Laserfiche WebLink
FLOOR DECK <br />USP LFTAB W/(16)8d <br />COMMON NAILS, EACH <br />END EVERY STUD OR ON <br />EACH END OF "BUNDLE" <br />OF STUDS <br />PLYWOOD FLOOR <br />SHEATHING <br />USP LFTAB Wd <br />Ile, ad COM— usn .e <br />EACH END <br />FL#17244 <br />DBL PT 2x8 BLK'NG BETWEEN <br />TRUSSES W/ 10d 0 3- O.C. 1ST PLY <br />INTO LEDGER AND 10d 0 3' O.C. <br />STAGGERED UPPER PLY INTO 2.6 <br />BELOW <br />8" CMU WALL. — <br />REINF PER PLAN <br />Y 4"- <br />#8 WOOD SCREWS <br />NI <br />x 2" LONG 0 3" O.C.; <br />STAGGEREDDFF <br />CENTERLINEOFF2x6; <br />3/4" AS SHOWN <br />USP A3 EA <br />TRU <br />/4„ <br />NALNO PATTERN <br />08 WOOD SCREWS x 2' <br />LONG 0 3' O.C.; <br />STAGGERED <br />NI <br />AS SHOWN <br />DBL 2X8 LEDGER <br />TO CMU W/ 12" EXP. BOLT <br />AT 18" O.C. ANDS' FROM <br />NI <br />8" CMU WALL <br />END W/ MIN 5 -1/7' EMBED. <br />REINF PER PLAN <br />FLOOR DECK <br />PER ELEVATION/4" <br />LL Y <br />NAIL840 <br />PATTERN <br />= <br />0 ' <br />2x8 PT TERMINATION — -- - - <br />2x4STRONGBACK SECURED TO BLOCKING SECURED TO WALL -PRE-ENGINEERED WOOD <br />24" MA) <br />EACH TRUSS W/ (3)18d COMMON W/ (8) 3/16" ° x 4 TAPCON3 PRE-ENGINEERED WOOD 2x4 P.T. CEILING FLOOR TRUSSES (SEE <br />NAILS PROVIDE 2-TRUSS LAP 1X2 FIRE -STOP Fa FLOOR TRUSSES (SEE NAILER W/ FRAMING PLAN) <br />SPLICE LOCATED EITHER TOP OR FRAMING PLAN) MASONRY NAILS <br />DBL 2X_ LEDGER <br />BOTTOM OF FLOOR TRUSS, USP SPTH4/8PTH6 BTM. 0 12' O.C. <br />TYPICALLY 10'-0" BUT REFER TO PLATE STRAPS W/ iDd x 1 SEE SCHEDULE <br />TRUSS ENGINEERING FLOOR TRUSS OR 1/2" HOG NAILS FL#17238 SECTION DETAIL 1X2 FIRE -STOP DETAIL <br />GIRDER TRUSS <br />2x4 STRONGBACK, WALL / FLOOR FRAMING, AT TRUSSES BEARING AT TRUSSES PARALLEL <br />FLOOR BRACING 2 TRUSS PARALLEL TO WALL 3 ON EXTERIOR WALL 4 TO EXTERIOR WALL <br />PRE-ENG GABLE TRUSS <br />DBL PT 24 BLKNG BETWEEN <br />TRUSSES W/ 10d 0 3' O.C. 1ST PLY 2x4 BLOCKING BETWEEN TRUSSES <br />INTO LEDGER AND 10d 070C. .68 WOOD SCREWS AT FIRST TWO SAYS 4'-0° O.C. (AT <br />SHEATHING SEAMS)(BLOCKING PRE)02 <br />WOOD <br />STAGGERED UPPER PLY INT02x8 x 2" LONG 0 3" O.C.; NI NOT SHOWN FOR CLARITY) TRUSS SS(TY (TYP) 024" O.C. <br />BELOW STAGGERED OFF MAX <br />CENTERLINE OFF 2,6; <br />314" AS SHOWN <br />DBL 2X8 LEDGER <br />8" CMU WALL TO CMU W/ 12" EXP. BOLT NI <br />REINF PER PLAN AT 18" O.C. ANDS' FROM FOR STRAPPING <br />END W/ MIN 8-12" EMBED. VERIFY <br />PER ELEVATION FLOOR DE /4„ 6ECURE 2x8 PT. PLATE 70 BLK W/ TRUSS PLAN <br />LL W/ rZ' OIA. ANCHOR BOLT <br />w 2' 'Y^E <br />7 <br />O NALING PATTERN WASHER SET IN HIGH :y <br />N STRENGTH EPDXY B"MIN, <br />3 EMBED. AT 32" OC MAX <br />I SECURE GABLE T02xe P.T. <br />PFR Ft FvanON I �Y *? a PLATE W/ 12d's 8" O.C. MAX <br />24� 24„ MAX `PRE-ENGINEERED WOOD <br />2x4 P.T. CEILING FLOOR TRUSSES (SEE <br />NAILER W/ FRAMING PLAN) <br />MASONRY NAILS <br />17. O.C. <br />,X2 FIRE -STOP <br />X2 `. REPAIR DETAIL IF <br />LEDGER INSTALLED TOO LOW <br />AT TRUSSES PARALLEL <br />5 TO EXTERIOR WALL <br />SCALE: 3/4"=1'-0" <br />CONC. POURED <br />LINTEL COURSE <br />—CONT. 2x4 SECURED W/(2)10d's0 EACH <br />TRUSS TO BE INSTALLED 010-0" O.C. MAX <br />GABLE END BRACING W/ PRE-ENG <br />ABLE TRUSS @ CMU WALL <br />SCALE: <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407.774.4078 <br />W Ww.8bdeslgngroup.cDm <br />AA 8: 0003325 <br />avmn:v. ae Lom <br />SILVERADO <br />LOT #9 <br />BLK. # 12 <br />04128.002-09121 <br />MODZU <br />4EHB <br />"2605- HAYDEN" <br />GA %ARim 81111MM <br />RIGHT <br />PAGW. <br />DETAILS <br />150 MPH EXP. B <br />PIUNT 11/15D/18 <br />8CAlM 1/4"=1'-0" <br />S3.1B <br />