A
<br />OA&E-END
<br />HIP ROOF JF" w
<br />ROOF WIND DESIGN PRESSURES
<br />NET (GROSS) ASCE 7-1
<br />ZONE 1 = 5.97 PSF (19.97)
<br />ZONE 2 = 17,98 PSF (27.98)
<br />ZONE 3 = 33.53 PSF (43.53)
<br />'A"- C-0" END ZONE DISTANCE
<br />BASIC WIND SPEED: 150 MPH
<br />WIND EXPOSURE:"B"
<br />RISK CATAGORY: II
<br />APPLICABLE INTERNAL
<br />PRESSURE COEFFICIENT +-0.18
<br />ROOF DMWMAGM
<br />FOR ASPHALT SHINGLE ROOF, USE MIN 7/19'
<br />O.S.B. OR 1/2" CDX EXT. PLYWOOD, FOR
<br />CEMENTITIOUS TILE AND METAL ROOFING, USE
<br />MIN, 5/8 CDX EXT. PLYWOOD, WTH 8d RING
<br />SHANK GUN NAILS AT 4" O.C. AT SUPPORTED
<br />PANEL EDGES AND 8d RING SHANK GUN NAILS
<br />AT 8" O.C. AT INTERMEDIATE SUPPORTS. SEE
<br />DETAIL
<br />ROOF SHEATHING TO GABLE END FRAME USE
<br />8d GUN NAILS 0 4" O.C. EDGEWISE 2x4
<br />BLOCKING ALL PANEL JOINTS W/ IN W OF GABLE
<br />END.
<br />ROOF/ WALL/ FLOOR
<br />SHEATHING
<br />FASTENER SCHEDULE
<br />NAIL SCHEDULE
<br />SIZE
<br />TYPE
<br />MIN. LENGTH
<br />MIN. DIA
<br />SHANK
<br />TENSILESTR.
<br />SHANK
<br />8d
<br />RING SHANK
<br />2 12'
<br />0. 120'
<br />170,000
<br />RING
<br />SCREW SHANK
<br />(18.20 RINGS
<br />PER INCH)
<br />8d
<br />SCREW SHANK
<br />2 12'
<br />0.129'
<br />PNEUMATIC
<br />SCREW-MNLS
<br />1. NAIL SIZE PER ASTM F1884
<br />2. INTERNATIONAL STAPE, NAIL 8 TOOL
<br />ASSOCIATION (ISANTA) ESR-1539
<br />EXTERIOR WMEATHI M1
<br />USE 1/2" CDX OR 7116" O.S.B. PLY WITH 8d RING
<br />SHANK GUN NAILS AT 4" O.C. AT PANEL SIDES
<br />AND Sd RING SHANK GUN NAILS 4" O.C. TOP 8
<br />BOTTOM PANEL AND 8d RING SHANK GUN
<br />NAILS AT S' O.C. AT INTERMEDIATE SUPPORTS
<br />OR 7/16" ZIP SHEATHING SYSTEM (INSTALLED
<br />PER MANUF. SPECS.) SEE DETAIL.
<br />8d RING SHANK GUN NAILS @ 4" O.C.
<br />TOP & BOTTOM EDGES
<br />z W .
<br />2
<br />.
<br />M3 G
<br />a
<br />a
<br />z
<br />K �
<br />�
<br />1
<br />Z 3
<br />aJ
<br />$ L)
<br />N N
<br />m
<br />TOP CORD BLOCKING AT 4'
<br />O.C. MAX. IN FIRST 2 FRAMING
<br />SPACES AT EACH ENO.
