My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7546 Broad Pointe Dr
Zephyrhills
>
Building Department
>
Building Plans
>
7546 Broad Pointe Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 12:09:03 PM
Creation date
2/24/2025 9:51:43 AM
Metadata
Fields
Template:
Building Plans
Street #
7546
Location
Broad Pointe Dr
Contractor
D R Horton
Building Plans - Permit #
2900
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FOUNDATION NOTES <br />1. SEE SLAB SCHEDULE FOR SLAB REQUIREMENTS. SEE GENERAL NOTES FOR <br />COMPACTING REQUIREMENTS. <br />2. TOP OF FINISHED SLAB SHALL BE +4-0". <br />3. COLUMN AND FOOTING CENTERLINES, SHALL COINCIDE UNLESS DIMENSIONED <br />OTHERWISE. <br />4. REFERENCE ELEVATION +4-0", SEE SURVEY PLOT FOR NAVD. <br />5. PROVIDE A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN <br />TERMITES. TREATMENT SHOULD BE IN ACCORDANCE WITH THE RULES AND LAWS AS <br />ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER <br />SERVICES. <br />6. PROVIDE ISOLATION JOINTS BETWEEN INTERIOR AND EXTERIOR SLABS ON GRADE: <br />PROVIDE 1/2" FELT PAPER AT THE JOINT. <br />7. COORDINATE SLAB ELEVATIONS, STEPS, AND SLOPES WITH ARCHITECTURAL <br />DRAWINGS. <br />8. SEE ARCHITECTURAL DRAWINGS FOR THE ORIENTATION OF THE BUILDING. <br />9. WINDOWS, DOORS AND ROUGH OPENINGS ARE TO BE COORDINATED WITH THE <br />WINDOW/DOOR TYPES AND LOCATIONS NOTED ON THE ARCHITECTURAL DRAWINGS <br />AND WITH THE MANUFACTURES SPECIFICATIONS. <br />10. SEE ARCHITECTURAL DRAWINGS FOR WALKWAY SLAB LAYOUT. <br />1 1.171NDICATES #5 BAR, ®INDICATES #6 BAR, ONDICATES #7 BAR VERTICAL <br />REINFORCING BAR IN CELLS FILLED WITH GROUT, ENDS OF REINF. BARS SHALL BE <br />HOOKED INTO FOUNDATION BOND BEAM OR TIE BEAMS WITH AN ACI STANDARD 90" <br />HOOK. BARS SHALL BE PLACED AS SHOWN IN HE PLANS. <br />12. SPLICES IN REINFORCING BARS SHALL NOT BE LESS THEN 48 BAR DIAMETERS (#5 = <br />30", #6 -36'), AND REINFORCING SHALL BE CONTINUOUS. <br />13. RATIONAL ANALYSIS WAS PERFORMED TO DETERMINE SIZE AND STEEL <br />REINFORCING FOR ALL FOUNDATIONS. DESIGNED WAS BASED ON ALL ALLOWABLE <br />SOIL BEARING CAPACITY OF 2,000 PSF. TRANSFER REINFORCING (TOP STEEL) HAS <br />BEEN DELETED UNLESS NOTED OTHERWISE. <br />14. VERTICAL REINFORCING IN CMU SHALL BE #5'S AS SHOWN ON THIS PLAN, UNLESS <br />OTHERWISE NOTED IN THE PLAN. ONE REINFORCING BAR SHALL BE: <br />A) IN ALL WALL INTERSECTIONS B) CHANGES IN ELEVATION <br />C) EACH SIDE OF ALL OPENINGS D) ALL CORNERS <br />15. STRUCTURAL DESIGN IS IN ACCORDANCE WITH TMS 4021602-16, BUILDING CODE <br />REQUIREMENTS FOR MASONRY STRUCTURES AND THE COMMENTARY. CONSTRUCTION <br />SHALL BE IN ACCORDANCE WITH TMS 4021602-16. USING: F'm = 2,000 PSI, TYPE "M" OR"S" <br />MORTAR, ASTM C476 GROUT (3000 PSI), UNITS LAID IN RUNNING BOND. <br />16. WIRE WELDED MESH LOCATED IN THE MIDDLE TO UPPER } OF SLAB SUPPORTED <br />T-0" O/C MAX. SEE PLAN FOR W WM SIZE. <br />INSPECTOR NOTE: <br />1. STRUCTURE WAS DESIGNED BASED ON THE 2020 FLORIDA RESIDENTIAL BUILDING <br />CODE, RESIDENTIAL, 7lh EDITION <br />SLAB SCHEDULE <br />SLAB <br />THICKNESS <br />REINF. <br />REMARKS <br />11x6 W 1.4xW 1.4 OVER <br />3 1/2" <br />6 MIL VAPOR <br />COMPACTED FILL <br />BARRIER <br />FOOTING SCHEDULE <br />PROVIDE CORNER BARS SAME SIZE QUANTITY AS BARS IN FOUNDATION WITH NT LEG EACH WAY. <br />MARK <br />WIDTH <br />LENGTH <br />THICKNESS <br />BOTTOM REINF. <br />TOP REINF. <br />T.O.F. <br />SHORT <br />LONG <br />FMA6x18 <br />16' <br />CONTINUOUS <br />18" <br />- <br />(2)#5's <br />FMC-16x18 <br />16' <br />CONTINUOUS <br />18" <br />(2)#519 <br />VARIES <br />TE-1 <br />8" <br />SEE PLAN <br />8" <br />- <br />(1) #5's <br />TE-2 <br />12" <br />SEE PLAN <br />1U" <br />- <br />( s <br />F-24x24 <br />24" <br />24" <br />17 <br />(2) #5's <br />() #Vs <br />F2-24x24 <br />24" <br />24" <br />16, <br />(2)#66 <br />(21 ift <br />- p•.0•• <br />CW-16X12 <br />16" <br />CONTINUOUS <br />17. <br />- <br />(2)#5's <br />(+K"" <br />CWC-i6X12 <br />16 <br />CONTINUOUS <br />1T <br />- <br />(2)#6s <br />#51N CURB <br />VARIES <br />F1-30X30 <br />1 30" <br />1 301, <br />1 12" <br />(3)/!`i's <br />(3)#5's <br />Ft-2024 <br />1 24" <br />1 24" <br />1 12" <br />(2)#6s <br />(2)#5's <br />FOUNDATION PLAN <br />SCALE: 1/4" = V-0" <br />Il N. RONALD REAGAN BL <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-7744078 <br />www.abdesigngroup.com <br />AA fh 0003326 <br />g <br />o <br />tmwv. ae LOT <br />ABBOTT PARK <br />LOT #26 <br />BLK. #12 <br />PROJECT <br />04181.006-26121 <br />acOaEu <br />3EEB <br />"2260-ELSTON" <br />GARAGE STFING: <br />RIGHT <br />PAGE: <br />FOUNDATION <br />PLAN <br />160 MPH & C <br />B <br />m <br />PRINT <br />6/14/21 <br />SCALE: 1/4"=1'-0" <br />SIMET <br />S1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.