My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7656 Sail Clover Ln
Zephyrhills
>
Building Department
>
Building Plans
>
7656 Sail Clover Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 6:29:28 PM
Creation date
2/24/2025 9:29:24 AM
Metadata
Fields
Template:
Building Plans
Street #
7656
Location
Sail Clover Ln
Contractor
D R Horton
Building Plans - Permit #
3340
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />L ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MPG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL, BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS PAS 4 MASTIC. AND <br />INSTALLED AS PER FBC TTH EDITION (2020) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS $HALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT ME LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />S. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH C%ALV. METAL. <br />OR OTHER MATERIALS AS PER FBC TTH EDITION (2020) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS &HALL BE CONSTRUCTED IN ACCORDANCE TO FBC TTH EDITION <br />(2020) MECHANICAL CODE 603.1 <br />T. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC TTH EDITION (2020) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />3 ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO I'M. RECOMMENDATIONS AND FBC TTH <br />EDITION (2020) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />II. DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />1TE• <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAMS <br />ATTIC <br />CEILING <br />O O <br />EXTERIOR WALL <br />PLENUM <br />T y <br />AIR RETURN <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />d <br />REFRIGERANT LINES <br />y <br />AIR HANDLER <br />EXTERIOR WALL <br />y <br />3/4' PVC CONDENSATE DRAIN LINE <br />EVAP. TRAY <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />T <br />REFRIGERANT LINES TO <br />PLATFORM <br />RETURN <br />CONDENSING UNIT <br />TRAP DRAM LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />FBCR TTH EDITION (2020) <br />MECHANICAL BLDG. CODE <br />SECTION 3012A <br />HVAC <br />DRAINS <br />SCORIATED NICKEL /-FIN. FLOOR <br />BRONZE FL. PL. / OR WALL <br />BRASS PLUG <br />FITTING OR EXTENSION TO <br />&OIL OR WASTE A8 <br />REQUIRED <br />//--WADE 8240-K JOSAM 56WO <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.V.0 OPTUSPEC <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR 1 WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TRUNK <br />l <br />BALANCING DAMPER OR OBD <br />4 <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LK+HT <br />O/A <br />OUTSIDE AIR <br />(D <br />THERMOSTAT <br />m <br />PAW-THIR U AIR GRILL <br />SECURE STRAP TO CONC. CONDENSER <br />W/ (2)-3/16'X2' TAPCCNB UNIT SIMPSON WB ROLL STRAP <br />OR EQUAL <br />4' CONCRETE SLAB SECURE STRAP TO UNIT W/ e2) <br />48x1 I/d' BHt. MTL. SCREWS <br />CONDENSER UNIT <br />CONNECTION TO PAD <br />NOTE. MAN COND. ORAN 3/4' DIA. <br />OVER HEAD • 12' FROM STRUCTURE <br />COUNTERSUNK <br />C.O. PLUG <br />FIN. GRADE <br />OR PAVING <br />SEE SPEC. <br />1'-S'X8' CONC. <br />FITTING OR <br />E1; ION <br />TO SOIL <br />OR WASTE A5 <br />REQUIRED <br />OFLOOR SLAB CLEAN -OUT (TYU NEXT. GROUND CLEAN -OUT (TYPN <br />MECHANICAL PLAN <br />SCALE, 1/4 . P-O' <br />NOTE. <br />ALL MECHANICAL EQUIPMENT <br />SHALL BE INSTALLED AT OR <br />ABOVE F.P.E. ELEVATION. <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL32750 <br />PH: 407-774-6078 <br />FAX: 407-7744078 <br />www.abdesWngroup.mm <br />AA #: 0003325 <br />a <br />a <br />4 <br />IA <br />sulwiv. SagLAT: <br />BBOTT PARK <br />LOT #8 <br />BLK. #13 <br />PROJECT <br />041 1.000-08131 <br />"00219 <br />4EBB <br />"1828-CALI" <br />GARAGE R WDFG: <br />RIGHT <br />PAGE: <br />MECHANICAL <br />PLAN <br />160 MPH DR. C <br />2 <br />DA � 9/21/21 <br />SCALE: 1/4"=1'-0" <br />BHZZT <br />M1 <br />