Laserfiche WebLink
3"" <br />28'-B" <br />' <br />— — FM-12X12 — — <br />— <br />1 <br />— <br />— — — — --12X18 — — <br />FM <br />— — — <br />IN <br />1.1 <br />4" CONC. 4 <br />I' <br />W $ SLAB <br />w <br />ILL <br />ya *3 1/2 �F-24X24 <br />10'-0" 10 <br />1.1 <br />1 <br />I- 1 <br />FM-12X18 EXTEND <br />1.1 <br />1.1 <br />I <br />i <br />SLAB 1 1/2" <br />I . <br />I <br />I <br />I <br />I <br />I <br />T-- <br />I <br />SLAB <br />' <br />I <br />I <br />IX <br />I' <br />I <br />ILL <br />I <br />I <br />•I <br />19'-0" <br />5'-0" <br />15'-8" <br />I <br />I <br />I 1 <br />4" PVC <br />I <br />CHASE <br />1 <br />TE-1 <br />_ J <br />112-8" <br />4-5 1/2 <br />` <br />I <br />I <br />I <br />I <br />N <br />I <br />1 <br />EXTEND <br />I <br />1 1 <br />SLAB 1 1/2" <br />2 <br />I <br />14 CONC. �1 m FM-12X18 <br />, SLAB w WI 91.. <br />m <br />1 x <br />1.1 <br />I <br />Oa <br />3 1/2 N I f I <br />3'-4"op <br />I <br />2 <br />-7 tl2 <br />1 <br />1 <br />1.1 <br />L 1A <br />_ <br />FM-12X18 1.1 J <br />— — — — — <br />FM-iTX12 <br />FMC-12X18 <br />— <br />FM-12X18 <br />— — — — — — <br />FMC-12XIS <br />— — <br />4 <br />4 <br />1.1 <br />1.1 <br />10'-2" <br />21'-4" <br />14'-0" 4'-4" <br />39'-8" <br />FOUNDATION PLAN <br />SCALE: 114" = V-0" <br />3 <br />1.1 <br />FOUNDATION NOTES <br />1. SEE SLAB SCHEDULE FOR SLAB REQUIREMENTS. SEE GENERAL NOTES FOR <br />COMPACTING REQUIREMENTS. <br />2. TOP OF FINISHED SLAB SHALL BE +40". <br />3. COLUMN AND FOOTING CENTERLINES, SHALL COINCIDE UNLESS DIMENSIONED <br />OTHERWISE. <br />4. REFERENCE ELEVATION +-0'-W, SEE SURVEY PLOT FOR NGVD. <br />5. PROVIDE A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN <br />TERMITES. TREATMENT SHOULD BE IN ACCORDANCE WITH THE RULES AND LAMS AS <br />ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER <br />SERVICES. <br />S. <br />PROVIDE ISOLATION JOINTS BETWEEN INTERIOR AND EXTERIOR SLABS ON GRADE: <br />PROVIDE 1/2" FELT PAPER AT THE JOINT. <br />7. COORDINATE SLAB ELEVATIONS, STEPS, AND SLOPES WITH ARCHITECTURAL <br />DRAWINGS. <br />8. SEE ARCHITECTURAL DRAWINGS FOR THE ORIENTATION OF THE BUILDING. <br />9. WINDOWS, DOORS AND ROUGH OPENINGS ARE TO BE COORDINATED WITH THE <br />WINDOW/DOOR TYPES AND LOCATIONS NOTED ON THE ARCHITECTURAL DRAWINGS <br />AND WITH THE MANUFACTURES SPECIFICATIONS. <br />10. SEE ARCHITECTURAL DRAWINGS FOR WALKWAY SLAB LAYOUT. <br />11.0INDICATED #5 BAR, OINDICATES 06 BAR,WNDICATES #7 BAR VERTICAL <br />REINFORCING BAR IN CELLS