My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7547 Sail Clover Ln
Zephyrhills
>
Building Department
>
Building Plans
>
7547 Sail Clover Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 12:17:23 PM
Creation date
2/24/2025 9:42:44 AM
Metadata
Fields
Template:
Building Plans
Street #
7547
Location
Sail Clover Ln
Contractor
D R Horton
Building Plans - Permit #
4587
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />1. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />I'M. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS PAS 4 MASTIC. AND <br />INSTALLED AS PER FBC 1TH EDITION (2020) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NFPA 90A 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER PBC 1TH EDITION (2020) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED M ACCORDANCE TO POO 1TH EDITION <br />(2020) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 1TH EDITION (2020) MECHANICAL CODE SECTION <br />403. <br />8. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9. ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER. ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND PBC 1TH <br />EDITION (2020) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11. DRYER BOOSTER TO BE A FANTEC44 DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TRUNK <br />BALANCING DAMPER OR OBD <br />0 <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />m <br />PASS-THRU AIR GRILL <br />NOTE <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />ATTIC <br />CEILNG <br />O <br />O <br />EXTERIOR WALL <br />PLENUM <br />T <br />y <br />AIR RETURN <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />SECURE STRAP TO CON_. <br />W/ (2)-3/16'X2' TAPCONS <br />CONDENSER <br />UNIT <br />SIMPSON WB ROLL STRAP <br />y <br />OR EQUAL <br />AIR HANDLER <br />EXTERIOR WALL <br />y <br />3/4' PVC CONDENSATE DRAIN LINE <br />SECURE STRAP TO WIT W/ (2) <br />EVAR TRAY <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />4' CONCRETE SLAB %XI 1/4' SHT. MTL. SCREWS <br />TO <br />CONDENSER UNITNES <br />PLATFORM <br />RETURN <br />CONDENSING IT <br />CONDENSING WIT <br />TRAP DRAIN LINE AND TERMINATE <br />CONNECTION TO PAD <br />MAN APRovED DRAIN, PER <br />FBCR TTN EDITION (2020) <br />NOTE: MAN COND. DRAM 3/4' DIA. <br />MECHANICAL BLDG. CODE <br />SECTION 301].4 <br />OVER HEAD • FROM STRUCTURE <br />HVAC <br />DRAINS <br />SCORIATED NICKEL /- FIN. FLOOR <br />BRONZE FL. PL. / OR WALL <br />BRASS PLUG <br />FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />WADE 8240-K JOSAM 96000 <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.V.0 OPTI/SPEG <br />FLOOR SLAB CLEAN -OUT fTYF ) <br />COUNTERSUNK <br />C.O. PLUG <br />FIN. GRADE <br />OR PAVING <br />SEE SPEC. <br />I'-8'XS' CONC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />NEXT. GROUND CLEAN -OUT (TYP. <br />N <br />I I----------� <br />I <br />I <br />I <br />8' <br />%MG <br />FROM O <br />xvvm <br />BEDROOM AEVE <br />I---�� <br />12X8 +---------- <br />--------' 1j } <br />m I <br />--- 14X6 12X12 II I I ^I3 <br />PASS I <br />BATH 92 TNIOJ II I) I I � <br />7�----II.1 • <br />------------- <br />- - - - - - C <br />•: <br />I I I I I I I I I I' x• <br />SKITCHEN <br />TOR.I <br />I <br />OWH <br />o <br />GARAGE <br />DXX4 12X8 <br />S' S/A <br />FROM <br />u <br />ABOVE <br />W m , <br />sxs . <br />nl .FLEX <br />FOYER <br />III <br />� III <br />PORCH <br />FIRST FLOOR MECHANICAL PLAN <br />SCALE, 1/4 • I'-& <br />1 N. RONALD REAGAN BI <br />LONGWOOD, FL32750 <br />PH: 407-7746078 <br />FAX: 407-774.4078 <br />www.abdesigngroup.com <br />AA #: 0003326 <br />y <br />SVHDM ac LOT <br />ABBOTT PARK <br />LOT #7 <br />BLK. #12 <br />PHASE 4C <br />PROJECT# <br />04181.04C-07121 <br />MODEU <br />4EHB <br />"2605— HAYDEN" <br />GARAGE BVIMC : <br />LEFT <br />PAGE: <br />FIRST FLOOR <br />MECHANICAL <br />PLAN <br />160 MPH EXP. C <br />DATE: 12/27/21 <br />sCALX: 1/4"=1'-0" <br />SHEET <br />M1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.