Laserfiche WebLink
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MPG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS $HALL, BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER FBC ITH EDITION (2020) MECHANICAL BLDG, CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, $HALL. BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC ITH EDITION (2020) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FDC ITO EDITION <br />(2020) MECHANICAL CODE 6O3J <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR DATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH F9C 1TH EDITION (2020) MECHANICAL CODE SECTION <br />403. <br />8. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />3 ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND ISE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC ITH <br />EDITION (2020) MECHANICAL CODE SECTION 601. <br />W. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />II. DRYER BOOSTER TO BE A PANTEC4 DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFRJSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TRUNK <br />l <br />BALANCING DAMPER OR ODD <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />m <br />PASS-THRU AIR GRILL <br />IS= <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />SECURE STRAP TO CONC. CONDENSER <br />ATTIC <br />W/ (2)-3A6'X2' TAPCONS UNIT <br />SIMPSON WB ROLL STRAP <br />OR EQUAL <br />CEILING <br />O O <br />EXTERIOR WALL <br />PLENUM <br />y <br />AIR RETURN <br />4' CONCRETE SLAB <br />SECURE STRAP TO UNIT W/ (2) <br />•SXI 1/4' SPIT. MTL. SCREWS <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />CONDENSER <br />UNIT <br />AIR HANDLER <br />y <br />CONNECTION <br />TO PAD <br />EXTERIOR WALL <br />y <br />3/4' PVC CONDENSATE DRAIN LINE <br />NOTE: MAIN COND. DRAIN 3/4' DIA. <br />OVER HEAD 4 12' FROM STRUCTURE <br />EVAR TRAY:,, <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />T <br />REFRIGERANT LINES TO <br />PLATFORM <br />RETURN <br />CONDENSING UNIT <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />FBCR ITH EDITION (2020) <br />MECHANICAL BLDG. CODE <br />SECTION 3Ol].4 <br />HVAC <br />DRAINS <br />SCORIATED NICKEL <br />BRONZE FL. PL. <br />� <br />FIN. FLOOR <br />OR WALL <br />COUNTERSUNK <br />C.O. PLUG <br />� <br />__SEESPEC. <br />BRASS PLUG <br />�-FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />WADE 8240-K JOSAM 56WO <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.V.0 OPTVSPEC <br />FLOOR SLAB CLEAN -OUT (T_Y <br />FIN. GRADE <br />OR PAVING <br />I'-S'X8' CONC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />NEXT. GROUND CLEAN -OUT (TYP. <br />N <br />MECHANICAL PLAN <br />SCALE. 1/4 • P-V <br />NOTE: <br />ALL MECHANICAL EQUIPMENT <br />SHALL BE INSTALLED AT OR <br />ABOVE F.P.E. ELEVATION. <br />■ <br />is <br />I alp <br />1441 N. RONALD REAGANJBLVD.LONGWOOD, FL327PH: 407-7746078 <br />FAX: 407.774-4076www.abdesigngroup.c <br />AA #: 0003325 <br />dJ <br />k <br />SUBDIV. & Lotil <br />ABBOTT PARK <br />LOT#4 BLK#14 <br />PHASE 4C <br />PROJECT# <br />04181.04C-04141 <br />MODELa <br />4EAB <br />"1672-ARIA" <br />GARAGE BWn4G: <br />RIGHT <br />PAGE: <br />MECHANICAL <br />PLAN <br />%160 MPH EXP. C <br />