<br />oAMF cER ORTRUSS -�`
<br />ROOF SHEATHING LAYOUT
<br />AND ENDWALL BRACING
<br />FOR GABLE END FRAM M
<br />Bd RING SHANK GUN NAILS
<br />8" O.C. IN FIELD'
<br />8d RING SHANK GUN NAILS O 12' O.C. IN
<br />FIELD or 8d x 2 12' SCREW SHANK
<br />PNEUMATIC SCREW -NAILS C 12.O.WN
<br />FIELD J\
<br />TYP. 3/4" T&G SUB -FLOOR DECKING GLUED TO ALL EXPOSED MEMBERS
<br />STRUCTURAL. DRAWINGS SHALL BE USED IN CONJUNCTION WTH JOB SPECIFICATIONS AND
<br />ARCHTECTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND SITE DRAWINGS. CONSULT
<br />ARCHTECTURAL DRAWINGS FOR SLEEVES, DEPRESSIONS, AND OTHER DETAILS NOT SHOWN
<br />ON STRUCTURAL DRAWINGS. APPLICABLE BUILDING CODE STANDARDS: FBCR 2017, SIM EDITION
<br />ACI 318-14, BUILDING CODE REQUIREMENTS
<br />FOR STRUCTURAL CONCRETE, ACI 530-13/ASCE 5-13 AISI SPECIFICATION FOR THE DESIGN OF
<br />COLD -FORMED STEEL STRUCTURAL MEMBERS 2011. ASCE 7-10 ANDAISC SPECIFICATIONS
<br />ALL DETAILS AND SECTIONS SHOW ON THE DRAWINGS ARE INTENDEDTO BE TYPICAL AND
<br />SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE ON THE PROJECT,
<br />EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN.
<br />ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD. DO NOT SCALE THE
<br />DRANPDS. FOLLOW WRITTEN DIMENSIONS ONLY. ANY DISCREPANCIES SHALL BE BROUGHT
<br />TO THE ATTENTION OF THE ARCHITECT PRIOR TO PROCEEDING WITH THE AFFECTED PART
<br />OF THE WORK.
<br />THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND STABLE AFTER THE BUILDING
<br />IS COMPLETE. IT 18 THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES ADD
<br />SEQUENCES TO INSURE SAFETY OF THE BUILDING AND ITS COMPONENTS
<br />DURING ERECTION. THIS WORK INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING,
<br />TEMPORARY BRACING, GUYS OR TIE-0OWNS.
<br />THE CONTRACTOR SHALL SUPPLEMENT THE MINIMUM REQUIRED FOUNDATION AND SITE PREPARATION
<br />REQUIREMENTS AND SLAB -ON -GRADE THICKNESS TO HANDLE CONSTRUCTION LOADS.
<br />ALL AGGREGATE USED IN CONCRETE SHALL CONFORM TO ASTM C33. MAXIMUM AGGREGATE SIZE SHALL BE 3/4'.
<br />PROVIDE 8%AIR ENTRAINED CONCRETE EXPOSED TO EARTH OR WEATHER
<br />WOOD:
<br />NON -BEARING WOOD WALLS TOP PLATES 8 STUDS CAN BE SPF.
<br />ALL EXPOSED EDGES OF CONCRETE ARE TO BE CHAMFERED 3/4'.
<br />ALL WOOD FOR BEAMS, BEARING WALLS, SOLE PLATES, TOP PLATES, BRAO NO, LEDGERS, BLOCKING,
<br />PROVIDE 6-MIL CONTINUOUS POLYETHYLENE VAPOR BARRIER MEMBRANE UNDER ALL SlAB50NGR01AOWFHE INDICATED ON
<br />CRIPPLERS, SI LLS, ETC., SHALL BE SOUTHERN PINE NO.2 OR BETTER.Fb- 1100 PSI AND A MODULUS OF
<br />DRAWINGS. SEAMS LAPPED C INCHES AND SEAL®WITH ADIESIVETAPE
<br />ELASTICITY = 1,400,000 PSI. ALL WOOD IN CONTACT WITH CONCRETE OR CONCRETE BLOCK SHALL BE
<br />PRESSURE TREATED. PRESSURE TREATED BOTTOM PLATE REQUIRED. WOOD FOR NONSTRUCTURAL USES
<br />FORMWORK:
<br />SHALL BE RATED TO RETENTION LEVELS OF 0.25 PCF OF A BORATE PRESERVARVE TREATMENT: DI SODIUM
<br />CORROBORATE TETRAHEDRAL (DOT). WOOD FOR STRUCTURAL USE THAT SHALL BE TREATED FOR ANY
<br />FORM -WORK, SHORING, AND BRACING FOR ALL CONCRETE BEAMS, SLAB$, COLUMNS, WALLS,
<br />REASON $HALL BE RATED TO RETENTION LEVELS OF 0.42 PCF FOR DOT OR MORE. NAILS, SPIKE, BOLTS USED
<br />AND FOOTINGS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE NTH AG 347,
<br />W/ DOT SHALL BE HOT DIPPED GAILY. FOR STRUCTURAL USES, AVOID BUYING TREATED LUMBER THAT
<br />'RECOMMENDED PRACTICE FOR CONCRETE FORMANORK.
