HVAC NOTES <br />1. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER FBC 1TH EDITION (2020) MECHANICAL SLOG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 1TH EDITION (2020) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBI 1TH EDITION <br />(2020) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 1TH EDITION (2020) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9, ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER. ALL DAMPERS SHALL BE INSTALLED TO M)FG. RECOMMENDATIONS AND FBC 'ITH <br />EDITION (2020) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING. DAMPERS. <br />IL. DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />_ <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TR IJK <br />1 <br />BALANCING DAMPER OR OBD <br />0 <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />I9 <br />PASS-THRU AIR GRILL <br />NOTE: <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />ATTIC <br />CEILING <br />O <br />O <br />EXTERIOR WALL <br />PLENUM;tR <br />ETURN <br />ON AND LIQUID <br />AIR SUPPLYREFRIGERANT <br />LINES <br />SECURE STRAP TO C24C. <br />CONDENSER <br />W/ (2)-3/16'X2' TAPCONS <br />UNIT <br />SIMPSON WB ROLL STRAP <br />OR EQUAL <br />AIR HANDLERRIOR <br />WALL <br />VC CONDENSATE DRAIN LINE <br />SECURE STRAP TO UNIT W/ (2) <br />EVAP. TRAYLEEVE <br />TO LINES BELOW SLAB4' <br />CONCRETE SLAB °8XI 1/4' SHT. MTL. SCREWS <br />REFRIGERANT LINES TO <br />CONDENSER UNIT <br />PLATFORMCONDENSING <br />UNIT <br />TRAP DRAIN LINE AND TERMINATE <br />CONNECTION TO PAD <br />IN AN APROVED DRAIN, AS PER <br />FBCR 1T14 EDITION (2020) <br />NOTE: MAIN COND. DRAIN 3/4' DIA <br />MECHANICAL. CODE <br />SECTION 3011.4 <br />OVER HEAD • 12' FROM STRICTURE <br />HVAC <br />DRAINS <br />SCORIATED NICKEL FIN. FLOOR <br />BRONZE FL. PL. N OR WALL <br />BRASS PLUG <br />COUNTERSUNK <br />G.O. PLUG <br />SEE SPEC, <br />1'-8•X8' CONC. <br />I <br />I <br />II�1G <br />xxuuvvn�l <br />I <br />I <br />F 5�/A <br />p�NIN <br />BOOING <br />i <br />BEDROOM <br />ABOVE <br />12X8 ---------------+-------' <br />II <br />1 <br />m <br />L�.. <br />_------ <br />12XI2 <br />II I I <br />53 , <br />PASS II <br />BATH #2 THRU II <br />I <br />I 1� <br />I I <br />° <br />N <br />a& -----I -------------------'� <br />50 x <br />� <br />C <br />i I I <br />I I STAR. I <br />I <br />I <br />I <br />KITCHEN <br />I <br />I <br />I <br /><—^F-====__. r�AN <br />25 — —izxe <br />8' S/A <br />FROM Iu <br />ABOVE 1 <br />lu , <br />FOY R 'IrII FLEX <br />III <br />III <br />rd <br />mr <br />�—FITTING OR EXTENSION TO FIN. GRADE-' <br />SOIL OR WASTE AS OR PAVING <br />PORCH <br />REQUIRED FITTING OR ld <br />WADE 8240-KJOSAM 56000 EXTENSION TO SOIL -------------------- <br />OR WASTE AS <br />INSIDE SERIES NICKEL BRASS TOP REQUIRED _ _ _ _ _ <br />CAULK P.V.0 OPTI/SPEC <br />FLOOR SLAB CLEAN -OUT (TYP.� <br />N <br />NEXT. GROUND CLEAN -OUT (TYPN <br />FIRST FLOOR MECHANICAL PLAN <br />SCALE: 1/4 . P-0' <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774.6078 <br />FAX: 407-774-4078 <br />www.abdesigngroup.com <br />AA #: 0003325 <br />F <br />Q <br />c <br />r <br />Q <br />m <br />A <br />11 <br />l <br />IL <br />BUDDIV. Ac LOT <br />ABBOTT PARK <br />LOT #14 <br />BLK #14 <br />PHASE #4C <br />PROJECTS► <br />04181.04C-14141 <br />"ODErr <br />4EHB <br />"2605-HAYDEN" <br />GARAGE 9WING: <br />LEFT <br />PAGE: <br />FIRST FLOOR <br />MECHANICAL <br />PLAN <br />160 MPH EXP. C <br />