Laserfiche WebLink
GENERAL REQUIREMENTS: <br />• HARDIESOFFIT® PANELS MAY BE INSTALLED AS A SOFFIT OR CEILING OVER EITHER WOOD OR STEEL 20 GAUGE (33 MILS) MINIMUM TO 16 GAUGE (54 MILS) FRAMING COMPLYING WITH THE LOCAL <br />BUILDING CODE. SEE GENERAL FASTENING REQUIREMENTS. INSTALL SOFFITS TO NOMINAL 2X4 FRAMING MEMBERS SPACED A MAXIMUM OF 24 INCHES ON CENTER (FIG. 1), WITH THE LONG DIMENSION <br />PERPENDICULAR TO THE RAFTER OR JOIST FRAMING. <br />• ALL EDGES MUST BE SUPPORTED BY FRAMING. (FIGS. 3 & 4) <br />• INSTALL WATER BARRIERS AND AIR BARRIERS AS REQUIRED BY LOCAL BUILDING CODES. JAMES HARDIE WILL ASSUME NO RESPONSIBILITY FOR MOISTURE INFILTRATION. <br />• ENSURE GUTTERS HAVE END CAPS. MAINTAIN A MINIMUM 1" GAP BETWEEN END CAPS AND SIDING & TRIM. <br />• INSTALL KICKOUT FLASHING AT ROOF -WALL JUNCTIONS. <br />• JAMES HARDIE BUILDING PRODUCTS PROVIDES INSTALLATION NVIND LOAD INFORMATION FOR BUILDINGS WITH A <br />MAXIMUM MEAN ROOF HEIGHT OF 85 FEET. FOR INFORMATION ON INSTALLATIONS ABOVE 60 FEET, PLEASE CONTACT <br />JH TECHNICAL SUPPORT. <br />FIGURE 'I <br />INSTALLATION: <br />• HARDIESOFFIT PANELS MUST BE FASTENED TO A SOLID, NAILABLE SUBSTRATE <br />SUCH AS A WOOD 2X SUBFASCIA. <br />• ADDITIONAL FRAMING MAY BE NEEDED TO ENSURE PROPER FASTENING. <br />• SOFFITS CAN BE INSTALLED AS SHOWN IN FIGURE 1. POSITION THE VENT HOLES <br />TOWARD THE OUTSIDE OF THE EAVE FOR OPTIMAL AIRFLOW. <br />• 12" TO 24" WIDE VENTED HARDIESOFFIT PANELS, PROVIDE 5.0 SQUARE <br />INCHES OF NET FREE VENTILATION PER LINEAL FOOT. <br />• ALTERNATIVELY VENTS CAN BE INSTALLED INTO NON -VENTED SOFFIT. <br />• IF NECESSARY, AN INSECT SCREEN CAN BE INSTALLED USING CONSTRUCTION <br />ADHESIVE. NOTE: NET FREE VENTILATION WILL BE REDUCED. <br />FASTENER POSITIONING: <br />POSITION FASTENERS 3/8" FROM PANEL EDGES AND NO CLOSER THAN 2" <br />AWAY FROM CORNERS WHEN USING SOFFIT GREATER THAN 12" WIDE (FIG. 4) <br />AND NO CLOSER THAN V AWAY FROM CORNERS WHEN USING SOFFIT THAT IS <br />LESS THAN OR EQUAL TO 12" WIDE (FIG. 3). <br />JOINTING METHODS: <br />INSTALL PANELS IN MODERATE CONTACT AT ENDS, PROVIDE PVC OR METAL <br />JOINTERS, BATTENS OR LEAVE APPROPRIATE GAP AND CAULK (FIG 2). <br />FASTENER REQUIREMENTS: <br />• FOR WOOD FRAME CONSTRUCTION A MINIMUM 4D COMMON NAILS SPACED 8" O.C. AT <br />PANEL EDGES AND INTERMEDIATE FRAMING MEMBERS SPACED UP TO 24" ON CENTER ARE <br />SUITABLE IN MOST LOCATIONS*. <br />• FOR CONVENTIONAL 20GA - 16GA STEEL FRAME CONSTRUCTION A MINIMUM NO. 8-18 X <br />0.323" HD X 1" LONG RIBBED BUGLE SCREWS SPACED 6" O.C. AT PANEL EDGES AND <br />INTERMEDIATE FRAMING MEMBERS SPACED UP TO 24" ON CENTER ARE SUITABLE IN MOST <br />LOCATIONS*. <br />*MINIMUM BASIC WIND SPEED DIFFERS BY LOCALITY. WHERE SPECIFIED LEVELS OF WIND <br />RESISTANCE ARE REQUIRED, REFER TO APPLICABLE BUILDING CODE COMPLIANCE REPORTS. <br />MANUFACTURERS OF ACQ AND CA PRESERVATIVE -TREATED WOOD RECOMMEND SPACER <br />MATERIALS OR OTHER PHYSICAL BARRIERS TO PREVENT DIRECT CONTACT OF ACQ OR CA <br />PRESERVATIVE -TREATED WOOD AND ALUMINUM PRODUCTS. FASTENERS USED TO ATTACH <br />HARDIETRIM TABS TO PRESERVATIVE -TREATED WOOD SHALL BE OF HOT DIPPED ZINC -COATED <br />GALVANIZED STEEL OR STAINLESS STEEL AND IN ACCORDANCE TO 2009 IRC R317.3 OR 2009 MODERATE CONTACT <br />IBC 2304.9.5." <br />LtAVt Al VKUVKIAI t <br />GAP AND CAULK <br />121c Mi N <br />FRAMING <br />MEMBER <br />NG <br />ER <br />H-J( <br />BATTEN <br />NG <br />ER <br />ING <br />IER <br />FIGURE 3 <br />LESS THAN OR EQUAL TO <br />12" WIDE SOFFIT <br />1" FROM END <br />OF SOFFIT <br />° <br />3/8" FROM END <br />OF SOFFIT <br />° <br />FIGURE 4 <br />GREATER THAN <br />12" WIDE SOFFIT <br />P FASTENERS <br />WAY FROM CORNERS <br />IN FROM <br />3E OF SOFFIT <br />• <br />• <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407.774.6078 <br />FAX: 407-774-4078 <br />www.abdesigngroup.com <br />AA #: 0003325 <br />r <br />� <br />� <br />8 <br />o <br />$UDDIV. & Lo <br />ABBOTT PARK <br />LOT #12 <br />BLK #14 <br />PHASE #4C <br />P1t0.1$CT# <br />04181.04C-12141 <br />MODZU <br />4EAB <br />"1672-ARIA" <br />OARAOE $IIIIJO: <br />LEFT <br />PAO= <br />SOFFIT <br />DETAILS <br />160 MPH EXP. C <br />ROLAAW A ABoUCWCRA <br />L AR NO 93723 <br />n <br />