GENERAL NOTES <br />1. ALL WORK DONE UNDER THIS CONTRACT SHALL BE IN COMPUANCE WITH THE FLORIDA BUILDING CODE RESIDENTIAL (FBCR) <br />ft EDITION, (2017) .AND IN CONJUNCTION WITH ASCE 7.10. ALL REFERENCED CHAPTERS, CODE SECTIONS AND TABLES STATED <br />IN THESE DOCUMENTS ARE UNDER FBCR BTH EDITION (2017) UNO. <br />2. WHERE BUILDING LOCATIONS ARE DETERMINED TO BE IN WIND BORNE DEBRIS REGIONS, ALL EXTERIOR <br />BUILDING OPENINGS SUCH AS WINDOWS AND DOORS SHALL BE PROTECTED AGAINST WINDBORNE DEBRIS BY <br />THE INSTALLATION OF STRUCTURAL PANELS OR IMPACT -RESISTANT GLASS. THESE OPENING PROTECTIONS SHALL BE <br />DESIGNED AND INSTALLED IN ACCORDANCE WITH CHAPTER 3, SECTION R301.2.1.2. <br />3. DO NOT SCALE DRAWINGS, THE CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO WORK <br />PERFORMED AND SHALL NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND. <br />4. THE CONTRACTOR SHALL BRING ERRORS AND OMISSIONS WHICH MAY OCCUR IN CONTRACT DOCUMENTS TO THE ATTENTION <br />OF THE ARCHITECT IN WRITING AND WRITTEN INSTRUCTIONS SHALL BE OBTAINED BEFORE PROCEEDING WITH THE WORK. <br />THE CONTRACTOR WALL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY ERRORS, DISCREPANCIES OR OMISSIONS IN THE <br />CONTRACT DOCUMENTS, OF WHICH THE CONTRACTOR FAILED TO NOTIFY THE ARCHITECT BEFORE CONSTRUCTION AND/OR <br />FABRICATION OF THE WORK. <br />5. THE ARCHITECT/ENGINEERSHALL NOTBERESPONBIBLE FOR THESAFETY AND CONSTRUCTION PROCEDURES, TECHNIQUES, <br />OR THE FAILURE OF THE BUILDER TO CARRY OUT THE WORK IN ACCORDANCE WITH THE DRAWINGS OR THE REQUIRED CODES. <br />6. THE STRUCTURAL DESIGN IS BASED ON THE INTERACTION OF ALL PARTS OF THE COMPLETED BUILDING. THE CONTRACTOR <br />SHALL SOLELY BEAR THE RISK FOR PROVIDING ADEQUATE STABILITY AND SAFETY OF THE STRUCTURE DURING <br />CONSTRUCTION UNTIL PERMANENT MEMBERS ARE COMPLETELY INSTALLED. <br />7. DETAILS SHOWN ON THE DRAWINGS ARE TO BE CONSIDERED TYPICAL FOR ALL SIMLAR CONDITIONS. <br />8. THE CONTRACTOR SHALL MAKE NO STRUCTURAL CHANGES WITHOUT WRITTEN APPROVAL FROM THE ARCHITECTIENGINEER. <br />9. NO STRUCTURAL MEMBERS ARE TO BE CUT FOR PIPES, DUCTS, ETC. UNLESS SPECIFICALLY DETAILED. <br />GARAGES AND CARPORTS <br />1. GARAGEDOOR <br />A. ENGINEERED FOR MIN. WIND LOAD, LISTED ON COVER SHEET <br />B. DETAIL TO BE SUPPLIED BY GARAGE DOOR SUPPLIER <br />C. DETAIL TO BE ATTACHED TO PERMIT PACKAGE BY BUILDER <br />2. AS PER SECTION R3025.1:OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTOA ROOM USED FOR SLEEPING <br />PURPOSES SHALL NOT BE PERMITTED. OTHER OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALLBE EQUIPPED WITH <br />SOUD WOOD DOORS NOT LESS THAN 13/B INCHES IN THICKNESS, SOLID OR HONEYCOMB CORE STEEL DOORS NOT LESS THAN <br />13B INCHES THICK, OR 20-MINUTE FIRE -RATED DOORS. <br />3. AS PER SECTION R302.5.2: DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEIUNGS SEPARATING THE <br />DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM NO.28 GAGE (0.481"SHEET STEEL V MIN. RIGID <br />ON -METALLIC CLASS OR CLASS 1 DUCT BOARD OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE <br />GARAGE. <br />4. AS PER SECTION R302.8 & TABLE R3028: THE GARAGE SHALL BE SEPARATED FROMTHE RESIDENCE AND ITS ATTIC AREA BY NOT <br />LESS THAW% -INCH GYPSUM BOARD APPLIED TO THE GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMS SHALL BE <br />SEPARATED FROM ALL HABITABLE ROOMS ABOVE BY NOT LESS THAN 5 /8-INCH TYPE X GYPSUM BOARD OR