Laserfiche WebLink
FLOOR DECK <br />2x8 PT TERMINATION <br />2x4 STRONGBACK SECURED TO BLOCKING SECURED TOO W WALL <br />EACH TRUSS W/ (3)18d COMMON W/ (6) 3116" ° x 4 TAPCONS <br />NAILS PROVIDE 2-TRUSS LAP <br />SPLICE LOCATED EITHER TOP OR <br />BOTTOM OF FLOOR TRUSS, <br />TYPICALLY 10'-0" BUT REFER TO <br />TRUSS ENGINEERING <br />2x4 STRONGBACK, <br />FLOOR BRACING <br />SCALE: 3/4"=1'-0' <br />DBL PT 2x8 BLK'NG BETWEEN <br />TRUSSES W/ 10d 0 3' O.C. 1ST PLY <br />INTO LEDGER AND 10d 0 r O.C. #8 WOOD SCREWS <br />STAGGERED UPPER PLY INTO x 2" LONG C 3" O.C.; Nl <br />BELOW STAGGERED OFF <br />CENTERLINE OFF 2.8; <br />314" AS SHOWN <br />DBL 2X8 LEDGER I IT <br />e" CMU WALL TO CMU W/ 112" EXP. BOLT NI <br />REINF PER PLAN AT 18" O.C. AND 8" FROM <br />PER ELEVATION <br />END W/ MIN 5-1/P EMBED. <br />FLOOR DEC I'I �/4" <br />IRIPA�T7M <br />0 <br />r NAILING <br />R ELEVATION <br />=l <br />2x4 P.T. CEILING <br />24" MAX PRE-ENGINEERED WOOD <br />FLOOR TRUSSES (SEE <br />NAILER WI <br />FRAMING PLAN) <br />MASONRY NAILS <br />2' �,G.D. <br />'. REPAIR DETAIL IF <br />X2 FIRE -STOP <br />LEDGER INSTALLED TOO LOW <br />AT TRUSSES PARALLEL <br />TO EXTERIOR WALL <br />5 <br />SCALE: 3/4"=l'-a' <br />USP LFTA6 W/(18)Sd <br />COMMON NAILS, EACH <br />END EVERY STUD OR ON <br />EACH END OF "BUNDLE" <br />OF STUDS <br />PLYWOOD FLOOR <br />SHEATHING <br />USP LFTABW <br />(1618d COMM NAII S <br />EACH END <br />FL#17244 <br />FLOOR TRUSS OR J yVPLATESTRAPS W_ 10dx1 <br />GIRDER TRUSS 1/2" HDG NAILS FL#17235 <br />WALL / FLOOR FRAMING, <br />2 TRUSS PARALLEL TO WALL <br />SCALE: 3/4"=1'-a' <br />PRE-ENG GABLE TRUSS — <br />2x4 BLOCKING BETWEEN TRUSSES <br />AT FIRST TWO BAYS V-U' O.C. (AT <br />SHEATHING SEAMS) (BLOCKING <br />NOT SHOWN FOR CLARITY) <br />SECURE 2x8 PT. PLATE TO BLK <br />W/ 1/2" DIA. ANCHOR SOLT W/ 2' <br />WASHER SET IN HIGH <br />STRENGTH EPDXY B' MIN. <br />EMBED. AT 3T' OC MAX <br />SECURE GABLE TO 2.8 P.T. <br />PLATE W/ 12d's 8' O.C. MAX <br />1/4" <br />DBL PT 2x8 BLK'NG BETWEEN <br />TRUSSES W/ 10d ® 3'O.C. 1ST PLY <br />INTO LEDGER AND 10d (M 3" O.C. <br />#8 WOOD SCREWS x 2" <br />STAGGERED UPPER PLY INTO 2x8 <br />N� <br />LONG Q 3" O.C.; <br />BELOW <br />#8 WOOD SCREWS <br />STAGGERED <br />NI <br />x 2" LONG 0 3" O.C.; <br />AS SHOWN <br />STAGGEREOOFF <br />DBL 2X8 LEDGER <br />CENTERLINE OFF 24; <br />TO CMU W/ 1/2" EXP. BOLT <br />e" CMU WALL <br />3/4' AS SHOWN <br />8" CMU WALL <br />AT 18" O.C. AND 8" FROM <br />N� <br />REINF PER PLAN <br />REINF PER PLAN <br />END W/ MIN 5-12" EMBED. <br />LISP A3 EA <br />FLOOR DECK <br />PER E ATI <br />TRUSS <br />PER <br />NAYJJG PATTEdW <br />k/4 <br />.r NNLNO <br />PATTERN <br />0 ffi� <br />S icS= <br />it ff¢¢jji <br />P ELEVATION <br />L V 1 <br />m=L <br />24" M PRE-ENGINEERED WOOD <br />PRE-ENGINEERED WOOD <br />2x4 P.T. CEILING <br />FLOOR TRUSSES (SEE <br />1X2 FIRE -STOP <br />FLOOR TRUSSES (SEE <br />NAILER W/ <br />FRAMING PLAN) <br />DBL 2X LEDGER FRAMING PLAN) <br />MASONRY NAILS <br />SEE SCHEDULE <br />®120.C. <br />SECTION DETAIL <br />X2FIRESTOP <br />SECTION DETAIL <br />AT TRUSSES BEARING <br />AT TRUSSES PARALLEL <br />ON EXTERIOR WALL <br />TO EXTERIOR WALL <br />3 <br />4 <br />scALE: 3,a"=r-0" <br />scnLE: 3l4^=r-a' <br />TRUSS (TYP) 0 24" O.C. <br />MAX <br />FOR STRAPPING <br />VERIFY <br />W/TRUSS PLAN <br />CONC. POURED <br />LINTEL COURSE <br />— CONT. 2x4 SECURED W/ (2) l0d9 0 EACH <br />TRUSS TO BE INSTALLED 0 10!-a' O.C. MAX <br />GABLE END BRACING W/ PRE-ENG <br />GABLE TRUSS @ CMU WALL <br />8 SCALE: 3/4"=17 <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL32750 <br />PH: 407-774-6078 <br />FAX: 407-7744078 <br />wwwsbdsslgngroup.dom <br />AA #: 0003325 <br />151 <br />nx sDzv ae LOT: <br />SILVERADO <br />LOT #11 <br />BLK" #12 <br />Plo""Tip <br />28.002-11121 <br />moDzu <br />4EHB <br />"2605- HAYDEN" <br />OAV.AGZ NVnNO- <br />LEFT <br />AAOI: <br />DETAILS <br />150 MPH EXP. B <br />RObW A ABOUCHACRA <br />L AR NO 03723 J <br />DATO <br />il/1S/18 <br />NCAMM 1/4"=V-0" <br />NIEM= <br />S3.1B <br />