GENERAL NOTES <br />1. ALL WORK DONE UNDER THIS CONTRACT SHALL BE IN COMPLIANCE WITH THE FLORIDA BUILDING CODE RESIDENTIAL (FBCR) <br />7th EDITION, (202D) . ALL REFERENCED CHAPTERS, CODE SECTIONS AND TABLES STATED IN THESE DOCUMENTS ARE UNDER <br />FBCR 7TH EDITION (2020) UNO. <br />2. WHERE BUILDING LOCATIONS ARE DETERMINED TO BE IN WAND BORNE DEBRIS REGIONS, ALL EXTERIOR <br />BUILDING OPENINGS SUCH AS WINDOWS AND DOORS SHALL BE PROTECTED AGAINST WINDBORNE DEBRIS BY <br />THE INSTALLATION OF STRUCTURAL PANELS OR IMPACT -RESISTANT GLASS. THESE OPENING PROTECTIONS SHALL BE <br />DESIGNED AND INSTALLED IN ACCORDANCE WITH FBCR 2020 CHAPTER 3, SECTION R301.21.2. <br />3. DO NOT SCALE DRAWINGS. THE CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO WORK <br />PERFORMED AND SHALL NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND. <br />4. THE CONTRACTOR SHALL BRING ERRORS AND OMISSIONS WHICH MAY OCCUR IN CONTRACT DOCUMENTS TO THE ATTENTION <br />OF THE ARCHITECT IN WRITING AND WRITTEN INSTRUCTIONS SHALL BE OBTAINED BEFORE PROCEEDING WITH THE WORK. <br />THE CONTRACTOR WALL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY ERRORS, DISCREPANCIES OR OMISSIONS IN THE <br />CONTRACT DOCUMENTS, OF WHICH THE CONTRACTOR FAILED TO NOTIFY THE ARCHITECT BEFORE CONSTRUCTION ANDKNR <br />FABRICATION OF THE WORK, <br />5. THE ARCHITECT/ENGINEER SHALL NOT BE RESPONSIBLE FOR THE SAFETY AND CONSTRUCTION PROCEDURES, TECHNIQUES, <br />OR THE FAILURE OF THE BUILDER TO CARRY OUT THE WORK IN ACCORDANCE WITH THE DRAWINGS OR THE REQUIRED CODES. <br />6. THE STRUCTURAL DESIGN IS BASED ON THE INTERACTION OF ALL PARTS OF THE COMPLETED BUILDING. THE CONTRACTOR <br />SHALL SOLELY BEAR THE RISK FOR PROVIDING ADEQUATE STABILITY AND SAFETY OF THE STRUCTURE DURING <br />CONSTRUCTION UNTIL PERMANENT MEMBERS ARE COMPLETELY INSTALLED. <br />7. DETAILS SHOWN ON THE DRAWINGS ARE TO BE CONSIDERED TYPICAL FOR ALL SIMILAR CONDITIONS. <br />8. THE CONTRACTOR SHALL MAKE NO STRUCTURAL CHANGES WITHOUT WRITTEN APPROVAL FROM THE ARCHITECTIENGINEER <br />9. NO STRUCTURAL MEMBERS ARE TO BE CUT FOR PIPES, DUCTS, ETC. UNLESS SPECIFICALLY DETAILED. <br />GARAGES AND CARPORTS <br />1. GARAGE DOOR <br />A. ENGINEERED FOR MIN. WIND LOAD, LISTED ON COVER SHEET <br />B. DETAIL TO BE SUPPLIED BY GARAGE DOOR SUPPLIER <br />C. DETAIL TO BE ATTACHED TO PERMIT PACKAGE BY BUILDER <br />2. AS PER SECTION R3025.1: OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTO A ROOM USED FOR SLEEPING <br />PURPOSES SHALL NOT BE PERMITTED. OTHER OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH <br />SOLID WOOD DOORS NOT LESS THAN 13M INCHES IN THICKNESS, SOLID OR HONEYCOMB CORE STEEL DOORS NOT LESS THAN <br />1-15INCHES THICK, OR 2D-MINUTE FIRE -RATED DOORS. <br />3. AS PER SECTION R3025.2: DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE <br />DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM NO, 25 