EQUIVALENT. <br />WHERE THE SEPARATION IS A FLOOR -CEILING ASSEMBLY, THE STRUCTURE SUPPORTING THE SEPARATION SHALLALSO BE <br />PROTECTED BY NOT LESS THAN 1/2-INCH GYPSUM BOARD OR EQUIVALENT. <br />SnWORK <br />1. REFER TO THE SOILS REPORT FOR SPECIFIC DESIGN REQUIREMENTS (IF REQUIRED BY BUILDING DEPARTMENT), <br />2. REFER TO THE CIVIL DRAWINGS FOR LOCATION OF BUILDING WORKING POINTS, ROUGH GRADING, ONSITE UTILITIES, <br />SITE IMPROVEMENTS, SITE RETAINING WALLS, AND SPECIFIC GENERAL NOTES, THE SOILS REPORT AND CIVIL <br />DRAWINGS SHALL OVERRIDE CONFLICTS WITH SITE WORK NOTED HEREIN.SEE LANDSCAPE DRAWINGS FOR FINAL <br />FINISH GRADES, PLANTING AND IRRIGATION. <br />3. ELEVATIONS SHOWN ON THE SITE DRAWINGS ARE MINIMUM REQUIRED DEPTHS, IF DIFFERENT CONTACT THE <br />ARCHITECT. <br />4. NO EXCAVATION SHALL BE MADE WHOSE DEPTH BELOW THE FOOTING IS GREATER THAN''/: THE HORIZONTAL <br />DISTANCE FROM THE NEAREST EDGE OF THE FOOTING, <br />5. ALL BACKFEL AT STRUCTURES, SLABS, STEPS, AND PAVEMENTS SHALL BE CLEAR OF GRANULAR FILL. PLACE IN S' <br />LAYERS AND COMPACT TO 95%MAXIMUM DRY DENSITY DETERMINED IN ACCORDANCE WITH ASTM D1557. THE <br />BUILDING SITE SHALL BE KEPT DRY SO THAT EROSION WILL NOT OCCUR IN THE FOUNDATIONS. <br />6. COMPACTION BY FLOODING OR JETTING IS STRICTLY PROHIBITED. <br />7. DO NOT BACKFILL UNTIL SLABS HAVE CURED OR HAVE BEEN PROPERLY BRACED. (WHERE APPLICABLE) <br />8. EXCAVATIONS TO BE A MINIMUM OF 3'- 0' BEYOND NEW FOOTING LINE. <br />9. THE GENERAL CONTRACTOR MUST TAKE MEASURES TO CONTROL SOIL EROSION AS PER ALL LOCAL AND STATE <br />REQUIREMENTS. <br />10. THIS BUILDING IS NOT DESIGNED TO BE CONSTRUCTED WITHIN A FLOOD ZONE, UNO. CONTRACTOR IS TO VERIFY THE <br />ELEVATION OF THE FINISHED FLOOR SLAB WITH THE SIGNED AND SEALED SURVEY WHICH COMPLIES WITH ALL LOCAL <br />CODES HAVING JURISDICTION, INCLUDING ALL APPLICABLE STATE, CTTY,AND COUNTY BUILDINGAND ZONING CODES. <br />11. SWIMMING POOL, DECK, SPA, AND ASSOCIATED WORK IS TO BE PERMITTED SEPARATELY BY ENGINEERED SHOP <br />DRAWING. <br />12. TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING SOIL APPLIED PESTICIDES, <br />BAITING SYSTEMS AND PESTICIDES APPLIED TO WOOD, OR OTHER APPROVED METHODS OF TERMENT PROTECTION <br />LABELED FOR USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION. UPON COMPLETION OF THE <br />APPLICATION OF THE TERMITE PROTECTIVE TREATMENT, A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE <br />BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: <br />'THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. <br />TREATMENT IS IN ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF <br />AGRICULTURE AND CONSUMER SERVICES." <br />T� <br />1. ALL WOODS AND WOOD CONSTRUCTION SHALL COMPLY WITH SPECIFICATIONS AND CODES MODIFICATIONS AS SPECIFIED <br />HEREIN: <br />A. AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (STANDARDS MANUAL) <br />B. NATIONAL FOREST PRODUCTS ASSOCIATION: <br />I. NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION <br />C. SOUTHERN PINE INSPECTION BUREAU: <br />1. STANDARD GRADING RULES FOR SOUTHERN PINE LUMBER <br />D. TRUSS PLATE INSTITUTE: <br />I. NATIONAL DESIGN STANDARDS FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES(TPI-2002) <br />E. APA- THEENGINEEREDWOODASSOCIATION: <br />1. ENGINEERED WOOD CONSTRUCTION GUIDE <br />F. AMERICAN WOOD PRESERVERS ASSOCIATION STANDARDS <br />2. ALL LUMBER EXPOSED TO WEATHER OR AGAINST