<br />CONTAINS MORE THAN h•OF HEARTWOOD.
<br />EXCLUSIONS FROM THESE PLANS:
<br />MINIMUM NAILING PER FBCR 2017, BIN EDITION. SEE NAILING SCHEDULE ON PLANS.
<br />WATERPROOFING, FLASHING, SOUND ISOLATION, FIRE SEPARATION, OR OTHER NON STRUCTURAL ITEMS
<br />ARE NOT PART OF THE STRUCTURAL PLANS AS THEY ARE NOT CONSIDERED TO BE STRUCTURAL.DEPENDING
<br />PROVIDE SOLID BLOCKING UNDER ALL POINT LOADS AND WOOD COLUMNS WITH 2x STRUCTURAL LUMBER
<br />ON THE TYPE OF CONSTRUCTION THESE ITEMS SOME OR ALL MAY BE REQUIRED BUT ARE BY OTHERS.
<br />SYP #2.
<br />UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WITH CONCRETE. SEAT PLATES SHALL BE PROVIDED
<br />WELDED WIRE MEN,
<br />AT BEARING LOCATIONS WITHOUT WOODEN TOP PLATES.
<br />WELDED IN RE MESH, SHALL BE ASTM Al85, GRADE 85 AND BE PLACED IN ACCORDANCE WTH THE ACI
<br />WOOD TRUSSES:
<br />TYPICAL DETAILS. MINIMUM LAP SHALL BE ONE SPACE PLUS TWO INCHES. W RE MESH FOR SLABS SHALL BE
<br />SUPPORTED WITH 2• CHAIRS SPACED 3'-0" OC, EACH WAY.
<br />TODESIGNED AND FABRICATED IN ACCORDANCE WITH THE "NATIONAL DESIGN SPECIFICATIONS FOR
<br />STRESS -GRADE LUMBER AND ITS FASTENINGS' BY THE NFPA. TRUSS DESIGNS SHALL BE SIGNED AND
<br />SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN FLORIDA. SEE NOTED FOR SHOP DRAWINGS.
<br />DO NOT SCALE DRAWINGS. THE CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR RERWORCING STEEL: CONNECTOR PLATES SHALL BE A MINIMUM THICKNESS OF 0.038' AND BE MANUFACTURED FROM STEEL
<br />TO WORK PERFORMED AND SHALL NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND. REBAR SHALL BE ASTM A815 GRADE SO DEFORMED BARS, FREE FROM OIL, SCALE, AND RUST AND PLACEDIN MEETING THE REQUIREMENTS OF ASTM A448, GRADE A. AND SHALL BE HOT-DPPEDGALVANZEO.
