My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7380 Sail Clover Ln
Zephyrhills
>
Building Department
>
Building Plans
>
7380 Sail Clover Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 2:55:19 AM
Creation date
2/24/2025 9:27:15 AM
Metadata
Fields
Template:
Building Plans
Street #
7380
Location
Sail Clover Ln
Contractor
D R Horton
Building Plans - Permit #
3434
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />1. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />t'M. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED M NON -CONDITIONED ALAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS PAS 4 MASTIC. AND <br />INSTALLED AS PER FBC ITH EDITION (2020) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 161 CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC ITH EDITION (2020) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC -ITH EDITION <br />(2020) MECHANICAL CODE 603.1 <br />I. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED M ACCORDANCE WITH FBC ITH EDITION (2020) MECHANICAL CODE SECTION <br />403. <br />8. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />% ALL FIRE RATED CEILINGS AND WALLS &HALL HAVE AN APPROVED FIRE OR FIRE/BMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOOR$ TO <br />RESET DAMPER ALL DAMPER& SHALL BE INSTALLED TO MFG. RECOMMENDATION& AND FBC ITH <br />EDITION (2020) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />II. DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH COP 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR 1 WAY DIFFUSER <br />SOLID LINE- SUPPLY TRUNK <br />BROKEN LINE- RETURN TRUNK <br />1 <br />BALANCING DAMPER OR OBD <br />O <br />CEILING EXHAUST PAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />19 <br />PASS-THRU AIR GRILL <br />NOTE <br />ALL HVAC TO HAVE PROPER <br />16XII <br />PANS W/ DRAMS <br />ATTIC <br />— <br />— <br />CEILING <br />O <br />O <br />EXTERIOR WALL <br />SECURE STRAP TO CONC. <br />CONDENSER <br />R <br />I <br />— — <br />AIR RETURN <br />W/ (2)•3/IVX2' TAPCON$ <br />81MP80J WB ROLL STRAP <br />PLENUM <br />1 <br />OR EQUAL <br />KITCHEN I <br />T <br />SUCTION AND LIQUID <br />I <br />&X4 <br />AIR SUPPLY <br />1 <br />LIDS <br />1 <br />SECURE STRAP TO UNIT W/ (2) <br />4' CONCRETE SLAB '8XI V4' SHT, MTL. SCREWS <br />r <br />AIR HANDLER <br />vREFRIGERANT <br />EXTERIOR WALL <br />QOCrM <br />d <br />CONDENSER UNIT <br />-- <br />o 0 <br />-- <br />-I <br />3/4' PVC CONDENSATE DRAM LINE <br />EVAP. TRAY <br />y <br />PVC. SLEEVE TO LIKES BELOW SLAB <br />CONNECTION TO PAD <br />I I I I I <br />? <br />REFRIGERANT LINES TO <br />NOTE: HAM COND. DRAM 3/4' DIA. <br />I I I <br />VENT <br />PLATFORM <br />RETURN <br />CONDENSING WIT <br />OVER HEAD 12' FROM STRUCTURE <br />FOYER <br />I <br />UUAI.L <br />TRAP DRAM LINE AND TERMINATE <br />IN AN APROVED DRAM, AS PER <br />FBGR'ITH EDITION (2020) <br />MECHANICAL BLDG. CODE <br />E-H <br />SECTION W-12.4 <br />HVAC <br />DRAINS <br />GARAGE <br />BCORIATED NICKEL <br />BRONZE FL. PL. <br />FIN. FLOOR <br />OR WALL <br />C Co...,..,.— <br />I <br />I <br />-------- <br />— <br />r-------- <br />BRASS PLUG <br />FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />WADE 8240-K JOSAM 86000 <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.V.0 OPTI/SPEC <br />FLOOR SLAB CLEAN —OUT (TYPN) <br />FIN. GRADE <br />OR PAVING <br />SEE SPEC. <br />I'-&'X&' CON_. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />(g)EXT. GROUND CLEAN —OUT (TYPN ) <br />FIRST FLOOR <br />MECHANICAL PLAN <br />SCALE. V4 . I'-C' <br />1441 N. RONALD REAGAN 8U/D. <br />LONGWOOD,FL 32750 <br />PH: 407-774.6078 <br />FAX: 407.774-4078 <br />www.abdealgngroup.mm <br />AA &: 0003325 <br />g <br />N <br />o <br />.S <br />p <br />r� <br />1 <br />v <br />C <br />S <br />iiLL <br />BUDDlV. At L+OT: <br />ABBOTT PARK <br />LOT #10 BLK #13 <br />PHASE:4B <br />pRoJ=T# <br />04181. 4 -10131 <br />MOD=* <br />3EEB <br />"2260-ELSTON" <br />GAP —ADM 8WVNI is <br />RIGHT <br />PAGE: <br />FIRST FLOOR <br />MECHANICAL <br />PLAN <br />160 MPH EXP. C <br />