0 <br />HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />I"M REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED ALAS 844ALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB t MASTIC. AND <br />INSTALLED AS PER FBC NTH EDITION (2020) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL, BE CONSTRICTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 1TH EDITION (2020) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC ITN EDITION <br />(2020) MECHANICAL CODE 603J <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH MC ITH EDITION (2020) MECHANICAL CODE SECTION <br />403. <br />8, ALL EXHAUSTED BATH ROOMS, SHALL NAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9. ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC 1TH <br />EDITION (2020) MECHANICAL CODE SECTION 601. <br />10, GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11. DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 50 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />m <br />RETURN AIR GILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LIKE- SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TRUNK <br />l <br />BALANCING DAMPER OR OBD <br />0 <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />m <br />PASS-THRJ AIR GRILL <br />NOSE: <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />SECURE STRAP TO CONC. <br />CONDENSER <br />ATTIC <br />W/ (2)-3/I6'X2' TAF'CONS <br />UNIT <br />SIMPSON WB ROLL STRAP <br />OR EQUAL <br />CEILING <br />O <br />O <br />EXTERIOR WALL <br />PLENUM <br />y <br />AIR RETURN <br />SECURE STRAP TO WIT W/ (2) <br />4' CONCRETE SLAB 08X1 1/4' $HT. MTL. SCREWS <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />CONDENSER UNIT <br />AIR HANDLER <br />y <br />CONNECTION TO PAD <br />EXTERIOR WALL <br />y <br />3/4' PVC CONDENSATE DRAIN LINE <br />NOTE: MAIN COND. DRAIN 3/4' DIA. <br />OVER HEAD s n' FROM STRUCTURE <br />EVAP. TRAY:?, <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />p <br />REFRIGERANT LINES TO <br />PLATFORM <br />RETURN <br />CONDENSING WIT <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />FBCR'1TH EDITION (2020) <br />MECHANICAL BLOC, CODE <br />SECTION 30-1.2.4 <br />HVAC <br />DRAINS <br />SCORIATED NICKEL /� FIN. FLOOR COUNTERSUNK <br />BRONZE FL. PL. / OR WALL C.O. PLUG <br />BRASS PLUG <br />--"�FITTMG OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />///--- WADE 8240-K JOSAM 56000 <br />INSIDE / SERIES NICKEL BRASS TOP <br />CAULK / P.V.COPTI/SPEC <br />OFLOOR SLAB CLEAN -OUT (TYP.) <br />N <br />FIN. GRADE <br />OR PAVING <br />9EE sPEc. <br />r;OZR <br />r-e•x8• coNc.FITTING OREXTENSION TO SOIL <br />WASTE AS <br />QUIRED <br />NEXT. GROUND CLEAN -OUT (TYP. <br />N <br />MECHANICAL PLAN <br />SCALE: 1/4 . 1'-0' <br />NOTE: <br />ALL MECHANICAL EQUIPMENT <br />SHALL BE INSTALLED AT OR <br />ABOVE F.P.E. ELEVATION. �l <br />7m <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL32760 <br />PH: 407-774.8078 <br />FAX 407-7744078 <br />www.abdesigngroup.com <br />AA k: 0003325 <br />9 <br />IPI <br />UBDM & LotilABBOTT PARK <br />LOT #17 <br />BLK #12 <br />PHASE 4C <br />OJECT# <br />04181.04C-17121 <br />MODZI1 <br />4EAB <br />"1672-ARIA" <br />GARAGE BWMG: <br />RIGHT <br />1 PAGE: <br />MECHANICAL <br />PLAN <br />160 MPH EXP. C <br />1 <br />A <br />PRINT <br />awTE: 02/07/22 <br />BCAL.E: 1/4"=1'-0" <br />BlIEET <br />M1 <br />