Laserfiche WebLink
INSTALL 6' SELF -ADHERING <br />MEMBRANEPLASHMG OVER <br />TOP, SIDE(S) D BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />I: •X: VENT CAP IS TO SE SET N BED <br />OF SEALANT AT TOP AND <br />(� SIDES ONLY. SEALANT 16 TO BE <br />TOOLED SO AS TO DEFLECT <br />r WATER AWAY FROM JOINTS. <br />E-Z 89AD ALL AROUND <br />T-APPLY ALANT ALL <br />JOINTS TTS AND INTERSECTIONS <br />APPLY SEALANT AT PERIMETER OF <br />BACKER ROD <br />I- <br />NON-MOVASLE FRAME AND STUCCO <br />ON AL41 CAULKING • JOINT <br />ALL AROUND <br />PER SECTION R703.7 <br />Exterior latldna and plashing <br />BACKER ROD <br />Exterior use of portland cement plaster <br />shall comply with the application <br />.X <br />requirements of ASTM C 926-18b. <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1063-19a, <br />or ASTM 1787. <br />WRS LAYER h, <br />STUCCO WRAP <br />i <br />HOODED VENT <br />THICK, 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />WRS LAYER 4, FORTIFISER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER VENT <br />( FRAME) <br />WOOD SHEAT14M <br />LAYER'1, <br />STUGCA WRAP <br />LAYER 4, FORT]FIBER <br />BUILDING PAPER <br />C�ONDTUCTION <br />--METAL LATH <br />8' cm VINYL CAWr. BEAD <br />W RAISED BAND <br />$' 70 JY rwtn_u�� <br />1,66P ff'OrCIS <br />6' WIDE STRIP SELF <br />ADWE61VE FLASHING, CLEAN <br />MASONRY BEFORE APPLYM <br />Z PLASHING <br />ST" VENEER <br />OVER SCRATCH COAT <br />HORIZONTAL WEEP SCREED <br />W/STONE VENEER <br />(FRAME TO BLOCK <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER 02 (FORTIFIBER — — — — — <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />WOOD OR -I/16" ZIP WALL <br />SHEATHING <br />SELF-ADHESIVE FLASHING — — — — — <br />NOTE. <br />METAL LATH: LATH TO BE PER SECTION <br />R103.1.1 / ASTM C-641-14a, MIN. 2.5 LBS. <br />PER SQ. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP < SIDES <br />FLASHING <br />UNIT <br />PREMANUF. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT <br />TOP t SIDES <br />6B DRYER VENT (BLOCK) <br />BUILDING PAPER -- <br />OVER 'QUICK <br />FLASH' <br />PIPE THROUGH <br />WALL <br />1 <br />6' SELF ADHESIVE — <br />FLASHING (INSTALL <br />PER MANUF. SPECS.) <br />BUILDING PAPER <br />UNDER 'QUICK FLASH' <br />A_ VENT PENETRATION <br />SCALE, N.T.S. <br />ELEC. METEF <br />VERIFY LO <br />iilCCfi I V RCVCIYC <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />I <br />—ELEC. METER FIELD <br />VERIFY LOCATION <br />UOOD CONSTRUCTION <br />WOOD SHEATHING <br />WRB LAYER 01, <br />STUCCO WRAP <br />WRB LAYER 02, FORTIF15ER <br />BUILDING PAPER <br />J' THICK, 3 COAT CEMENT <br />PLASTER <br />Ye' TO Ye' MID -WALL <br />WEEP SCREED <br />�-6' SELF-ADHESIVE <br />FLASHING <br />WOOD FRAMED <br />WALL <br />HORIZONTAL WEEP SCREED <br />( FRAME TO FRAME) <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOGYANOTE-POLYBLEND FOAM <br />-('GREAT STUFF' OR SIMILAR) <br />—'--APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />PROVIDE STUCCO SCRATCH <br />COAT LLASER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />WOOD SHEATHING <br />OURS LAYER h, <br />STUCCO WRAP <br />WRS LAYER -2, FORTIP15ER <br />BUILDING PAPER <br />METAL LATH <br />FINXrURED <br />ISH s Wo= <br />-FASTEN TO WOOD STRUCTURAL <br />MEMOER • 1'Or, MAX <br />t EEP 112111 DWALL <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYIN <br />(�oHORIZONTAL WEEP SCREED <br />FRAME TO BLOCK) <br />1. <br />WRIB 01, <br />CUT OPENING IN <br />STUCCOYER WRAP <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />CUT 'A' INTO <br />WRS LAYER 01, <br />SELF -ADHERING <br />f 1 <br />STUCCO WRAP <br />MEMBRANE FLASHING <br />APPLY SELF -ADHERING <br />WOOD SHEATHING <br />MEMBRANE FLASHING <br />OVER BOX AND OVER <br />APPROVED WRB <br />LATER M <br />STEP *1 <br />STEP 1*2 <br />r v~V BELOW <br />WRS LAYER M, <br />STUCCO IWRAP <br />CUT SUCH THAT <br />9 <br />APPLY 60 MIN <br />SELF -ADHERING <br />NO MEMBRANE <br />GRADE TP FELT <br />MEMBRANE FLASHING <br />ENTERS BOX, <br />OVER <br />APPLY TO FACE <br />SELF -ADHERING <br />EDGE <br />FLASHING OVER <br />APROVED <br />HOUSEWRAP <br />WRB LAYER 02, FORTIFISER <br />BUILDING PAPER <br />STEP #3 <br />STEP *4 <br />APPLY E-Z BEAD <br />OVER 60 MIN <br />GRADE 'D' <br />FELT -PROVIDE <br />SEALANT AT ALL <br />JOINTS AND <br />INTERSECTIONS <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ C.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />'ETAL LATH <br />STEP *5 STEP #& <br />@) ELECTRICAL RECEPTACLE <br />MAY I <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD,FL32750 <br />PH: 407-774-6078 <br />FAX: 407-774-4078 <br />www.abdesigngroup.com <br />` AA #: 0003325 <br />y <br />a <br />� <br />x <br />6 <br />5 <br />to <br />a <br />b <br />