My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6895 Wagon Trail St
Zephyrhills
>
Building Department
>
Building Plans
>
6895 Wagon Trail St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 9:39:55 AM
Creation date
2/24/2025 9:50:00 AM
Metadata
Fields
Template:
Building Plans
Street #
6895
Location
Wagon Trail St
Contractor
D R Horton
Building Plans - Permit #
20788
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SACKER ROD <br />BACKER ROD <br />WARS LAYER -1, <br />ATIIrrn 111"r <br />INSTALL 6' SELF -ADHERING <br />MEMBRANE PLASHNG OVER <br />TOP, SIDE(S) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SEQUENCE OF FLASHING TO BE, <br />1. BOTTOM, 2. SIDES. 3. TOP <br />VENT CAP IS TO BE SET IN DED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT IS TO BE <br />TOOLED SO AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />JOINTS AND INTERSECTIONS <br />APPLY SEALANT AT PERIMETER OF <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDES, W CAULKING • JOINT <br />ALL AROUND <br />PER SECTION R703.7 <br />EAwlor W*v =W Dlaet ft <br />Exterior use of portiand cement plaster <br />shall comply with the application <br />requirements of ASTM C 926-12A. <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1063-12A. <br />HOODED VENT <br />\\— <br />i' THICK, 9 COAT CEMENT <br />I, <br />PLASTER <br />METAL LATH <br />WRB LAYER 4, FORTIFISER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER <br />VENT ( FRAME) <br />LEGEND <br />DRAINAGE PLANE (UJRB <br />LAYER 01, STUCCO LURAP) <br />WRB LAYER 02 (FORTIFIBER - - - - - <br />BUILDING PAPER) <br />METAL LATH x-x-x-x <br />STUCCO <br />SELF-ADHESIVE FLASHING - - - - - <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R103.1.1 / ASTM C-841-09, MIN. 215 LBS. <br />PER 50. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />STUCCO <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />SELF <br />WOOD SHEATHING <br />FLASHING <br />LAYER -1, <br />UNIT <br />STUCCO WRAP <br />LAYER 4, FORrIFISER <br />PREMANUF. DRYER <br />BUILDING PAPER <br />VENT CAP (SET IN <br />METAL LATH <br />CONT. SEALANT) <br />uboD 1/8, TEXTURED <br />-FINISH! <br />CO OTRJCT104 '. <br />• WOODEN <br />FASTTO WOOD STRUCTURAL <br />SEALANT • <br />MEMBER • 1' OZ. MAX <br />TOP 4 SIDES <br />a u , . __ _ ...... <br />6B DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' <br />PIPE THROWN <br />WALL <br />1 <br />6' SELF ADHESIVE — <br />FLASHING (INSTALL <br />PER MARA SPECS.) <br />BUILDING PAPER — <br />INDER 'QUICK FLASH' <br />A VENT PENETRATION <br />SGALE= N.T.S. <br />ELEC. METEF <br />VERIFY LO <br />NRGfi IV f�G1�G1YG <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />I <br />I <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />I <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />('GREAT STUFF' OR SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />PROVIDE STUCCO SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED WOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LAYER 01, <br />STUCCO WRAP <br />WOOD SHEATHIP <br />APPROVED <br />HOUSEWRAP <br />BELOW <br />CUT SUCH TWA' <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY TO FAU <br />EDGE <br />APPLY E-Z <br />OVER 60 MI <br />GRADE '0' <br />FELT-PROVI'. <br />SEALANT AT <br />JOINTS AND <br />INTERSECTIC <br />R11� <br />W WIDE STRIP SELF <br />ADHESIVE FLASHING. CLEAN <br />MASONRY BEFORE APPLYING <br />V RNIGH • MAeoNRT <br />'7B HORIZONTAL WEEP SCREED <br />FRAME TO BLOCK) <br />8' <br />WRB LAYER @I, <br />STUCCO WRAP <br />CUT 'X' INTO <br />SELF -ADHERING <br />i k <br />MEMBRANE FLASHING <br />q. <br />APPLY SELF -ADHERING <br />MEMBRANE FLASHING <br />OVER BOX AND OVER <br />APPROVED WRB LAYER <br />"I <br />STEP #1 <br />STEP 02 <br />LAYER 01, <br />WRI777f_� <br />STUCCO <br />STUCCO WRAP <br />APPLY 60 MIN - <br />GRADE 'D' FELT <br />OVER <br />SELF -ADHERING <br />FLASHING OVER <br />APROVED <br />HOUSEWRAP <br />STEP *3 <br />ME <br />MBRANE! R ASHING <br />MM LAYER 12, FOWIF15ER <br />BUILDING PAPER <br />STEP #4 <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ G.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />METAL LATH <br />STEP *5 STEP #& <br />(:�) <br />ELECTRICAL RECEPTACLE <br />1441 N. RONALD RFAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-7746078 <br />FAX 407-774-4078 <br />www.abdosigrkgroup.com <br />AA e: 0003325 <br />911111F; <br />SiJ19DIV. Ac LOT: <br />SILVERA )0 <br />LOT #13 <br />BLK #12 <br />PROJECT# <br />04128.002-13121 <br />I[ODELc <br />4EBB <br />"1828-CALI" <br />GARAGZ OWING: <br />LEFT <br />PAGZ: <br />WALL <br />ASSEMBLY <br />DETAILS <br />150 MPH EXP. B <br />D TZ 11/15/18 <br />BCP.XX: 1/4"=1'-0" <br />811=T <br />WA2 <br />