<br />ACCORDANCE W THE TYPICAL BENDING DIAGRAM AND PLACING DETAILS OF THE ACI STANDARDS AND
<br />DESIGN LOADS: SPECIFICATIONS. CONTRACTOR SHALL SUBMIT REBAR SHOP DRAWINGS FOR REVIEW PRIOR TO DESIGN, FABRICATE, AND ERECT WOOD TRUSSES IN ACCORDANCE NTH TPI-14, "DESIGN NATIONAL
<br />FABRICATION. HORIZONTAL AND VERTICAL BARS SHALL LAP 8 x BAR NO. UNSCHEDULED FIELD LAPS ARE STANDARDS FOR METALPLATELONNECTED-WOOD TRUSS CONSTRUCTION:, ADD 'TPINYTCA SCSI 1"
<br />ROOF: LIVE LOAD FLOOR LIVE LOAD 40 SUBJECT TO ENGINEER'S REVIEW. COMMENTARY AND RECOMMENDATIONS FOR HANDLING, INSTALLATION BRACNG METAL43LATECONNECTED
<br />PM TYP. MIN LAPS SHALL BE AS FOLLOWS: #4 BAR - 25" #S BAR - 3S' WOOD TRUSSES.
<br />20 paT TOP CHORD non<alculrent
<br />10 psf BTM CHORD-ronCalcVr INA
<br />DEADLCAD DEAD LOAD
<br />15 pd TOP CHORD 20 psf TOP CHORD
<br />(7 psf W/ ASPHALT SHINGLES) (10 PSI W/ No GYPCRETE)
<br />10 psf BTM CHORD 5 PSf STM CHORD
<br />DEAD LOAD TO RESIST W ND UPLIFT: 1 Opsf
<br />BALCONY LIVE LOAD 80 psf
<br />WIND DEAD LOAD SPEED-160 MPH 3-SECOND GUST
<br />(ASCE 7-10 (FBC R2017) EXPOSURE B, RISK CATEGORY 11)
<br />SHOP DRAWING REVIEW:
<br />SHOP DRAWINGS WILL BE REVIEWED FOR GENERAL COMPLIANCE WITH THE DESIGNING INTENT
<br />OF THE CONTRACT DOCUMENTS ONLY. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
<br />COMPLIANCE WTH THE CONTRACT DOCUMENTS AS TO QUANTITY, LENGTH, ELEVATIONS, DIMENSIONS, ETC
<br />ALL SHOP DRAWINGS SHALL BE REVIEWED BY THE CONTRACTORS PRIOR TO SUBMITTAL TO
<br />THE ARCHTECT. DRAWINGS SUBMITTED WITHOUT REVIEW WILL BE RETURNED UNCHECKED.
<br />SHOP DRAWINGS IN THE FORM OF REPRODUCIBLE SEPIAS OF STRUCTURAL DRAWNGS (CON-
<br />TRACT DOCUMENTS) ARE PROHIBITED WITHOUT THE EXPRESS WRITTEN PERMISSION FROM
<br />THE ENGINEER.
<br />IN ALL INSTANCES, THE CONTRACT DOCUMENTS WILL GOVERN OVER THE SHOP DRAWNGS
<br />CHECKED, UNLESS OTHERWISE SPECIFIED IN WRITING BY THE ARCHITECT.
<br />FOUNDATIOW SITE PREPARATION:
<br />FOOTINGS WERE DESIGNED FORAN ALLOWABLE SOIL BEARING PRESSURE OF 2,000 PSI,
<br />FOOTING EXCAVATIONS AND SLAB SUB -GRADE SHALL BE COMPACTED TO A DRY DENSITY
<br />OF AT LEAST 95% OF THE MODIFIED PROCTOR MAXIMUM DRY DENSITY, DETERMINED IN
<br />ACCORDANCE WITH ASTM D-1557. TREAT ALL SOIL FOR TERMITE PROTECTION,
<br />THE OWNER SHALL RETAIN THE SERVICES OF AN INDEPENDENT GEO-TECHNICAL ENGINEER
<br />TO VERIFY SUCCESSFUL COMPLETION OF SITE PREPARATION EFFORTS. LOCATIONS
<br />FAILING TO MEET THE GEO-TECHNICAL ENGINEERS REQUIREMENTS SHALL BE RECOMPACTEDAND
<br />RETESTED AT THE CONTRACTORS EXPENSE, AND AS DIRECTED BY THE ARCHITECT. WRITTEN
<br />CERTIFICATION THAT THE MINIMUM DESIGN BEARING CAPACITY, AND THAT THE COMPACTION
<br />REQUIREMENTS HAVE BEEN MET SHALL BE MADE BY THE GEO-TECH. ENGINEER.
