HVAC NOTES <br />1. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER FBC 1TH EDITION (2020) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES WALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SWALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC TTH EDITION (2020) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 1TH EDITION <br />(2020) MECHANICAL CODE 6031 <br />1. BATHROOMS CONTAINING. BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 1TH EDITION (2020) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9. ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIR'_ OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO WCs. RECOMMENDATIONS AND FBC 1T14 <br />EDITION (2020) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11. DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />ATTIC <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE. SUPPLY TRUNK <br />— <br />BROKEN LINE. RETURN TFaW <br />BALANCING DAMPER OR OBD <br />O <br />CEILING EXHAUST PAN <br />CEILING EXHAUST FAN • LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THER"IOSTAT <br />m <br />PASS-THRU AIR GRILL <br />NOTE <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />1010 <br />EXTERIOR WALL <br />PLENlY1 <br />T y <br />AIR RETURN <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />SECURE STRAP TO CONC. CONDENSER <br />W/ (2)-3A6'X2' TAPCCNS UNIT SIMPSON WB ROLL STRAP <br />b <br />OR EQUAL <br />AIR HANDLER <br />EXTERIOR WALL <br />y <br />3/4. PVG CONDENSATE DRAIN LINE <br />SECURE STRAP TO WIT W/ (2) <br />EVAP. TRAY <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />4' CONCRETE SLAB •8XI 1/4' SHT. MTL SCREWS <br />T <br />REFRIGERANT LINES TO <br />CONDENSER UNIT <br />PLATFORM <br />��� <br />`RADENSING UNIT <br />TRAP DRAM LINE AND TERMINATE <br />DRAINLINE <br />CONNECTION TO PAD <br />IN AN APROVEDRAIN, PER <br />FBCR 1TH EDITION (2020) <br />MECHANICAL BLDG. CODE <br />NOTE: MAIN COND. DRAIN 3/4' DIA <br />SECTION 3012.4 <br />OVER HEAD' 12' FROM STRICTURE <br />HVAC <br />DRAINS <br />SCORIATED NICKEL FIN, FLOOR <br />BRONZE FL. PL. � � � WALL <br />COUNTERSUNK <br />C.O. PLUG <br />I,_6. <br />WE SPEC. <br />BRASS PLUG <br />�---FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED—WADE <br />EQUIRED 00 WADE 8240-K JOSAM 560 <br />INSIDE / FSERIES NICKEL BRASS TOP <br />CAULK P.VIC OPTI/SPEC <br />OFLOOR SLAB CLEAN -OUT (T <br />RK GRADE <br />OR PAVING <br />1'-5'XS' CONC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />NEXT. GROUND CLEAN -OUT (TYPN ) <br />r---------- <br />-- <br />1 <br />- <br />-- — <br />— — — — <br />D <br />I <br />I <br />14' S/A <br />FROM <br />KOUM <br />A50VE <br />BEDROOM <br />---- <br />I <br />X3 <br />I I <br />II <br />12XI2 <br />14X6 <br />------ <br />I <br />II <br />j j PASS <br />' <br />THRU BATH #2 <br />11----�X <br />0 <br />I------------------- <br />X ,I <br />KITCHEN <br />I <br />I I STOR, I I I <br />I <br />_ <br />WH <br />o <br />12XS 8X4 <br />i ♦ m. _ <br />\ III <br />III <br />FLEX IIl FOYE <br />III <br />III <br />I <br />PORCH <br />I <br />I <br />— — — — — — — — — — — — — — <br />S' S/A <br />FROM <br />ABOVE <br />GARAGE <br />FIRST FLOOR <br />MECHANICAL PLAN <br />SCALE: 1/4 • 1'-0' <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774,6078 <br />FAX 407-774 O78 <br />www.abdesigngroup.com <br />AA #: 0003326 <br />o <br />rn <br />C <br />a <br />a <br />14 <br />c <br />ee <br />a <br />avaDry Sc LOT: <br />ABBOTT PARK <br />LOT #21 <br />BLK #12 <br />PHASE #4C <br />PROJECT# <br />04181.04C-21121 <br />MODELa <br />4EHB <br />"2605- HAYDEN" <br />GARAGE 811MG: <br />RIGHT <br />PAGE: <br />FIRST FLOOR <br />MECHANICAL <br />PLAN <br />160 MPH EXP. C <br />191 <br />A A <br />NO <br />DltmT <br />ATUM 02/08/22 <br />BCALE: 1/4"=1'-0" <br />NNEET <br />M1 <br />