HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SMALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICMG, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED N NON -CONDITIONED AREAS SQL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATNG. ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER FBC 1TH EDITION (2020) MECHANICAL BLDG, CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER MC 1TH EDITION (2020) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 'lTH EDITION <br />(2020) MECHANICAL CODE 603J <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED M ACCORDANCE WITH FBC 1TH EDITION (2020) MECHANICAL CODE SECTION <br />403. <br />8. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />% ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC 1TH <br />EDITION (2020) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />It DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TRUNK <br />1 <br />BALANCING DAMPER OR OBD <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />m <br />PASS-THRU AIR GRILL <br />Nam: <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />SECURE STRAP TO CONC. CONDENSER <br />W/ (2)-3Ab`X2' TAPC0NS WIT <br />SIMPSON WB ROLL STRAP <br />>C- <br />OR EQUAL <br />CEILING <br />EXTERIOR WALL <br />PLENUM <br />T y <br />AIR RETURN <br />SECURE STRAP TO UNIT W/ (2) <br />4' CONCRETE SLAB <br />�8XI 1/4' SHT. MTL. SCREWS <br />SUCTION AND LIQUIDN <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />CONDENSER <br />UNIT <br />AIR HANDLER <br />y <br />CONNECTION <br />TO PAD <br />EXTERIOR WALL <br />y <br />3/4' PVC CONDENSATE DRAM LINE <br />NOTE: MAIN COND. DRAIN 3/4' DIA. <br />OVER HEAD • 12' FROM STRUCTURE <br />EVAP. TRAY <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />T <br />REFRIGERANT LINES TO <br />PLATFORM <br />RETURN <br />CONDENSING UNIT <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />VMECHANICAL <br />F'BCR 1TH EDITION (2020) <br />SLOG. CODE <br />SECTION -4012.4 <br />HVAC <br />DRAINS <br />SCORIATED NICKEL <br />BRONZE FL. PL. <br />FIN. FLOOR <br />OR WALL <br />COUNTERSUNK <br />C.O. PLUG <br />� <br />� <br />--SEE SPEC. <br />FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.Vr_ OPTI/SPEC <br />nFLOOR SLAB CLEAN -OUT (T <br />FIN. GRADE <br />OR PAVING <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />NEXT. GROUND CLEAN -OUT (TYPN <br />■ <br />MECHANICAL PLAN <br />SCALE: 1/4 - I'-0' <br />NOTE: <br />ALL MECHANICAL EQUIF7'1ENT <br />SHALL BE INSTALLED AT OR <br />ABOVE F.P.E. ELEVATION. <br />/I <br />1441 N. RONALD RFAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-7746078 <br />FAX 407-7744078 <br />wwwabdesigngroup.com <br />AA #: 0003325 <br />F <br />b <br />x <br />a <br />2 <br />sysDiv. ae LOT <br />ABBOTT PARK <br />IAT #8 <br />BLK #12 <br />PHASE #4C <br />PROJECT# <br />04181.04C-08121 <br />MODEL <br />4EBB <br />"1828-CALI" <br />GARAGE SWING: <br />LEFT <br />PAGE. <br />MECHANICAL <br />PLAN <br />11-60-MIPIHI EXP C <br />C1 <br />• t x <br />DATE: <br />12/07/21 <br />SCALE: 1/4"=1'-0" <br />SHEET <br />146 M1 <br />