<br />CONCRETE SHALL ACHIEVE MINIMUM 28 DAY COMPRESSIVE STRENGTHS AS FOLLOWS:
<br />2,500 PSI REGULAR WEIGHT FOR FOOTINGS, AND SLABONGRADE
<br />3,000 PSI REGULAR WEIGHT FOR BEAMS, COLUMNS, AND 5" STRUCTURAL TERRACE SUS
<br />CONTRACTOR S-AL SUBMIT PROPOSED MX DESINS WITH HISTORICAL STRENGTH DATA
<br />FOR EACH SEPARATE MIX PRIOR TO CONCRETE PLACEMENT. CONCRETE SLUMP SHALL
<br />NOT EXCEED S * PRIOR TO THE ADDITION OF PLASTICIZER
<br />CONCRETE SHALL COMPLY NTH ALL THE REQUIREMENTS OF ACI 301 AND ASTM C44 OR
<br />MEkWRN G, MANG, TRANSPORTING, ETC. CONCRETE TICKETS SHALL BE TMIESTAMED
<br />WHEN CONCRETE IS BATCHED. THE MAXIMUM TIME ALLOWED FROM WHEN WATER IS ADDED
<br />TO THE MX UNTIL IT IS DEPOSITED IN ITS FINAL POSITION SHALL NOT EXCEED 90 MINUTES.
<br />IF FOR ANY FEASGN THERE IS A DELAY IN SUCH THAT A BATCH IS HEW FOR LONGER THAN
<br />90 MNUTES THE CONCRETE SHALL NOT BE PACED. IT 94ALL BE THE RESPONSIBILITY OF
<br />THE TESTING LABCRATCRY TO NOTIFY THE OWNERS REPRESENTATIVE AND THE CONTRACTOR OF ANY NON COMPLIANCE WTH THE
<br />ABOVE
<br />REQUIRED CONCRETE COVERAGE OVER REBAR SAL. BE AS FOLLOWS
<br />A 3" FOR CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH( (FOUNDATIONS)
<br />8. FOR CONCRETE EXPOSED TO EARTH ANC40RWEATHER
<br />1-11TFOR M AD SMNLER
<br />2' FOR#B AND LARGER
<br />C. FOR CONCRETE NOT EXPOS TOVFATHER
<br />3/4' FOR SLABS WALLS AND JOISTS
<br />142" FOR BEAM AND COLUMN PRIMARY REINFORCEMENT, TIES, STIRItU S
<br />#5 BAR - 37' #7 BAR - 4Z'
<br />PROVIDE 36'. 38' CORNER BARS, BOND BEAM ONLY, LAPPED ADD TIED TO EACH BEAM REBAR, SEE DETAILS
<br />TRUSS MANUFACTURER WILL PROVIDE CALCULATIONS INOICA.TING ADDITIONAL DEAD LOADS FOR THE ROOF
<br />FOR ADDITIONAL INFORMATION.
<br />LOCATIONS WITH GUSSETS, CRICKETS AND VALLEY LOCATIONS REQUIRING ADDITIONAL ROOF FRAMING FOR
<br />ALL VERTICAL REINFORCING BARS IN CMU CELLS SHALT. BE ANCHORED IN THE FOOTING,
<br />INTERSECTIONS OF HIGHER OR LOWER ROOFS IN ACCORDANCE WTHANSI A58.1-1982.
<br />THICKENED SLAB, BEAM OR LINTEL SUPPORTING THE WALL AT THE TOP AND BOTTOM WITH
<br />HURRICANE STRAPS SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTRUCTIONS.
