My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7656 Sail Clover Ln (2)
Zephyrhills
>
Building Department
>
Building Plans
>
7656 Sail Clover Ln (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 6:37:30 PM
Creation date
2/24/2025 9:55:09 AM
Metadata
Fields
Template:
Building Plans
Street #
7656
Location
Sail Clover Ln
Contractor
D R Horton
Building Plans - Permit #
3340
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A N C N I T N B T i <br />HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER <br />CLEARANCE, FOR SERVICING PER MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE <br />CONSTRUCTED OF A VALUE OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL <br />BE SEALED WITH GLASS FAB 4 MASTIC. AND INSTALLED AS PER MECHANICAL <br />PROVISIONS OF THE F5CR 6TH EDITION (20I1). <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLASS 1 AIR DUCT AS PER <br />NFPA WA 2-3J <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM <br />ANY CHIMNEY OR VENT OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF <br />SMOOTH GALV. META- OR OTHER MATERIALS AS PER MECHANICAL PROVISIONS <br />OF THE PBCR 6TH EDITION (2011) <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN <br />ACCORDANCE TO THE MECHANICAL PROVISIONS OF FBCR 6TH EDITION (2011) <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, WAS AND SIMILAR BATHING <br />FIXTURES SHALL BE MECHANICALLY VENTED IN ACCORDANCE W/ MECHANICAL <br />PROVISIONS OF THE POOR 6TH EDITION (2011) <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR <br />MAKE-UP AIR TO BE RETURNED, TO EQUAL AIR EXHAUSTED. <br />9. ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE <br />OR FIRE/SMOKE OAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND <br />BE SLEEVED WITH ACCESS DOORS TO RESET DAMPER ALL DAMPERS SHALL BE <br />INSTALLED TO MFG. RECOMMENDATIONS AND MECHANICAL PROVISIONS OF THE <br />P1WR 6TH EDITION (2011) <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH 15ALANCNG DAMPERS. <br />11. DRYER BOOSTER TO DE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH POP 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX SIX <br />ELBOWS. <br />SECURE <br />STRAP TO <br />A/C <br />CONC. W/ <br />SIMPSON W5 <br />UNIT <br />(2)-3/16' x 2' <br />ROLL STRAP <br />TAP -CONS <br />OR EQUAL <br />TOP OF SLAB <br />AT OR ABV. FF.E. <br />Cow — <br />SLAB <br />SECURE STRAP TO <br />UNIT W/ (2) 99od 1/4' <br />SHEET METAL SCREWS <br />A/C <br />CONNECTION <br />TO <br />PAD DETAIL <br />COUNTERSUNK <br />CO. PLUG <br />FIN. GRADE <br />OR PAVING <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LNEe RETURN TRUNK <br />l <br />BALANCING DAMPER OR 050 <br />0 <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 L1044T <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />m <br />PASS-THRU AIR GRILL <br />SEE SPEC. <br />P-8'X8' CONC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />NEXT. GROUND CLEAN -OUT (TYPE <br />BDRM #2#2 <br />II �I II UI <br />GARAGE <br />GREAT <br />ROOM <br />14x11 <br />x <br />12' S/A <br />3 FROM <br />ABovE ��ll <br />------------- <br />I I <br />I I <br />I I <br />COVERED <br />LANAI <br />I I <br />I I <br />I I <br />I I <br />KITCHEN <br />I <br />i <br />� II <br />i <br />I <br />CAFE e <br />I II® <br />II e <br />II � <br />I � <br />I <br />i <br />x 8 <br />0x10 <br />01 <br />L 4 � 8x4 <br />0' $/A LP�PAlNTRY <br />FROM <br />ABOVE <br />5 l <br />O <br />II <br />v <br />x <br />� II x <br />II <br />FOYER <br />II FLEX <br />ROOM <br />II <br />II <br />II <br />_ n <br />ALLL H AVAC TO HAVE PROPER <br />it <br />I <br />ENTRY ENTRY <br />PANS W/ DRAINS <br />I <br />ATTIC <br />I <br />------ --------------- <br />CEILING <br />SCORATEO NICKEL <br />FIN. FLOOR <br />O <br />O <br />EXTERIOR WALL <br />BRONZE FL. PL. <br />OR WALL <br />PLENUM <br />T <br />y <br />AIR RETURN <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />y <br />REFRIGERANT LINER <br />BRASS PLUG <br />y <br />AIR HANDLER <br />EXTERIOR WALL <br />FITTING OR EXTENSION TO <br />El <br />y <br />3/4' PVC CONDENSATE DRAIN LINE <br />SOIL OR WASTE AS <br />REQUIRED <br />EVAR TRAY <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />WADE 8240-K JOSAM 560M <br />T <br />REFRIGERANT LINES TO <br />INSIDE <br />SERIES NICKEL BRASS TOP <br />PLAN <br />RETURN <br />CONDENSING UNIT <br />CAULK <br />P.V.0 OPTI/SPEC <br />FIRST FLOOR <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APCAL P DRAIN, S PER <br />MECHANICAL PROVISIONS OF THE <br />INN. E <br />MECHANICAL <br />PLAN <br />F5CR 6TH EDITION (2011) <br />SI PLAN <br />WALE, 1/4'.I'-0' <br />HVAC <br />DRAINS <br />(I)FLOOR <br />SLAB CLEAN -OUT (TYPN <br />Grou i In <br />c. <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-7748078 <br />FAX: 407-7744078 <br />www.abdeW"oup.com <br />AA N: 0003325 <br />IF DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 8134W2828 <br />FAX: 813.888-2802 <br />>lumviV. a. LOT <br />SILVERADO <br />LOT#8 <br />BLK 13 <br />[PROJZCT# <br />03719.000-08131 <br />MODEM& <br />JORDYN <br />GwRAGIC BWMCI: <br />LEFT <br />PACK: <br />FIRST FLOOR <br />MECHANICAL <br />PLAN <br />11, 150 MPH EXP. C <br />