GENERAL REQUIREMENTS: <br />• HARDIESOFFITO PANELS MAY BE INSTALLED AS A SOFFIT OR CEILING OVER EITHER WOOD OR STEEL 20 GAUGE (33 MILS) MINIMUM TO 16 GAUGE (54 MILS) FRAMING COMPLYING WITH THE LOCAL <br />BUILDING CODE. SEE GENERAL FASTENING REQUIREMENTS. INSTALL SOFFITS TO NOMINAL 2X4 FRAMING MEMBERS SPACED A MAXIMUM OF 24 INCHES ON CENTER (FIG.1), WITH THE LONG DIMENSION <br />PERPENDICULAR TO THE RAFTER OR JOIST FRAMING. <br />• ALL EDGES MUST BE SUPPORTED BY FRAMING. (FIGS. 3 & 4) <br />• INSTALL WATER BARRIERS AND AIR BARRIERS AS REQUIRED BY LOCAL BUILDING CODES. JAMES HARDIE WILL ASSUME NO RESPONSIBILITY FOR MOISTURE INFILTRATION. <br />• ENSURE GUTTERS HAVE END CAPS. MAINTAIN A MINIMUM 1" GAP BETWEEN END CAPS AND SIDING & TRIM. <br />. INSTALL KICKOUT FLASHING AT ROOF -WALL JUNCTIONS. <br />• JAMES HARDIE BUILDING PRODUCTS PROVIDES INSTALLATION /WIND LOAD INFORMATION FOR BUILDINGS WITH A <br />MAXIMUM MEAN ROOF HEIGHT OF 85 FEET. FOR INFORMATION ON INSTALLATIONS ABOVE 60 FEET, PLEASE CONTACT <br />JH TECHNICAL SUPPORT. FIGURE 1 <br />INSTALLATION: <br />• HARDIESOFFIT PANELS MUST BE FASTENED TO A SOLID, NAILABLE SUBSTRATE <br />SUCH AS A WOOD 2X SUBFASCIA. <br />• ADDITIONAL FRAMING MAY BE NEEDED TO ENSURE PROPER FASTENING. <br />• SOFFITS CAN BE INSTALLED AS SHOWN IN FIGURE 1. POSITION THE VENT HOLES FIGURE 3 <br />TOWARD THE OUTSIDE OF THE EAVE FOR OPTIMAL AIRFLOW. r LESS THAN OR EQUAL TO <br />• 12" TO 24" WIDE VENTED HARDIESOFFIT PANELS, PROVIDE 5.0 SQUARE �12" WIDE SOFFIT <br />INCHES OF NET FREE VENTILATION PER LINEAL FOOT. �\ <br />• ALTERNATIVELY VENTS CAN BE INSTALLED INTO NON -VENTED SOFFIT. <br />• IF NECESSARY, AN INSECT SCREEN CAN BE INSTALLED USING CONSTRUCTION <br />ADHESIVE. NOTE: NET FREE VENTILATION WILL BE REDUCED. <br />FASTENER POSITIONING: <br />I ( " <br />• POSITION FASTENERS 3/8" FROM PANEL EDGES AND NO CLOSER THAN 2" VENTING TO 1FROM ENDOUTSIDE OF III <br />OF SOFFIT <br />AWAY FROM CORNERS WHEN USING SOFFIT GREATER THAN 12" WIDE (FIG. 4) ESHIMAND NO CLOSER THAN 1" AWAY FROM CORNERS WHEN USING SOFFIT THAT IS FASCIA 3/8" FROM ENDAVELESS THAN OR EQUAL TO 12" WIDE (FIG. 3). HARDIESOFFITO OF SOFFIT <br />(WOOD) VENTED PANEL <br />JOINTING METHODS: SUBFASCIA <br />SIDING <br />INSTALL PANELS IN MODERATE CONTACT AT ENDS, PROVIDE PVC OR METAL <br />JOINTERS, BATTENS OR LEAVE APPROPRIATE GAP AND CAULK (FIG 2). <br />FASTENER REQUIREMENTS: <br />• FOR WOOD FRAME CONSTRUCTION A MINIMUM 4D COMMON NAILS SPACED 8" O.C. AT <br />PANEL EDGES AND INTERMEDIATE FRAMING MEMBERS SPACED UP TO 24" ON CENTER ARE <br />SUITABLE IN MOST LOCATIONS*. <br />• FOR CONVENTIONAL 20GA - 16GA STEEL FRAME CONSTRUCTION A MINIMUM NO. 8-18 X <br />0.323" HD X 1" LONG RIBBED BUGLE SCREWS SPACED 6" O.C. AT PANEL EDGES AND <br />INTERMEDIATE FRAMING MEMBERS SPACED UP TO 24" ON CENTER ARE SUITABLE IN MOST <br />LOCATIONS*. <br />*MINIMUM BASIC WIND SPEED DIFFERS BY LOCALITY. WHERE SPECIFIED LEVELS OF WIND <br />RESISTANCE ARE REQUIRED, REFER TO APPLICABLE BUILDING CODE COMPLIANCE REPORTS. <br />MANUFACTURERS OF ACQ AND CA PRESERVATIVE -TREATED WOOD RECOMMEND SPACER <br />MATERIALS OR OTHER PHYSICAL BARRIERS TO PREVENT DIRECT CONTACT OF ACQ OR CA <br />PRESERVATIVE -TREATED WOOD AND ALUMINUM PRODUCTS. FASTENERS USED TO ATTACH <br />HARDIETRIM TABS TO PRESERVATIVE -TREATED WOOD SHALL BE OF HOT DIPPED ZINC -COATED <br />GALVANIZED STEEL OR STAINLESS STEEL AND IN ACCORDANCE TO 2009 IRC R317.3 OR 2009 MODERATE CONTACT <br />IBC 2304.9.5." �— <br />LEAVE APPROFKIAIt <br />GAP AND CAULK <br />FIGURE 2 <br />MEMBER MEMBER <br />U <br />H-JOINTER O <br />N <br />bA I I tN <br />ING <br />IER <br />FIGURE 4 <br />GREATER THAN <br />12" WIDE SOFFIT <br />KEEP FASTENERS <br />2" AWAY FROM CORNERS <br />3/8" IN FROM <br />EDGE OF SOFFIT <br />1441 N. RONALD REAGAN BLVD. <br />LONG W OOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-774-4078 <br />WW Abdmkpgroup.eom <br />L AA #: 0003325 A <br />8 <br />h <br />c <br />a <br />Q <br />a <br />sUeaiv & LOOT <br />ABBOTT PARK <br />LOT #15 <br />BLK #13 <br />PHASE 4B <br />PROJECT# <br />04181.04B-15131 <br />moDmu <br />4EBB <br />"1828-CALI" <br />GARAGE aMitdc: <br />LEFT <br />PACE: <br />SOFFIT <br />DETAILS <br />160 MPH EXP. C <br />k <br />