<br />MINIMUM 10 INCH HOOKS OR BENDS AND SHALL BE CONTINUOUS THROUGHOUT THE HEIGHT OF THE
<br />WALL.
<br />CONTRACTOR SHALL SUBMIT SIGNED AND SEALED DRAWINGS FOR ALTERNATE CONNECTION DETAILS AT
<br />TRUSSES/GIROERS TO COLUMNS AND WALLS FOR APPROVAL,
<br />RUN REINFORCING BARS CONTINUOUSLY LAPPED AT SPLICES AND AROUND CORNERS. DOWEL
<br />INTO INTERSECTING WALLS AND HOOK AT ENDS. STAGGER SPLICES WHEREVER POSSIBLE.
<br />ROOF 8 FLOOR LAYOUTS PROVIDED ON THESE PLANS ARE TO BE USED AS A GUIDE FOR BEARING
<br />DETERMINATIONS, FEASIBILITY 8 ARCHTECTURAL AIDE. TRUSS MANUFACTURER IS RESPONSIBLE FOR FINAL
<br />DO NOT CUT OR DISPLACE REINFORCING STEEL TO ACCOMMODATE THE INSTALLATION OF EMBEDDED ITEMS
<br />LAYOUT, SPANS 8 ALL TRUSG/ HEADER ENGINEERING. ANY DISCREPANCIES FROM THESE LAYOUTS THAT
<br />WTHOUT THE APPROVAL OF THE ENGINEER.
<br />AFFECT THE STRUCTURAL BEARING AS CALLED OUT ON THESE PLANS SHALL BE NOTIFIED TO THE
<br />STRUCTURAL ENGINEER OF RECORD PRIOR TO MANUFACTURE OF TRUSSES. THE TRUSS FABRICATOR SHALL
<br />MASONRY'
<br />PROVIDE ENGINEERED SHOP DRAWNGS OF EACH INDIVIDUAL TRUSS AND FULLY DIMENSIONED ERECTION
<br />MASONRY CONSTRUCTION AND MATERIALS SHALL CONFORM WITH ALL REQUIREMENTS OF THE
<br />PLAN SHOW NO COMPONENT LAYOUT. SHOP DRAWINGS SHALL BE SIGNED AND SEALED BY A FLORIDA
<br />"SPECIFICATION MASONRY STRUCTURES" (ACI 530/ ASCE 57TMS 402, BUILDING CODE REQUIREMENTS FOR
<br />LICENSED PROFESSIONAL ENGINEER.
<br />MASONRY STRUCTURES AND SPECIFICATIONS FOR MASONRY STRUCTURES AND COMMENTARIE%AS
<br />THE HURRICANE STRAPS SPECIFIED ON THE WALL SECTIONS AND PLANS ARE PROVIDED TO FAOUTATE THE
<br />PUBLISHED BY THE MASONRY STANDARDS JOINT COMMITTEE.
<br />CONSTRUCTION SCHEDULE, AND MAY CHANGE PREDICATED ON THE TRUSS AND GIRDER REACTIONS
<br />ALL BLOCK WALLS SHALL BE TWO -CELL HOLLOW CONCRETE MASONRY REGULAR SIZE BLOCK
<br />PROVIDED BY THE TRUSS ENGINEER
<br />MANUFACTURED IN CONFORMANCE NTH ASTM C90, GRADE f. - 1500 PSI. BLOCK SHALL BE PLACED USING
<br />Tiff TRUSS TO STRUCTURE CONNECTIONS AND LOADS SPECIFIED ON THIS PLAN SHALL SUPERCEDE THOSE
<br />RUNNING BOND UNLESS OTHERW SE NOTED. LAY1UP MASONRY WALLS TO BOTTOM OF TIE BEAMS BEFORE
<br />OF THE DELEGATED TRUSS ENGINEER, WIND UPLIFT VALUES HAVE BEEN BASED ON ASCE 7-10 COMPONENT
<br />PLACING CONCRETE FOR IN -WALL COLUMNS. GROUT USED TO FILL MASONRY CELLS SHALL COMPLY WTH
<br />AND CLADDING W ND LOAD PRESSURES. THE DELEGATED TRUSS ENGINEER SHALL BE RESPONSIBLE FOR
<br />ASTM C-478, AND SHALL PROVIDE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS, UNLESS
<br />ALL TRUSS TO TRUSS CONNECTIONS.
