HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG, REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED N NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB s MASTIC. AND <br />INSTALLED AS PER FBC 1TH EDITION (2020) MECHANICAL BLOG, CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL ISI CLASS I AIR DUCT AS PER PFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN IO FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />S. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, $HALL. BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC iTH EDITION (2020) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 1TH EDITION <br />(2020) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH POO 1T14 EDITION (2020) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9 ALL FIRE RATED CEILINGS AND WALLS 844ALL. HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC 1TH <br />EDITION (2020) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH 15ALANCNO DAMPERS. <br />II. DRYER BOOSTER TO BE A FANTEC 4 DBF BOOSTER FAN OR EQUAL. <br />PANTEC 4 DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE. SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TRUNK <br />BALANCING DAMPER OR 000 <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN s LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />® <br />PASS-THRU AIR GRILL <br />NOTE, <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />ATTIC <br />CEILhyG <br />O <br />O <br />EXTERIOR WALL <br />PLENUM <br />y <br />AIR RETURN <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />y <br />AIR HANDLER <br />EXTERIOR WALL <br />SECURE STRAP TO PS <br />T <br />UNIT <br />SIMPSON WB ROLL STRAP THRUNSER <br />y <br />3/4' PVC CONDENSATE DRAIN LINE <br />OR EQUAL WALL <br />EVAP. TRAY <br />y <br />PVC SLEEVE TO LINES BELOW BLAB <br />PLATFORM <br />T <br />RETURN <br />REFRIGERANT LINES TO <br />CONDENSING UNIT <br />4' CONCRETE SLAB SECURE STRAP TO WIT W/ (2) <br />'SXI 1/4' SHT. MTL. SCREWS <br />TRAP DRAIN LINE AND TERMINATE <br />N AN APREDED DRAM,PER <br />CONDENSER UNIT <br />FBCR 1TH EDITION (2020)) <br />MECHANICAL BLDG CODE <br />SECTION 3017.4 <br />CONNECTION TO PAD <br />HVAC <br />DRAINS <br />NOTE- MAIN CONO. DRAIN 3/4' DIA. <br />OVER HEAD • 12' FROM STRICTURE <br />SCORIATED NICKEL FIN, FLOOR COUNTERSUNK <br />BRONZE FL. PL. OR WALL CA, PLUG <br />BRAGS PLUG <br />�"—FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />WADE 8240-K JOSAM 96000 <br />INSIDE SERIES NICKEL DRAW TOP <br />CAULK P.VJC OPTVSPEC <br />OFLOOR SLAB CLEAN -OUT TYPE <br />FIN. GRADE <br />OR PAVING <br />SEE SPEC. <br />1'-81xs' CONC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />nEXT. GROUND CLEAN -OUT TYPN <br />FIRST FLOOR MECHANICAL PLAN <br />SCALE: 1/4 . 1'-0' <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL32780 <br />PH: 407-774-6078 <br />FAX 407-7744078 <br />www.abdoslgngroup.00m <br />_--- AAM:0003325 _ J <br />wig <br />BtMDM ds IIAT' <br />ABBOTT PARK <br />LOT #29 <br />BLK #11 <br />PROJECT# <br />04181.000-29111 <br />MoaE1a <br />AISLE" <br />2007 <br />GARAGE BWMG: <br />RIGHT <br />PAGE: <br />FIRST FLOOR <br />MECHANICAL <br />PLAN <br />60 MPH <br />