My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7546 Broad Pointe Dr
Zephyrhills
>
Building Department
>
Building Plans
>
7546 Broad Pointe Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 12:09:03 PM
Creation date
2/24/2025 9:51:43 AM
Metadata
Fields
Template:
Building Plans
Street #
7546
Location
Broad Pointe Dr
Contractor
D R Horton
Building Plans - Permit #
2900
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />1. ALL MECHANICAL EQUIPMENT S"LL M PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />I'M REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH CsLASS PAIS 4 MASTIC. AND <br />INSTALLED AS PER FBC 'NTH EDITION (2020) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS 6"LL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NIFPA WA 2-3.1 <br />4. FRESH AIR INTAKES V".L NQT BE LOCATED CLOSER THAN 10 PT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SELLER VENT OUTLET <br />S. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 1TH EDITION (2020) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORM SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 1TH EDITION <br />(2020) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHNG FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH PBC 1TH EDITION (2020) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO I E <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />S. ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND ISE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MF& REC.OMIMENDATION& AND MC 'ITH <br />EDITION (2020) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCNG DAMPERS. <br />II. DRYER BOOSTER TO BE A PANMC 4 DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />NOTE <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />ATTIC <br />IOR WALL <br />ETURN <br />ON AND LIQUID <br />AIR SUPPLY <br />GERANT LINES <br />AIR HANDLER <br />IOR WALL <br />VC CONDENSATE DRAM LINE <br />TMECHANICAL <br />EVAP. TRAYLEEVE <br />TO LINES BELOW SLABIGERANT <br />LINES TO <br />PLATFORM <br />CONDENSING UNIT <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAM, AS PER <br />FBCR 1TH EDITION (2020) <br />CHANICAL BLDG. CODE <br />SECTION 3012A <br />HVAC <br />DRAINS <br />SCORIATED NICKEL <br />BRONZE FL PL. <br />FIN. FLOOR <br />OR WALL <br />BRASS PLUG <br />—"�--FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />WADE 8240-K JOSAM 56000 <br />INSIDE SERIES NICKEL BRA66 TOP <br />CAULK P.V.0 OPTI/SPEC <br />FLOOR SLAB CLEAN -OUT (T <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR 1 WAY DIFFUSER <br />— <br />SOLID LINE. SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TRUNK <br />BALANCING DAMPER OR 010 <br />0 <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />m <br />PASS-THRJ AIR GRILL <br />SECURE STRAP TO CONC. <br />W/ (2)-3/16'X2' TAPCONS GONUNIT SIMPSON WIS ROLL STRAP <br />OR EQUAL <br />4' CONCRETE SLAB SECURE <br />Vd' gHT. j"PITL.. SCUIB f 2) <br />CONDENSER UNIT <br />CONNECTION TO PAD <br />NOTE= MAIN COND. DRAM 3/4' DIA. <br />OVER HEAD • 12' PROM STRUCTURE <br />C.O. PLUG <br />FIN. GRADE <br />OR PAVNG <br />SEE SPEC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE A8 <br />REQUIRED <br />ZEXT. GROUND CLEAN -OUT (TYPN ) <br />FIRST FLOOR <br />MECHANICAL PLAN <br />SCALE, 1/4 • I'-0' <br />1441 N. RONALD REAGAN BLVD.! <br />LONG WOOD, FL 32750 <br />PH: 407.7746078 <br />FAX: 407-7744078 <br />www.abdesigngroup. <br />L AA 0 J <br />�' <br />o <br />
The URL can be used to link to this page
Your browser does not support the video tag.