<br />SPECIFICALLY NOTED OTHERWISE ON FOUNDATION PLAN. THE GROUT MIX SHALL HAVE A MAXIMUM 3/8"
<br />ALL SHEET METAL FRAMING CONNECTORS SHOWN ON THE PLANS SHALL "LISP STRUCTURAL
<br />COURSE AGGREGATE, AND SHALL BE PLACED W A SLUMP OF W TO W'. USE ONLY MECHANICAL VIBRATION
<br />CONNECTORS" BY UBP, OR EQUAL UNLESS NOTED OTHERWISE ON PLANS, INSTALL CONNECTIONS
<br />TO CONSOLIDATE GROUT.
<br />,
<br />WITH THE SIZE AND NUMBER OF BOLTS/NAILS AS RECOMMENDED BY THE MANUFACTURER IN THE
<br />TYPE 'M" OR "S" MORTAR SHALL BE USED EXCLUSIVELY ON THIS PROJECT. MORTAR SHALL BE
<br />LATEST CATALOG.
<br />PROPORTIONED AND MIXED AS OUTLINED UNDER ASTM C-270. HORIZONTAL AND VERTICAL MORTAR JOINTS
<br />SHALL BE 3/8" THICK UNLESS OTHERWISE NOTED. REMOVE MORTAR PROTRUSIONS THAT EXTEND INTO
<br />CELLS TO BE FILLED.
<br />FILL CMU CELLS SOLID WTH GROUT AT ALL CELLS TO RECEIVE EXPANSION ANCHORS AND(OR VERTICAL
<br />REINFORCING.
<br />LAP VERTICAL REBAR 8 X BAR NO. (48 BAR DIAMETERS)., U.N.O
<br />STRUCTURAL STEEL:
<br />THE MATERIAL, FABRICATION, AND ERECTION OF STRUCTURAL STEEL SHALL COMPLY WITH THE
<br />SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS,
<br />9TH EDITION, BY THE. AMERICAN INSTITUTE OF STEEL CONSTRUCTION. STRUCTURAL STEEL SHALL BE ASTM
<br />ASS, Fy - 38 ksl FOR ANGLES, PLATES, AND WSHAPES. STRUCTURAL TUBING SHALL BE ASTM A500, GRADE B,
<br />Fy- 46 ksl. STRUCTURAL PIPE SHALL BE ASTM53, GRADE B, TYPE E OR S, Fy = 35 WI. TUBE AND PIPE
<br />COLUMNS SHALL BE CONCRETE -FILLED IN THE SHOP.
<br />ANCHOR BOLTS AT THE COLUMN BASES SHALL BE ASTM A307 BOLTS WITH DOUBLE -NUT LEVELING. ALL
<br />OTHER BOLTS SHALL BE ASTM A325-N BOLTS WTH WASHERS UNDER THE TURNED ELEMENT. BOLTS SHALL
<br />BE TIGHTENED IN ACCORDANCE WITH THE TURNGFF-THEINUT METHOD.
<br />ALL ANCHOR BOLTS SHALL BE GALVANIZED STEEL. JAOLTS ARE TO BE STEEL.
<br />FASTENER SCHEDULE
<br />WINDOW AND
<br />DOOR BUCK FASTENERS
<br />FASTENER
<br />APRIGTON
<br />TYPE
<br />SPAONG
<br />REMARK
<br />AFPU-
<br />elg
<br />TYPE
<br />I SPACING
<br />I RE-
<br />I-- TO
<br />RY/GONG.
