My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6866 Wagon Trail St
Zephyrhills
>
Building Department
>
Building Plans
>
6866 Wagon Trail St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 9:19:52 AM
Creation date
2/24/2025 9:56:36 AM
Metadata
Fields
Template:
Building Plans
Street #
6866
Location
Wagon Trail St
Contractor
D R Horton
Building Plans - Permit #
20885
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BACKER ROD <br />BACKER ROD <br />WIRE, LAYER 1, <br />STUCCO IIJfItAP <br />INSTALL 6' 6ELF-AD14ERMG <br />MEMBRANE FLASHING OVER <br />TOP, SIDES) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SEryIENCZ OF FLASHING TO BE. <br />I. BOTTOM. 2. 81DE8. 9. TOP <br />VENT CAP IS TO BE SET N BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT IS TO BE <br />TOOLED SO AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />JOINTS AND INTERSECTIONS <br />APPLY SEALANT AT PERIMETER OF <br />NON -MOVABLE FRAME AND STUCCO <br />vLL SIDE&& CAULKING • JOINT <br />A,DUND <br />PER SECTION R703.7 <br />EAwlor lathing and *xteft <br />Exterior use of portiand cement plaster <br />shall comply with the application <br />requirements of ASTM C 926.12A. <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1063-12A. <br />HOODED VENT <br />THICK, 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />WRB LAYER 4, FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />© DRYER <br />VENT (FRAME) <br />WOOD SHEATHNS <br />AIM LAYER 01, <br />STUCCO WRAP <br />tL*b LAYER 4, FORTIFIBER <br />BUILDING PAPER <br />WOOD — <br />CONSTUCTION <br />—METAL LATH <br />S' Cm VINYL CASING BEAD <br />Ai' RAISED BAND <br />V TON MID -WALL <br />eco wrecen <br />S' WIDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYING <br />Z FLASHING <br />STONE VENEER <br />OVER SCRATCH COAT <br />HORIZONTAL WEEP SCREED <br />W/STONE VENEER <br />(FRAME TO BLOCK <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER 02 (FORTIFIBER - - - -.- <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />WOOD SHEATHING <br />SELF-ADHESIVE FLASHING - — — — - <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R103.1.1 / ASTM C-54-1-0% MIN. 2.5 LBS. <br />PER 60. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />STUCCO <br />FINISH <br />6' SELF ADHESIVE <br />WOOD CONSTRUCTION <br />OVER TOP 4 SIDES <br />SELF <br />WOOD SHEATHING <br />Uk= SHEATHING <br />FLASHING <br />loe <br />WRB LAYER "I, <br />LAYER -1,UNIT <br />BTUCWRAP <br />STUCCO WRAP <br />$2 <br />LAYER 7, FORTIFIBER <br />PREMANUF. DRYER <br />BUILDING PAPER <br />VENT CAP (SET IN <br />METAL LATH <br />CONT. SEALANT) <br />WRB LAYER 02, FORTIFIBER <br />-FNISH�A <br />BUILDING PAPER <br />CONSTRICTIOND° <br />FASTEN TO WOOD STRICTURAL <br />SEALANT Ao <br />nWrIBER • T• Oc. MAX <br />TOP 4 SIDES <br />THICK, 3 COAT CEMENT <br />®' Aa u i <br />P <br />PLASTER <br />Vro K' MID_nu L <br />_ �UJEEP aCRE[D <br />CGB DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' <br />PIPE THROUGH / <br />WALL x\` <br />1 <br />b' SELF ADHESIVE— <br />FLASHMG (INSTALL <br />PER MANUF. SPECS-) <br />BUILDING PAPER — <br />UNDER 'QUICK FLASH' <br />ELEC. METEF <br />VERIFY LO <br />V TO Ya' MID -WALL <br />WEEP SCREED <br />�-6' SELF-ADHESIVE <br />FLASHING <br />WOOD FRAMED <br />I- — — — -I WALL <br />HORIZONTAL WEEP SCREED <br />(FRAME TO FRAME <br />A VENT PENETRATION <br />SCALE: N TA. <br />KRCfi I,—, r%Mt11=IYC <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />-('GREAT STUFF' OR SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />PROVIDE STUCCO SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED WOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LAYER el, <br />STUCCO WRAP <br />WOOD SHEATHING <br />APPROVED <br />WOUSEWRAP <br />BELOW <br />CUT SUCH TWA <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY TO FAA <br />EDGE <br />APPLY E-Z <br />OVER b® MI <br />GRADE 'D' <br />FELT-PROVI <br />SEALANT AT <br />JOINTS AND <br />INTERSECTIC <br />STEP #1 <br />5T F) #3 <br />1 <br />6' UNDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MASONALY BEFORE APFLYING <br />- - V.... ----- FNI*4 • MASONRY <br />7B HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK <br />S' <br />UIRB LAYER 01, — <br />STUCCO WRAP <br />CUT 'X' INTO <br />SELF -ADHERING <br />MEMBRANE FLASHING <br />\ <br />APPLY SELF -ADHERING <br />MEMBRANE FLASHING <br />OVER BOX AND OVER <br />APPROVED WRB LAYER <br />ry <br />STEP <br />#2 <br />WRB LAYER *I, <br />STUCCO WRAP <br />APPLY bm MIN <br />SEE <br />GRADE 'D' FELT <br />MEMBRANE FLASHING <br />OVER <br />SELF -ADHERING <br />FLASHING OVER <br />APROVED <br />HOUSEWRAP <br />WRB LAYER 02, FORTIFIBER <br />BUILDING PAPER <br />STEP <br />#4 <br />id <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ G.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />METAL LATH <br />STEP 05 STEP Oro <br />OELECTRICAL RECEPTACLE <br />1441 N. RONALD REAGAN BLVD <br />LONGWOOD, FL 32750 <br />PH: 407-774.6078 <br />FAX, 407-7744078 <br />www.abdoeigngroup.com <br />AA #: 0003325 <br />�a <br />e0DIV. Ae LOT: <br />SILVERADO <br />LOT 13 <br />BLK 11 <br />PROJECT/ <br />04128.002-13111 <br />MODEL: <br />4ENB <br />"1751— NEUVILLE" <br />GARAGE DWING: <br />LEFT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />150 MPH EXP. B <br />PRIP" <br />DATM 11/15/18 <br />scram: 1/4"=1'-O" <br />SHEET <br />WA2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.