HVAC NOTES <br />1. ALL MECI-IANICAL EQUIPMENT SMALL BE PROVIDED UTW PROPER CLEARANCE, FOR SERVICING, PER <br />MFa REQUIRIIEMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS $14ALL BE C04STRUCTED OF: A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL SE SEALED WITH CLASS PA15 4 MASTIC. AND <br />INSTALLED AS PER F5C 1TI4 EDITION (2020) MECWMICAL ISLDa CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 101 CLASS I AIR DUCT AS PER NPPA 90A 2-3.1 <br />4. FRESH AIR NTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEtLER VENT OUTLET <br />S. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALv. METAL.. <br />OR OTHER MATERIALS AS PER FI5-_ ITW EDITION (2020) MEC44MICAL CODE SECTION 603 <br />IS. ENCLOSED SUPPORt PLATFOIW16 514ALL BE 0ONSTRIACTED IN AC40RDANCE TO FBC ITW EDITION <br />(2020) MECHANICAL CME 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SWOUERS, SPAS AND SIMILAR BATHING FIXTURES SkALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC IT14 EDITION (2020) MECHANICAL C40DE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL 14AVE UNDER -CUT DOORS FOR MAKE -UF` AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />S. ALL FIRE RATED CEILINGS AND WALLS 614ALL WAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WqTI4 ACCE86 DOORS TO <br />RESET DAMPEFt ALL DAMPERS SHALL BE INSTALLED TO MF& REC40MIENDATIONS AND FBC 1TH <br />EDITION (29)20) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DI IRS SMALL BE PROVIDED tLnTW BALANCING DAMPERS. <br />11. DRYER BOOSTER TO BE A FANTEC14 DBF BOOSTER FAN OR EQUAL. <br />PANTEC44 DBF 110 DRYER BOOSTER CAPACITY 60 LMAR FEET WITH MAX. SIX EI_50UZ� <br />LEGEND <br />SUPPLY AIR DIFFUWR <br />RETURN AIR GRILL <br />OIDE-WALL OR I WAY DIFFUSER <br />SOLID LINE- SUPPLY TFakK <br />BROKEN LtNE- RETURN TRI.W <br />BALANCING DAMPER OR OB0 <br />CEILING. EXHAUST PAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />(D <br />THERMOSTAT <br />C&I <br />PASS-THRU AIR GRILL <br />SECOND FLOOR MECHANICAL PLAN <br />eCALE: 1/4 - I'-V <br />FREE DRAW AIR <br />WANDLER CLOSET <br />W/LOUVERED DOOR <br />SUPPLIED By <br />BUILDER <br />1"I N. RONALD REAGAN BLVD <br />LONGWOOD, FL32750 <br />PH: 407-774-6078 <br />FAX: 407-7744078 <br />www.abdesigngroup.com <br />L AA #,. 0003325 A <br />in <br />0 0 <br />mmmumo <br />P'SrJ]3Drv. Z ILOI-14 <br />ABBOTT PARK <br />LOT #24 <br />BLK #12 <br />PROJZCT# <br />04181.000-24121 <br />MODL'U* <br />3EFB <br />"2447—ROBIE" <br />GAP -%GE 8WING: <br />LEFT <br />PAGM- <br />SECOND <br />FLOOR <br />MECHANICAL <br />PLAN <br />Q6Q,MPH �A j <br />A 7 <br />AA <br />NO <br />I--' 06/14/21 <br />DATIC: <br />SCAJAM 1/4" = l'-O' <br />S L"r <br />HE M2 <br />