GAGE (0.48 MM) SHEET STEEL 1-MIN. RIGID <br />ON -META W C CLASS OR CLASS 1 DUCT BOARD OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE <br />GARAGE. <br />4. AS PER SECTION R30268 TABLE R3026: THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC AREA BY NOT <br />LESS THAN %-INCH GYPSUM BOARD APPLIED TO THE GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMS SHALL BE <br />SEPARATED FROM ALL HABITABLE ROOMS ABOVE BY NOT LESS THAN 5 / 8 -INCH TYPE X GYPSUM BOARD OR EQUIVALENT. <br />WHERE THE SEPARATION IS A FLOOR -CEILING ASSEMBLY, THE STRUCTURE SUPPORTING THE SEPARATION SHALL ALSO BE <br />PROTECTED BY NOT LESS THAN'haNCH GYPSUM BOARD OR EQUIVALENT. <br />81TE WORK <br />1. REFER TO THE SOILS REPORT FOR SPECIFIC DESIGN REQUIREMENTS (IF REQUIRED BY BUILDING DEPARTMENT). <br />2. REFER TO THE CIVIL DRAWINGS FOR LOCATION OF BUILDING WORKING POINTS, ROUGH GRADING, ON -SITE UTILITIES, <br />SITE IMPROVEMENTS, SITE RETAINING WALLS, AND SPECIFIC GENERAL NOTES. THE SOILS REPORTAND CIVIL <br />DRAWINGS SHALL OVERRIDE CONFLICTS WITH SITE WORK NOTED HEREIN.SEE LANDSCAPE DRAWINGS FOR FINAL <br />FINISH GRADES, PLANTNGAND IRRIGATION. <br />3. ELEVATIONS SHOWN ON THE SITE DRAWINGS ARE MINIMUM REQUIRED DEPTHS, IF DIFFERENT CONTACT THE <br />ARCHITECT. <br />4. NO EXCAVATION SHALL BE MADE WHOSE DEPTH BELOW THE FOOTING IS GREATER THAN % THE HORIZONTAL <br />DISTANCE FROM THE NEAREST EDGE OF THE FOOTING. <br />5. ALL BACKFILL AT STRUCTURES, SLABS, STEPS, AND PAVEMENTS SHALL BE CLEAN GRANULAR FILL. PLACE IN 8' LAYERS <br />AND COMPACT TO 95%MAXIMUM DRY DENSITY DETERMINED IN ACCORDANCE WITH ASTM D1557-2012El. THE <br />BUILDING SITE SHALL BE KEPT DRY SO THAT EROSION WILL NOT OCCUR IN THE FOUNDATIONS. <br />6. COMPACTION BY FLOODING OR JETTING IS STRICTLY PROHIBITED. <br />7. DO NOT BACKFILL UNTIL SLABS HAVE CURED OR HAVE BEEN PROPERLY BRACED. (WHERE APPLICABLE) <br />8. EXCAVATIONS TO BE A MINIMUM OF 3- 0' BEYOND NEW FOOTING LINE. <br />9. THE GENERAL CONTRACTOR MUST TAKE MEASURES TO CONTROL SOIL EROSION AS PER ALL LOCAL AND STATE <br />REQUIREMENTS. <br />10. THIS BUILDING IS NOT DESIGNED TO BE CONSTRUCTED WITHIN A FLOOD ZONE, LINO. CONTRACTOR IS TO VERIFY THE <br />ELEVATION OF THE FINISHED FLOOR SLAB WITH THE SIGNED AND SEALED SURVEY WHICH COMPLIES WITH ALL LOCAL <br />CODES HAVING JURISDICTION, INCLUDING ALL APPLICABLE STATE, CITY, AND COUNTY BUILDING AND ZONING CODES. <br />11, SWIMMING POOL, DECK, SPA, AND ASSOCIATED WORK IS TO BE PERMITTED SEPARATELY BY ENGINEERED SHOP <br />DRAWING. <br />12, TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING SOIL APPLIED PESTICIDES, <br />BAITING SYSTEMS AND PESTICIDES APPLIED TO WOOD, OR OTHER APPROVED METHODS OF TERMITE PROTECTION <br />LABELED FOR USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION. UPON COMPLETION OF THE <br />APPLICATION OF THE TERMITE PROTECTIVE TREATMENT, A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE <br />BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: <br />'THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. <br />TREATMENT IS IN ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF <br />AGRICULTURE AND CONSUMER SERVICES' <br />Ti <br />1. ALL WOODS AND WOOD CONSTRUCTION SHALL COMPLY WITH SPECIFICATIONS AND CODES MODIFICATIONS AS SPECIFIED <br />HEREIN: <br />A. AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (STANDARDS MANUAL) <br />B. NATIONAL FOREST PRODUCTS ASSOCIATION: <br />1. NATIONAL DESIGN SPECIFICATIONS (NOS) FOR WOOD CONSTRUCTION <br />C. SOUTHERN PINE INSPECTION BUREAU: <br />1. STANDARD GRADING RULES FOR SOUTHERN PINE LUMBER <br />D. TRUSS PLATE INSTITUTE: <br />1. NATIONAL DESIGN STANDARDS FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES (TPI 1-2D14) <br />E. APA- THEENGINEEREDWOODASSOCIATION: <br />I, ENGINEERED WOOD CONSTRUCTION GUIDE <br />F. AMERICAN WOOD PRESERVERS ASSOCIATION STANDARDS <br />2. ALL LUMBER EXPOSED TO WEATHER OR AGAINST SOIL, CONCRETE OR MASONRY MUST BE PRESSURE TREATED. <br />3. MINIMUM NAILING PER CHAPTER 8- WALL CONSTRUCTION AND TYPICAL NAILING SCHEDULE ON PLANS. <br />4. NOTCHING OR CUTTING OF FRAMING MEMBERS SHALLCOMPLY WITH CHAPTER 6- WALL CONSTRUCTION. <br />5. WALL SHEATHING SHALL BE PER STRUCTURAL, SEE ROOFIWALUFLOOR SHEATHING FASTENER SCHEDULE ON SHEET SNI. <br />6. MINIMUM DIMENSION OF ANY PLYW00DSHEET SHALL BE24'AND THE MINIMUM AREA SHALL BE8FT .SQ. <br />PL� <br />1. SANITARY LINES SHALL BE OF CAST IRON OR PVC (SCHEDULE 40) AS APPROVED BY THE BUILDING OFFICIAL. <br />2. WATER SUPPLY ONES SHALL BE CPVC OR UPONOR PEX'A' (CROSS -LINKED POLYETHYLENE) WITH F1960 FITTINGS. <br />3. CONDENSATION LINES SHALL BE MINIMUM'/.' PVC (SCHEDULE 40), INSULATED WITH W AMAFUEX. <br />4. SHOWER HEADS SHALL HAVE A FLOW CONTROL DEVICE TO GIVE A MAXIMUM FLOW OF 2.5 GPM EACH IN ACCORDANCE WITH <br />THE FBCR TABLES 2903.18 2903.2. <br />5. ALL CLEANOUTS SHALL BE FLUSH WITH GRADE. <br />6. NO VENT STACKS SHALL PASS THROUGH ROOF CRICKETS, VALLEYS, OR RIDGES. <br />7. SIZE AND LOCATION OF CLEANOUTS SHALL CONFORM TO FBCR SECTION P3005.2. <br />8. FIXTURE SUPPLY SIZES SHALL CONFORM TO FBCR SECTION P2903. <br />9. THE PLUMBER IS TO DIVERT ALL VENTS TO REAR ELEVATION WHEN POSSIBLE. <br />10. DRILLING 6 NOTCHING OF WOOD FRAMED STRUCTURAL MEMBERS SHALL FOLLOW PROVISIONS OF FBCR SECTION P2603.2. <br />EXTERIOR WALL CWERNSB <br />1. ALL EXTERIOR WALL COVERINGS AND SOFFITS SHALL BE CAPABLE OF RESISTING THE DESIGN PRESSURES SPECIFIED FOR <br />THE WALLS FOR COMPONENTS AND CLADDING LOADS IN ACCORDANCE WITH FBCR TABLE R301.A2) AS MODIFIED BY FBCR <br />TABLE R301.2(3), MANUFACTURED SOFFITS SHALL BE TESTED AT 1.5 TIMES THE DESIGN PRESSURE <br />OITI IR mmNES <br />i. WHEN PLASTERING WITH CEMENT, PLASTER SHALL NOT BE LESS THAN THREE COATS, W THICK, OVER FRAMED WALLS <br />APPLIED OVER PAPER BACKED