HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SMALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAD 4 MASTIC. AND <br />INSTALLED AS PER FBC 1TH EDITION (2020) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FDC 1TN EDITION (2020) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 1TH EDITION <br />(2020) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 1TH EDITION (2020) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL. AIR EXHAUSTED. <br />S. ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/Sh10KE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACOE86 DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC 1TH <br />EDITION (2020) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11. DRYER BOOSTER TO BE A FANTEC4 DBF 5006TER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />SCORIATED NICKEL FIN. FLOOR <br />BRONZE FL. PL. OR WALL <br />BRASS PLUG <br />-�—FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />WADE 8240-K JOSAM 56000 <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.V,C OPTI/SPEC <br />OFLOOR SLAB CLEAN -OUT (T <br />COUNTERSUNK <br />G.O. PLUG <br />FIN. GRADE <br />OR PAVING <br />SEE SPEC. <br />I'-8'XS' CONC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />g)EXT. GROUND CLEAN -OUT (TYPN ) <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TRUNK <br />l <br />BALANCING DAMPER OR OBD <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 0 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />IM <br />PASS-THRU AIR GRILL <br />ATTIC <br />AIR SUPPLY� <br />AIR <br />EVAP. TRAY <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />SECURE STRAP TO CONC.10 <br />W/ (2)-3A6'X2' TAPCON5 UNIT R SIMPSON WB ROLL STRAP <br />EXTERIOR WALL OR EQUAL <br />AIR RETURN <br />SUCTION AND LIQUID 4' CONCRETE SLAB SECURE STRAP TO UNIT W/ (2) <br />REFRIGERANT LINES °BXI I/4' $WT. MTL. SCREWS <br />CONDENSER UNIT <br />EXTERIOR WALL CONNECTION TO PAD <br />3/4' PVC CONDENSATE DRAIN LINE <br />PVC SLEEVE TO LINES BELOW SLAB NOTE: MAIN CONO. DRAIN 3/4' DIA. <br />1 OVER HEAD • 12' FROM STRUCTURE <br />p REFRIGERANT LINES TO <br />RETURN CONDENSING UNIT <br />TRAP DRAIN LINE AND TERMINATE <br />L. IN AN APROVED DRAIN, AS PER <br />FBCR 1TH EDITION (2020) <br />MECHANICAL BLDG. CODE <br />SECTION 3011.4 <br />HVAC DRAINS <br />MECHANICAL PLAN <br />SCALE, 1/4 " I'-& <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-7744078 <br />www,abdesigngrou p.com <br />AA N: 0003325 <br />m <br />i <br />N W <br />f <br />0 <br />x <br />A <br />L <br />avaDIV. ae LOT <br />ABBOTT PARK <br />LOT #12 <br />BLK #13 <br />PHASE #4B <br />PROJECT#. <br />04181.04B-12131 <br />MODEL <br />3EAB <br />"1504- ALLEX" <br />GARAGE ISIMMO: <br />RIGHT <br />PACE: <br />MECHANICAL <br />PLAN <br />%160 MPH EXP. C <br />F—PIATZ: UNT 10/26/21 <br />aCALE: 1/4"=l'—O" <br />u*mwr <br />M1 <br />