Laserfiche WebLink
BACKER ROD <br />SACKER ROD <br />INSTALL W SELF -ADHERING <br />MEMBRANE FLASHING OVER <br />TOP, SIDE(S) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SECAJENCE OF FLASHING TO BE, <br />1. BOTTOM, 2. SIDES, 3. TOP <br />VENT CAP IS TO BE SET IN BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT IS TO SE <br />TOOLED SO AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />E-Z BEAD ALL ARMND <br />VENT -APPLY SEALANT ALL <br />JOINTS AND INTERSECTIONS <br />APPLY SEALANT AT PERIMETER OF <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDES,X' CAULKING • JOINT <br />ALL AROUND <br />PER SECTION R703.7 <br />Exterior lathing and pleatedng <br />Exterior use of portland cement plaster <br />shall comply with the application <br />requirements of ASTM C 926-12A. <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1063.12A. <br />WRB LAYER -1, <br />it "X. <br />1 <br />STUCCO WRAP <br />r. <br />HOODED VENT <br />}' HIM 3 COAT CEMENT <br />STER <br />METAL LATH <br />WRB LAYER 4, FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER <br />VENT (FRAME) <br />WOOD SHEATHING <br />WRB LAYER 9, <br />STUCCO WRAP <br />ARB LAYER P1, FORTIFISER <br />BUILDING PAPER <br />WOOD <br />CONSTUCTION <br />.,, METAL LATH <br />S' CMU ��':'-":` VINYL CASING BEAD <br />c <br />i 6' RAISED BAND <br />T01f' ac=MID-WALL <br />wear• <br />6' WIDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYING <br />Z FLASHING <br />STONE VENEER <br />OVER SCRATCH COAT <br />HORIZONTAL WEEP SCREED <br />XZSTONE VENEER <br />(FRAME TO BLOCK) <br />LEGEND <br />DRAINAGE PLANE (WR5 <br />LAYER "I, STUCCO WRAP) <br />WR5 LAYER 02 (FORTIFI5ER — — — — — <br />5UILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />5ELF-ADHE5IVE FLASHING — — — — — <br />NOTE: <br />METAL LATH: LATH TO 5E PER SECTION <br />R103.1.1 / ASTM C-841-0S, MIN. 2.5 L55. <br />PER SQ. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />STUCCO <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />SELF <br />FLASHING <br />UNIT <br />PREMANUF. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT • <br />TOP 4 SIDES <br />6B DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' <br />PIPE THROUGH <br />WALL <br />1 <br />6' SELF ADHESIVE — <br />FLASHING (INSTALL <br />PER MANUF. SPECS.) <br />BUILDING PAPER — <br />UNDER 'GUICK FLASH' <br />A VENT PENETRATION <br />SCALE, N.T.S. <br />ELEC. METEF <br />VERIFY LO <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />—ELEC. METER FIELD <br />VERIFY LOCATION <br />CONSTRUCTION <br />WOOD SHEATHING <br />WRB LAYER 01, <br />STUCCO WRAP <br />WRB LAYER 02, FORTIF15ER <br />BUILDING PAPER <br />THICK, 3 COAT CEMENT <br />Ye' TO X, MID -WALL <br />WEEP SCREED <br />�-6' SELF-ADHESIVE <br />FLASHING <br />WOOD FRAMED <br />WALL <br />HORIZONTAL WEEP SCREED <br />( FRAME TO FRAME) <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLY5LEN0 FOAM <br />-('GREAT STUFF' OR SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />PROVIDE STUCCO SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LAYER h, <br />STUCCO WRAP <br />WOOD SHEATHING <br />APPROVED <br />HOUSEWRAP <br />BELOW <br />CUT SUCH THA' <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY TO FAf <br />EDGE <br />APPLY E-Z <br />OVER 60 MI <br />GRADE 'D' <br />FELT-PROVI <br />SEALANT AT <br />JOINTS AND <br />INTERSECTIC <br />WOOD SHEATHING <br />LAYER h, <br />STUCCO WRAP <br />LAYER Q, FORTIFIBER <br />BUILDING PAPER <br />METAL LATH <br />WOOD 1Z <br />SOON TRACTION y�ISN • UlOt7D <br />FASTEN TO WOOD STRJCTURAL <br />MEMBER • T' ors, MAX <br />a' Q'lu <br />Y.'Tr )EDWGL, <br />• W WIDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYING <br />�`— FINISH • MASONRY <br />�B HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK) <br />WR5 LAYER "I, <br />STUCCO WRAP <br />CUT 'X' INTO <br />SELF -ADHERING <br />MEMBRANE FLASHING <br />APPLY SELF -ADHERING <br />MEMBRANE FLASHING <br />OVER BOX AND OVER <br />APPROVED WRS LAYER <br />STEP 1*1 <br />APPLY 60 MIN - <br />GRADE 'D' FELT <br />OVER <br />SELF -ADHERING <br />FLASHING OVER <br />APROVED <br />HOUSEWRAP <br />STEP :13 <br />8• <br />STET= #2 <br />WRB LAYER 01, <br />STUCCO WRAP <br />SELF -ADHERING <br />MEMBRANE FLASHING <br />WRB LAYER R, FORTIFIBER <br />BUILDING PAPER <br />STEP <br />04 <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ G.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />METAL LATH <br />STEP 05 5TEF No <br />OELECTRICAL RECEPTACLE <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774.6078 <br />FAX: 407-7744078 <br />www.abdeslgngroup.com <br />AA M. 0003325 <br />g <br />4 <br />V <br />0 <br />b <br />O <br />a <br />7 <br />StMDIV. as LOT <br />SILVERADO <br />LOT #5 <br />BLK. #12 <br />PROJECT* <br />04128.001-05121 <br />MODEL: <br />4EBB <br />»1828—CALI" <br />GARAGE SWING: <br />LEFT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />%150 MPH EXP. B <br />rPRAMT 8/it3/18 <br />SCALE: 1/4"=1'-0" <br />SEMEdd�TT A2 <br />