METAL LATH OR WIRE FABRIC LATH AND WITH TWO LAYERS OF VAPOR BARRIER, NOT LESS <br />THAN 2 COATS,12' THICK, WHERE APPLIED OVER MASONRY OR CONCRETE. <br />2. STUCCO OR PORTLAND CEMENT PLASTER SHALL BE INSTALLED, PROPORTIONED AND MIXED IN ACCORDANCE WITH <br />ASTM-C926.18b, ASTM-C 1063-19a 8 ASTM-C1787. <br />3. LATH 6 ACCESORIES PER ASTM-C-1063.19a 6 R703.7.1. ALL STUCCO APPLICATION DETAILS, INCLUDING BUT NOT LIMITED TO: <br />- ALL STUCCO CONTROL JOINTS - KICK -OUT DETAILS <br />- 'L' FLASHING - HORIZONTAL LATH AND PAPER DETAILS <br />- PIPE PENETRATION DETAILS - VENT PENETRATION DETAILS <br />- WEEP SCREED DETAILS - CONDUIT PENETRATION DETAILS <br />- CASING BEAD DETAILS - DRIP EDGE DETAILS <br />- CANTILEVER DRIP EDGE DETAILS - CORNER BEAD DETAILS <br />- WINDOW CASING DETAILS - STUCCO TO SIDING TRANSITION DETAILS <br />- WINDOW FLASHING DETAILS <br />4. SHALL BE INSTALLED PER ASTM-C 1063 - 19a AND R703.7. <br />FM RESISTANT CONSTRUCTION <br />UNDER STAIR PROTECTION: <br />1. ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER STAIR SURFACE AND ANY SOFFITS PROTECTED <br />ON THE ENCLOSED SIDE WITH 1/7 GYPSUM BOARD. R302.7. <br />EKTENIORCELM <br />1. EXTERIOR CEILING TO BE 12' GOLD BOND BRAND EXTERIOR SOFFIT BOARD INSTALLED PERPENDICULAR TO THE FRAMING <br />MEMBERS. THE 12' GOLD BOND BRAND EXTERIOR SOFFIT BOARD IS TO BE SECURED TO THE FRAMING MEMBERS WITH 1 <br />1/4' TYPE'W DRYWALL SCREWS AT 17 O.C. (PER MANUFACTURER'S SPECIFICATIONS) . <br />CONtTRUCiTON 088E1NAT10N <br />CONSTRUCTION OBSERVATION SERVICES /CONSTRUCTION ADMINISTRATION SERVICES ARE NOT APART OF AB DESIGN GROUPS <br />SERVICES FOR THIS PROJECT. <br />IT IS UNDERSTOOD AND AGREED THAT AS DESIGN GROUP'S SCOPE OF SERVICES DOES NOT INCLUDE PROJECT OBSERVATION OR REVIEW <br />OF THE BUILDERS I CONTRACTORS PERFORMANCE OR ANY OTHER CONSTRUCTION PHASE SERVICES, AND THAT SUCH SERVICES WILL <br />BE PROVIDED BY THE BUILDER THE BUILDER ASSUMES ALL RESPONSIBILITY FOR INTERPRETATION OF THE CONTRACT DOCUMENTS, AND <br />FOR CONSTRUCTION OBSERVATION. <br />EXTE M SOFFITS <br />1. EXTERIOR SOFFITS (ALL REQUIRED SUPPORTS, BRACING, SUPPORT BRACING, ATTACHMENTS, ETC.)ARE TO BE <br />INSTALLED SHALL BE IN COMPLIANCE WITH THE FLORIDA BUILDING CODE RESIDENTIAL (FBCR) 7th EDITION, (2020) R 704.2 <br />SUCH THAT THE SOFFIT IS CAPABLE OF WITHSTANDING THE PRESSURES. <br />CONTROL DATE: 09/08/21 (CM) <br />1 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-7744078 <br />FAX: 407-774 O78 <br />w .ebdesWngrouP mm <br />AA M: 0003325 <br />it <br />9 <br />low <br />e <br />� <br />Elf <br />a <br />Lill <br />s1lrsDiv a. Ti0'h <br />ABBOTT PARK <br />LOT #45 <br />BLK 7 <br />pnonICT# <br />04 1.000-4507 <br />WoDzu <br />4EHB <br />"2605-HAYDEN" <br />OA1tA0Z BWDM: <br />RIGHT <br />PACE: <br />GENERAL <br />NOTES <br />60 MPH E <br />e12� <br />DA M 09/22/21 <br />OCALM 1/4-=1'-0" <br />slat l' <br />GN <br />