My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7602 Sail Clover Ln
Zephyrhills
>
Building Department
>
Building Plans
>
7602 Sail Clover Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 3:58:21 PM
Creation date
2/24/2025 9:30:34 AM
Metadata
Fields
Template:
Building Plans
Street #
7602
Location
Sail Clover Ln
Contractor
D R Horton
Building Plans - Permit #
4463
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />1. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MPG. REQUIREMENTS, <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FACT l MASTIC. AND <br />INSTALLED AS PER FBC 1TH EDITION (2020) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 04 CLASS I AIR DUCT AS PER NFPA WA 2-5.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC TtH EDITION (2020) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FOO IN EDITION <br />(2020) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTU06, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC IN EDITION (2020) MECHANICAL CODE SECTION <br />403. <br />8. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9 ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MPG. RECOMMENDATIONS AND FBC IN <br />EDITION (2020) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DFRJ&ERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11. DRYER BOOSTER TO BE A PANMC 4 DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DFFUSER <br />— <br />SOLID LINE. SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TRUNK <br />I <br />BALANCING DAMPER OR OBD <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 1 LIGHT <br />O/A <br />OUTSIDE AIR <br />0 <br />THERMOSTAT <br />m <br />PASS-THIO) AIR GRILL <br />NOTE, <br />ALL HVAC TO HAVE PROPER <br />PAN& W/ DRAINS <br />ATTIC <br />CEILING <br />O <br />O <br />EXTERIOR WALL <br />PLENUM <br />T <br />1 <br />AIR RETURN <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />SECURE STRAP TO CONC. <br />W/ (2)-3/1650' TAPCONS <br />CONDENSER <br />UNIT <br />SIMPSON WB ROLL STRAP <br />y <br />OR EQUAL <br />AIR HANDLER <br />EXTERIOR WALL <br />1 <br />3/4' PVC CONDENSATE DRAIN LINE <br />YI—SECURE STRAP TO UNIT UI/ (2) <br />EVAP. TRAY <br />1 <br />PVC SLEEVE TO LINES BELOW SLAB <br />4' CONCRETE SLAB 1SXI 1/4' $HT. MTL. SCREWS <br />REFRIGERANT REFRIGERANT LINES TO <br />CONDENSER UNIT <br />PLATFO <br />RETURN <br />CONDENSING UNIT <br />TRAP DRAIN LINE AND TERMINATE <br />CONNECTION TO PAD <br />DRAIN, PER <br />IN AN FBN EDITION <br />GR 1TH EDITION (2020)) <br />NOTE, MAIN COND. DRAIN 3/4' DIA. <br />MECHANICAL BLDG. CODE <br />SECTION 3017.4 <br />OVER HEAD • 12' FROM STRUCTURE <br />HVAC <br />DRAINS <br />SCORIATED NICKEL FIN. FLOOR <br />BRONZE FL. PL. OR WALL <br />E-T2T_'-r>1i� <br />--"'�--FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />WADE 6240-K JOSAM 56000 <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.V.0 OPTI/SPEC <br />vFL00R SLAB CLEAN -OUT (TY <br />COUNTERSUNK <br />C.O. PLUG <br />FIN. GRADE <br />OR I*AvWs <br />SEE SPEC. <br />o' CONC. <br />FITTING OR <br />EXTENSION t0 SOIL <br />OR WASTE AS <br />REQUIRED <br />2 XAT. GROUND CLEAN -OUT (TYQ <br />I <br />r---------71 <br />I <br />I <br />I <br />DIM r <br />14' FROM <br />OM <br />I xuu� <br />BEDROOM <br />1 I III 1 II I I�------ 1 l <br />1 >1 <br />I I 12X12 m <br />— — — — — — <br />PASS <br />TNRU jar <br />D ' I I ----------------- I----�v <br />I -- I 80 <br />OEM <br />IGTCHEI <br />I I I sTOR• I I I <br />I <br />1 <br />II WH <br />12X8 f ✓8�4 <br />S' &/A <br />�� II FROM <br />ABOVE <br />III <br />II FOYER <br />III <br />III <br />- - - GARAGE <br />I <br />I <br />I PORCL ------- H <br />---- --------------- <br />FIRST FLOOR <br />MECHANICAL PLAN <br />SCALE, V4 . P-0• <br />11 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407.7746078 <br />FAX: 407.7744078 <br />www.abdesWigroup.com <br />AA M: 0003325 J <br />o <br />� <br />o <br />di <br />avaasv. as Lrom <br />ABBOTT PARK <br />LOT #2 <br />BLK #14 <br />PHASE 4C <br />PROD=T# <br />041 1.04C— 2 41 <br />awDau <br />4EHB <br />"2605— HAYDEN" <br />GARAOX O IINM <br />RIGHT <br />PAGW. <br />FIRST FLOOR <br />MECHANICAL <br />PLAN <br />160 MPH EXP. C <br />