SOIL, CONCRETE OR MASONRY MUST BE PRESSURE TREATED. <br />3. MNIMUM NAILING PER CHAPTER 6- WALL CONSTRUCTION AND TYPICAL NAILING SCHEDULE ON PLANS. <br />4, NOTCHING OR CUTTING OF FRAMING MEMBERS SHALLCOMPLY WITH CHAPTER & WALL CONSTRUCTION. <br />5. WALL SHEATHING SHALL BE PER STRUCTURAL, SEE ROOFIWALLIFLOOR SHEATHING FASTENER SCHEDULE ON SHEET SN1. <br />6. MINIMUM DIMENSION OF ANY PLYWOOD SHEET SHALL BE 24'AND THE MINIMUM AREA SHALL BE 8 FT .SQ. <br />PLL MMING <br />1. SANITARY LINES SHALL BE OF CAST IRON OR PVC (SCHEDULE 40) AS APPROVED BY THE BUILDING OFFICIAL <br />2. WATER SUPPLY LINES SHALL BE CPVC OR UPONOR PEX'A' (CROSS -LINKED POLYETHYLENE) WITH F1960 FITTINGS. <br />3. CONDENSATION LINES SHALL BE MINIMUM %' PVC (SCHEDULE 40), INSULATED WITH W AMAFLEX. <br />4. SHOWER HEADS SHALL HAVE A FLOW CONTROL DEVICE TO GIVE A MAXIMUM FLOW OF 3 GPM EACH. <br />5. ALL CLEANOUTS SHALL BE FLUSH WITH GRADE. <br />6. NO VENT STACKS SHALL PASS THROUGH ROOF CRICKETS, VALLEYS, OR RIDGES. <br />7. SIZE AND LOCATION OF CLEANOUTS SHALL CONFORM TO SECTION P3005.2 <br />8. FIXTURE SUPPLY SIZES SHALL CONFORM TO SECTION P2903, <br />9. THE PLUMBER IS TO DIVERT ALL VENTS TO REAR ELEVATION WHEN POSSIBLE. <br />10. DRILLING & NOTCHING OF WOOD FRAMED STRUCTURAL MEMBERS SHALL FOLLOW PROVISIONS OF SECTION P26D3.2. <br />EXTERIOR WALL COVERMOS <br />1. ALL EXTERIOR WALL COVERINGS AND SOFFITS SHALL BE CAPABLE OF RESISTING THE DESIGN PRESSURES SPECIFIED FOR <br />THE WALLS FOR COMPONENTS AND CLADDING LOADS IN ACCORDANCE WITH TABLE R301.2(2) AS MODIFIED BY TABLE <br />R301.2(3), MANUFACTURED SOFFITS SHALL BE TESTED AT 1.5 TIMES THE DESIGN PRESSURE <br />EXTERIOR FINIQBEM <br />1. WHEN PLASTERING WITH CEMENT, PLASTER SHALL NOT BE LESS THAN THREE COATS, gib' THICK, OVER FRAMED WALLS <br />APPLIED OVER PAPER BACKED METAL LATH OR WIRE FABRIC LATH AND WITH TWO LAYERS OF VAPOR BARRIER, NOT LESS <br />THAN 2 COATS, 12" THICK, WHERE APPLIED OVER MASONRY OR CONCRETE. <br />2. STUCCO OR PORTLAND CEMENT PLASTER SHALL BE INSTALLED, PROPORTIONED AND MIXED IN ACCORDANCE WITH <br />ASTM-C926 & ASTM-C1063.12a <br />3. LATH & ACCESORIES PER ASTM-C-1D63.1IA & R703.7.1. ALL STUCCO APPLICATION DETAILS, INCLUDING BUT NOT LIMITED TO: <br />- ALL STUCCO CONTROL JOINTS - KICK -OUT DETAILS <br />- 'L' FLASHING - HORIZONTAL LATH AND PAPER DETAILS <br />- PIPE PENETRATION DETAILS - VENT PENETRATION DETAILS <br />- WEEP SCREED DETAILS - CONDUIT PENETRATION DETAILS <br />- CASING BEAD DETAILS - DRIP EDGE DETAILS <br />- CANTILEVER DRIP EDGE DETAILS - CORNER BEAD DETAILS <br />- WINDOW CASING DETAILS - STUCCO TO SIDING TRANSITION DETAILS <br />- WINDOW FLASHING DETAILS <br />4. SHALL BE INSTALLED PER ASTM-C1063 - 1 1A AND R703.7. <br />mORY OY'PMUM BOARD <br />UNDER STAIR PROTECTION: <br />1. ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER STAIR SURFACE AND ANY SOFFITS PROTECTED <br />ON THE ENCLOSED SIDE WITH 1/2' GYPSUM BOARD. R302.7. <br />.1 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32780 <br />PH: 407-774-6078 <br />FAX: 407.7744078 <br />www.abdesW%roup.mm <br />AA 8: 0003325 <br />amnr <br />ava0><v. ae Lozs <br />SILVERAD0 <br />LOT #10 <br />BLK. #11 <br />[PItOJECT <br />0 2-1 1 <br />MODSMA <br />4ENB <br />"1751-NEUVILLE" <br />GA tAGN awMO: <br />RIGHT <br />PAO)Q: <br />GENERAL <br />NOTES <br />150 MPH EXP. B <br />ROLAiC A ABOL <br />ARM YC4 J <br />DwT 10/23/18 <br />scAI.E. 1/4"=1*-O" <br />a swr <br />GN <br />