GRADE <br />OR PAVING <br />CONC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />DEXT. GROUND CLEAN -OUT (TYPN <br />MECHANICAL PLAN <br />SCALE: 1/4 • 1'-0' <br />1441 N. RONALD REAGAN BLVD. <br />LONG WOOD, FL 32750 <br />PH: 407.774-8078 <br />FAX: 407-7744078 <br />www.abdosigngroup.com <br />AA M: 0003325 J <br />h <br />Lo <br />8 <br />b <br />0 <br />k <br />c <br />sF <br />9 <br />nwH7E 08/20/18 <br />SCALE: 1/4"=1'-0" <br />SHEET <br />m1 <br />