<br />C EH DSNED Cdl
<br />NNL 111 LONG.
<br />B�
<br />OMPOEpOIXi B.1CK
<br />TO MASOMYAJDNC.
<br />SEE DETNL
<br />SEE DEfMI
<br />- SEE DETNL
<br />SEE DETO&
<br />SOD, N..IXT. DOORS
<br />CARE HVABNED COx
<br />a"OC
<br />WWDOW/OOORIFASTENED
<br />OMAGEDODRBI-CAL
<br />SEE DETNL
<br />SEE DETNL
<br />SEE DE-L
<br />SEE DETY
<br />1x PT, SEENOIE.
<br />NAIL 112 LONG
<br />STAGGER®
<br />HMO MAEONRVICONC.
<br />t0 MASJNRYICAw
<br />WEDOW BUCK
<br />CASEHARDEN®COIL
<br />S'CA:
<br />WNDOW/DOIXN FASTENED
<br />METAL 9TRAPro
<br />CONTACT THIS ENGINEER
<br />FOR SPACING
<br />I. PT. SEENOIE.
<br />NAL11/YLONG.
<br />BTAGOERED
<br />HMO MABONRrIWNG
<br />MASONRVICONL
<br />REQUIREMENTS
<br />E%f.9MNG DOOR
<br />(p 3lle'D!A
<br />?APCON'
<br />itl]'EMBB3.-
<br />NONBEN.WWWD
<br />ANB A'EMBE BO
<br />BULKh PT, SEENOTE.
<br />NO WA4IER
<br />fA611iA
<br />1TQt
<br />GIST., I IIT•®GEpST
<br />WALL TOCONC SLAB
<br />WAMIER BOLT 3f OE OIeT., 3• EOGEOST.
<br />h PTW Dow.Gx 0.1%°PAFx31l.' A"END. GIST., III
<br />PT TO STEEL COL., SEE W/_ER STAGGERED EDGE qBT.
<br />NOTE.
<br />tM
<br />1LES SHALL NOT BE USED FOR ANY STRUCTURAL APPLICATIONS
<br />2. FASTENING OF GARAGE DOORS, WINDOWS AND EXTERIOR SWING DOOR$ TO FRAMING BUCKS SHALL BE AS PER MANUFACTURER'S SPECS AND/OR NOA
<br />3. ALL FASCIA MATERIAL SHALL BE HAND FRAMED
<br />4. PAF SHALL BE HILT) X.ZF HEAVY DUTY PINS OR EQUAL SAME DIAMETER AS SPECIFIED HEREIN
<br />5, FASTENER SPACING FOR THE BUCKS SHALL BE THE STRICTER REQUIREMENT OF THE NOA OR THE SPACING DETAILED ABOVE
<br />8. WINDOW AND DOOR BUCKS SHALL BE AS WIDE OR WIDER AS THE DOOR OR WINDOW FRAME EXPECT FOR AN EXTERIOR SWING DOOR WITH WOOD DOOR FRAME. lx MEMBERS ARE NAILED AND
<br />2x MEMBERS ARE SECURED W/ TAPCONS OR PAF TO THE SUBSTRATE.
<br />1441 N. RONALD REAGAN BLVD.
<br />L.NGWOOD, FL 32750
<br />PH: 407-774.6078
<br />FAX: 407-774.4078
<br />www.abdosWigroup.com
<br />AA M: 0003325
<br />o�
<br />av
<br />N
<br />BUDDIV 89 JL40112�1SILVERALOT #1BLK. #
<br />PROJMCTp
<br />04128,002-10111
<br />MODMU 33
<br />4ENB
<br />N
<br />1751- NEUVILLE
<br />GA6W.AGa aMn140..
<br />RIGHT
<br />PAG>iC:
<br />DETAILS
<br />150 MPH EXP. B
<br />lAuWT l
<br />Dw� 10/23/18
<br />SCALE: i/4' 0"
<br />SiIL'>SCT
<br />s R