Laserfiche WebLink
INSTALL 6' SELF-ADHERMG <br />MEMBRANE FLASHING OVER <br />TOP, SIDE(S) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />gEty more OF FLASHING TO 6E: <br />- <br />• : X: <br />I. BOTTOM. 2, SIDES. 3. TOP <br />VENT CAP IS TO BE SET IN BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT 16 TO ISE <br />1: <br />TOOLED SO AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />JOINTS AND INTERSECTIONS <br />�- <br />APPLY SEALANT AT PERIMETER OF <br />BACKER ROD <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDES, Y♦' CAULKING • JOINT <br />ALL AROIMD <br />I <br />PER SECTION <br />EKWft lathing and *s%dng <br />BACKER ROD <br />Exterior use of portland cement plaster <br />shall comply with the application <br />requirements of ASTM C 926.18b. <br />X <br />Installation of extedor lathing and framing <br />shall comply with ASTM C 1063-19a, <br />I)' <br />or ASTM1787. <br />WRB LAYER'(, <br />STUCCO WRAP <br />,I <br />HOODED VENT <br />THICK, 3 COAT CEMENT <br />I, <br />PLASTER <br />METAL LATH <br />WRB LAYER -2, FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER VENT <br />(FRAME) <br />WOOD SHEATHING <br />LAYER 'I, <br />STUCCO WRAP <br />LAYER 4, FORTIFIBER <br />—� BUILDING PAPER <br />CONSTUCTION \ <br />"METAL LATH <br />a' CM VINYL CASING DEAD <br />6' RAISED BAND <br />N,' TO )f' MID -WALL <br />VEEP aCIQED <br />6' WIDE STRIP SELF <br />ADHESIVE FLASFIING, CLEAN <br />MASONRY BEFORE APPLYING <br />Z FLASHING <br />STONE VENEER <br />OVER SCRATCH COAT <br />HORIZONTAL WEEP SCREED <br />W/STONE VENEER <br />(FRAME TO BLOCK) <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER 02 (FORTIFIBER ...... <br />— — <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />WOOD OR 'l/I6" ZIP WALL <br />SHEATHING <br />SELF-ADHESIVE FLASHING — — — — — <br />NOTE: <br />_ METAL LATH: LATH TO BE PER SECTION <br />R103.1.1 / ASTM C-641-14a, MIN. 2B LBS. <br />PER 90. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />FINISH <br />b' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />FLASHING <br />UNIT <br />PREMANUR DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT • <br />TOP i SIDES <br />© DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'MICK <br />FLASH' <br />PIPE THROUGH / <br />WALL <br />l <br />6' SELF ADHESIVE — <br />FLASHING (INSTALL <br />PER MAN1F. SPECS.) <br />BUILDING PAPER <br />UNDER 'MICK FLASH' <br />A VENT PENETRATION <br />SCALE: N.T.S. <br />ELEC. METEf <br />VERIFY LO <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />CONSTRUCTION <br />WOOD SHEATHING <br />WRB LAYER "I, <br />STUCCO WRAP <br />WRB LAYER "Z, FORTIFIBER <br />BUILDING PAPER <br />J' THICK, 3 COAT CEMENT <br />PLASTER <br />Ya' TO Ys' MID -WALL <br />WEEP SCREED <br />�6' SELF-ADHESIVE <br />FLASHING <br />WOOD FRAMED <br />WALL <br />HORIZONTAL WEEP SCREED <br />(FRAME TO FRAME) <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />-('GREAT STUFF' OR SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />PROVIDE STUCCO SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />WOOD SHEATHING <br />LAYER 1, <br />STUCCO WRAP <br />LAYER 4, FORTIFIBER <br />BUILDING PAPER <br />FETAL LATH <br />WOOD l/S' TEXTURED <br />CONSTRICTION Y�PIEMBER NI • WOOD <br />ru <br />FASTEN TO WOOD STRUCTURAL <br />M. V O.C. MAX <br />8' cti <br />`V TO <br />)I' <br />Lj <br />'AT <br />6' WIDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYING <br />V — I-INIeH • MASONRY <br />HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK) <br />S' <br />HOUSEWRAP <br />B <br />WRLAYER h, <br />BELOW <br />STUCCO WRAP <br />CUT SUCH THAT <br />9 <br />APPLY 60 MIN <br />SELF -ADHERING <br />NO MEMBRANE <br />GRADE 'D' FELT <br />® <br />MEMBRANE FLASHING <br />ENTERS BOX, <br />_ <br />OVER <br />APPLY TO FAGS <br />SELF -ADHERING <br />EDGE <br />FLASHING OVER <br />APROVED <br />HOUSEWRAP <br />WRB LAYER R, FORTIP15ER <br />BUILDING PAPER <br />STEP 03 <br />STEP #4 <br />APPLY E-Z BEAD <br />OVER 60 MIN <br />GRADE 'D' <br />FELT -PROVIDE <br />SEALANT AT ALL <br />JOINTS AND <br />INTERSECTIONS <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ C.Y. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />AL LATH <br />STEP 05 STEP I'& <br />(9 l ELECTRICAL RECEPTACLE <br />R <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-7744078 <br />www.abdeslgngroup.com <br />` AA #: 0003325 <br />a <br />a <br />IT <br />EiVHDI\/. Ac LOT: <br />ABBOTT PARK <br />LOT #32 <br />BLK #11 <br />PROJECT# <br />04181.000-32112 <br />MODELt <br />4EHB <br />"2605—HAYDEN" <br />GARAGE Slr111WO: <br />RIGHT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />60 MPH EA V <br />9 <br />Da 04/19/21 <br />SCALE: 1/4"=1'-0" <br />SHEET <br />dd A2 <br />