FILLED WITH GROUT. ENDS OF REINF. BARS SHALL BE <br />HOOKED INTO FOUNDATION BOND BEAM OR TIE BEAMS WITH AN ACI STANDARD 90" <br />HOOK. BARS SHALL BE PLACED AS SHOWN IN HE PLANS. <br />12. SPLICES IN REINFORCING BARS SHALL NOT BE LESS THEN 48 BAR DIAMETERS (#5 = <br />30", #6 -36'), AND REINFORCING SHALL BE CONTINUOUS. <br />13. RATIONAL ANALYSIS WAS PERFORMED TO DETERMINE SIZE AND STEEL <br />REINFORCING FOR ALL FOUNDATIONS. DESIGNED WAS BASED ON ALL ALLOWABLE <br />SOIL BEARING CAPACITY OF 2,000 PSF. TRANSFER REINFORCING (TOP STEEL) HAS <br />BEEN DELETED UNLESS NOTED OTHERWISE, <br />14. VERTICAL REINFORCING IN CMU SHALL BE #5'S AS SHOWN ON THIS PLAN, UNLESS <br />OTHERWISE NOTED IN THE PLAN. ONE REINFORCING BAR SHALL BE: <br />A) IN ALL WALL INTERSECTIONS B) CHANGES IN ELEVATION <br />C) EACH SIDE OF ALL OPENINGS D) ALL CORNERS <br />15. STRUCTURAL DESIGN IS IN ACCORDANCE WITH A.C.I. 530.13/ASCE 5-13, BUILDING <br />CODE REQUIREMENTS FOR MASONRY STRUCTURES AND THE COMMENTARY. <br />CONSTRUCTION SHALL BE IN ACCORDANCE WITH A.C.I. 530-13/ASCE 513, USING: Fm = <br />1,500 PSI, TYPE "M" OR"S" MORTAR, ASTM C476 GROUT (3000 PSI), UNITS LAID IN <br />RUNNING BOND. <br />18. WIRE WELDED MESH LOCATED IN THE MIDDLE TO UPPER i OF SLAB SUPPORTED <br />3'-0" O/C MAX. SEE PLAN FOR WWM SIZE. <br />INSPECTOR NOTE: <br />1. STRUCTURE WAS DESIGNED BASED ON THE 2017 FLORIDA RESIDENTIAL BUILDING <br />CODE, RESIDENTIAL, 61h EDITION <br />SLAB SCHEDULE <br />SLAB <br />THICKNESS <br />REINF. <br />REMARKS <br />bk6 W1..1.4 OVER <br />GENERAL <br />3 1Pl' <br />6 MIL VAPOR <br />COMPACTED FILL <br />BARRIER <br />FOOTING SCHEDULE <br />PROVIDE CORNER BARS SAME SIZE QUANTITY AS BARS IN FOUNDATION WITH 3X LEG EACH WAY. <br />MARK <br />WIDTH <br />LENGTH <br />THICKNESS <br />BOTTOM REINF. <br />TOP REINF. <br />T.O.F. <br />SHORT <br />LONG <br />TEA <br />8" <br />SEE PLAN <br />IT <br />- <br />FM-12x12 <br />12, <br />CONTINUOUS <br />1T <br />- <br />(2)#Fs <br />+d'-X <br />FMA208 <br />1T <br />CONTINUOUS <br />16' <br />- <br />(2)#69 <br />FM-16x18 <br />16, <br />CONTINUOUS <br />IV, <br />FMC-12x18 <br />IT <br />CONTINUOUS <br />IV, <br />- <br />( s <br />#5 IN CURB <br />VARIES <br />F-24x24 <br />24" <br />24" <br />1 <br />a <br />e <br />(_)0,1-4" <br />1441 N. RONALD REAGAN BLVD <br />LONGWOOD, FL 32750 <br />PH: 407-774.607E <br />FAX 407-774-4078 <br />wwwAbdesigngroup.com <br />L AA #:.0003325 <br />i <br />q <br />Y <br />0 <br />a <br />_3 <br />44 <br />O <br />Z <br />