My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7652 Broad Pointe Dr
Zephyrhills
>
Building Department
>
Building Plans
>
7652 Broad Pointe Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 6:23:55 PM
Creation date
2/24/2025 9:51:22 AM
Metadata
Fields
Template:
Building Plans
Street #
7652
Location
Broad Pointe Dr
Contractor
D R Horton
Building Plans - Permit #
1734
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL 15E PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MO. REQUIREMENTS, <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SMALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL ISE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER FBC ITN EDITION (2020) MECHANICAL SLOG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL WN CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT 15E LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, $WALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC ITH EDITION (2020) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED N ACCORDANCE TO FSC 1TH EDITION <br />(2020) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, WAS AND SIMILAR BATHING FIXTURES SHALL SE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC ITH EDITION (2020) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9. ALL FIRE RATED CEILINGS AND WALLS 814ALL HAVE AN APPROVED FIRE OR FIRE/BMCKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL SE INSTALLED TO MPG. RECOMMENDATIONS AND FBC ITN <br />EDITION (2020) MECHANICAL CODE SECTION 60I. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />IL DRYER BOOSTER TO BE A PANTEC 4 OBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />SECURE STRAP TO CONC. CONDENSER <br />W/ l2)-3/167Q' tAPCONB WIT SIMPSON US ROLL STRAP <br />OR EQUAL <br />4' CONCRETE SLAB SECURE STRAP TO WIT W/ (2) <br />•SXI 1/4' SHT. MTL. SCREWS <br />CONDENSER UNIT <br />CONNECTION TO PAD <br />NOTE: MAIN COND. DRAIN 3/4' DIA. <br />OVER HEAD • 12' FROM STRUCTURE <br />ATTIC <br />AIR BUPPLY-: <br />AIR HANDLER 1 <br />E VAP. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />m <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TRUNK <br />1 <br />BALANCING DAMPER OR OBD <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />19 <br />PASS-THRU AIR GRILL <br />NOTE <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />EXTERIOR WALL <br />AIR RETURN <br />SUCTION AND LIQUID <br />REF IRKsERANT LINER <br />EXTERIOR WALL <br />3/4' PVC CONDENSATE DRAIN LINE <br />PVC SLEEVE TO LINES BELOW SLAB <br />R REFRIGERANT LINES TO <br />RETURN CONDENSING WIT <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAW, AS PER <br />FBCR ITH EDITION (2020) <br />MECHANICAL BLOG. CODE <br />SECTION W12A <br />HVAC DRAINS <br />SCORIATED NICKEL ///---FIN. FLOOR <br />BRONZE FL. PL. / OR WALL COUNTERSUNK <br />CO. PLUG <br />DRA66 PLUG <br />—"'�—FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />//--WADE 8240-K "AM 56000 <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.V.0 OPTUSPEC <br />FLOOR SLAB CLEAN -OUT (TYPN <br />FIN. GRADE <br />OR PAVING <br />SEE SPEC, <br />I'-S'XS' QDNC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />vEXT. GROUND CLEAN -OUT (T <br />- — — — — — 7 <br />I I <br />I <br />I <br />Dj�I�(G <br />KKVVVVI�n i IFROM m <br />�ABOVE BEDROOM 1�2 <br />ITXS <br />—IriI II-------� — <br />I <br />I I II 12XI2 Im --------- <br />• II <br />II AS --- <br />e I I1. <br />BATH <br />2 <br />DII------------------------�� <br />"!I I <br />KITCHEN '�X it <br />��� I I I <br />I I I sTOR. I I I <br />I <br />0s <br />I i <br />12XB m <br />�♦ III � <br />� III <br />FLEX III FOYER <br />III <br />ul /O <br />S' S/A <br />FROM <br />ABOVE <br />GARAGE <br />FIRST FLOOR <br />MECHANICAL PLAN <br />SCALE: 1/4 • I'-& <br />FEB <br />• <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774.6078 <br />FAK 407-7744078 <br />www.abdesigngmup.com <br />AA is 000332E <br />Ila <br />sunDm Ae LOT: <br />ABBOTT PARK <br />LOT #38 <br />BLK #12 <br />PROJECT <br />04181.00E-38121 <br />I�coaEL: <br />4EHB <br />"2605— HAYDEN" <br />GARAGE 8WD9G: <br />RIGHT <br />PAGE: <br />FIRST FLOOR <br />MECHANICAL <br />PLAN <br />60 MPH EXP. <br />
The URL can be used to link to this page
Your browser does not support the video tag.