Laserfiche WebLink
IIZI1diII►Eel MOW <br />1. U.N.O. ALL STRAPS FOR ROOF TRUSSES TO BE <br />CONCRETE TO WOOD ROOF: USP HTA16 W (9)10d x 1 12" HDG NAILS. <br />SMALL JACKS < 9' MAY BE NAILED W/ (10)d x 1 12" HDG NAILS, CONCRETE TO <br />WOOD FLOOR: <br />USP LPTA W/ (10) 10d x 1 12" HDG NAILS, WOOD TO WOOD: <br />USP RT16A OR LUGT2 W/ 10d x 1 1/2" HDG NAILS, FILL ALL HOLES. <br />2. ALL PLYWOOD FOR WALL AND ROOF SHEATHING IS TO BE PER FASTENER <br />SCHEDULE. <br />3. ALL PLYWOOD FOR FLOOR SHEATHING SHALL BE PER FASTER SCHEDULE <br />MEETING THE REQUIREMENTS OF AFG-01 AND APPLIED IN ACCORDANCE WITH <br />MANUFACTURER'S SPECIFICATIONS. <br />4. ALL NAILS FOR TRUSS TO BEAM AND TRUSS TO TRUSS METAL CONNECTORS <br />ARE TO BE GALVANIZED. <br />5. LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON UNTEL <br />MANUFACTURER SHOWN IN STRUCTURAL PLANS. <br />6. BOTTOM OF LINTELS ARE TO BE PLACED AT TOP OF WINDOW, DOOR AND <br />CLEAR SPAN OPENINGS. <br />7. LINTELS SHALL HAVE 4" NOMINAL BEARING (4-). <br />8. THE TRUSS FRAMING SHOWN IS SCHEMATIC IN NATURE. HOWEVER THE <br />SUPPORTING STRUCTURE HAS BEEN DESIGNED UNDER THE ASSUMPTION THE <br />FRAMING SCHEME SHOWN WALL CLOSELY PARALLEL FINAL TRUSS DESIGNERS <br />LAYOUT. SUBMIT FINAL TRUSS DRAWINGS FOR THE ENGINEER'S REVIEWAND <br />APPROVAL. <br />9. PLACE 2X4 PT TO ALIGN WITH TOP AND BOTTOM CHORDS OF ROOF TRUSSES <br />SECURE 2x MEMBERS TO WALL WITH HILTI X-ZF, POWDER ACCTUATED <br />FASTENER, ZF 72 P8S36, .177" " x 2 7/8" LONG, WITH WASHER Q 16" O.C. <br />10. TRUSS REACTIONS AND UPLIFTS SHOWN) ARE THE SAME ON EACH END <br />UNLESS OTHERWISE SHOWN DIFFERENT. <br />11. WOOD BEARING WALLS AND HEADERS HAVE BEEN DESIGNED BASED ON <br />RATIONAL ANALYSIS. <br />12. ALL ELEVATIONS ARE REFERENCED FROM 0'-0", FINISH FLOOR. UNLESS <br />NOTED OTHERWISE. <br />TRUSS MANUFACTURER / ENGINEER NOTES: <br />1. ROOF GIRDERS W/ UPLIFT IN EXCESS OF 2,500 LES SHALL BE <br />FABRICATED W/ A 2x6 BTM. CHORD (MIN.) <br />2. COORDINATE ANY TRAY/COFFERED CEILINGS, AND ATTIC ACCESS <br />WITH THE ARCHITECTURAL PLANS TRAYS AND COFFERS ARE NOT <br />SHOWN ON THIS PLAN IN ORDER TO AVOID CONFUSION AND MISTAKES. <br />3. TRUSS COMPANY / ENGINEER IS RESPONSIBLE FOR ALL TRUSS TO <br />TRUSS CONNECTIONS. <br />4. AVOID PLACING A TRUSS PERPENDICULAR TO A STEEL COLUMN. <br />MAINTAIN AT LEAST 8" FROM THE CENTER OF THE COLUMN. <br />1-PLY <br />G: 496 LBS <br />U:-145LBS <br />2X4 BLOCKING BETWEEN TRUSSES 24" O.C. <br />TOE NAILED TO ADJACENT TRUSSES W/ (2) 16d <br />COMMON NAILS & SECURE TO RM_ W/ LISP <br />FRAMING PLAN <br />SCALE: 1/4" = 1'-0" <br />1-PLY <br />U:-1003LBS <br />O: 2294 LEIS <br />1-PLY <br />U -40 LBS <br />G:135EI LEIS <br />1-PLY <br />U: 462 LEIS <br />G:ion LBS <br />1-PLY <br />U:-1030ILBS <br />Q 2DO LBS <br />1-PLY <br />U: -W LEIS <br />Q 1071 LEIS <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-7744078 <br />FAX: 407-774-4078 <br />W ww.abdeskgngroupxom <br />AA #: 0003325 J <br />[g- <br />0 <br />h <br />O <br />F <br />i <br />1 <br />sulwiv. ae LOT <br />SILVERADO <br />LOT #14 <br />BLK- #11 <br />Pitoi=T# <br />04128.002-14111 <br />MODEL: <br />4EBB <br />"1828-CALF" <br />GARAGE afrnr0: <br />RIGHT <br />PACE: <br />FRAMING <br />PLAN <br />150 MPH EXP. B <br />ROL4 D A. ABOUCNACRA <br />AR NO 937= <br />DA 10/23/18 <br />scALE: 1/4"=1'—O" <br />aHE= <br />S3 <br />