Laserfiche WebLink
© TRIM NAIL <br />INSTALLED THROUGH <br />FASCIA @ 16" O.C. MAX <br />7O STAPLESINSTALLED <br />THRU SOFFIT AT NAIL <br />HEM AND IN VALLEYS <br />® FASCIA­'/J-CHP <br />}" MAX. <br />DETAIL A <br />FASCIA <br />O STAPLESINSTALLED <br />12" O.C. MAX (INTO <br />WOOD) IN J-CHANNEL <br />SLOT OR T-NAIL @ 12" <br />O.C. MAX. (INTO <br />CONCRETE/MASONRY) <br />FASCIA WOOD <br />BOARD BY OTHERS <br />70 STAPLESINSTALLED- <br />THRU SOFFIT AND <br />J-CHANNEL AT NAIL <br />HEM AND IN VALLEYS <br />STAPLESINSTALLED @—r_ <br />12" O.C. MAX (INTO <br />7QWOOD) IN J-CHANNEL <br />SLOT } <br />2X2 WOOD BATTEN 10 <br />STAPLES INSTALLED 70 <br />THRU SOFFIT AND <br />J-CHANNEL AT NAIL HEM <br />AND IN VALLEYS <br />#8X3" WOOD SCREW OR <br />TAPPING SCREW, <br />BATTEN ATTACHMENT <br />FASTENER SPACED 24" <br />MAX. O.C. <br />ELQ <br />}" MAX -ol I. — <br />DETAIL D O STAPLES INSTALLED, <br />J-CHANNEL THRU SOFFIT AND <br />CHANNEL AT NAIL <br />FASCIA HEM AND IN VALLEYS <br />O SOFFIT ----'I <br />Q J-CHANNEL-/ <br />J-liflFlIV1V CL <br />TRUSS/FRAMING OVERHANG EAVE CONSTRUCTION <br />BATTEN STRIP ANCHOR 12 <br />10d NAIL AT EACH <br />TRUSS/JOIST/ RAFTER <br />LOCATION NOT TO <br />EXCEED 24" O.C. INTO <br />FRAMING rTRUSS/JOI <br />/ BY OTHER <br />2-1/4" <br />EMB. <br />WOOD BATTEN <br />DETAIL B <br />J-ICI-IHIV IV C L <br />FASCIA <br />12 BATTEN STRIP ANCHOR <br />10d NAIL AT EACH <br />TRUSS/JOIST/ RAFTER <br />LOCATION NOT TO <br />EXCEED 24" O.C. INTO <br />7O STAPLESINSTALLED- <br />THRU SOFFIT AND <br />J-CHANNEL AT NAIL <br />HEM AND IN VALLEYS <br />O 11 1X2 WOOD BATTI <br />�2X2 WOOD BATTEN 10 <br />O S <br />INSTALLATION SCREW, <br />BATTEN ATTCHMENT <br />FASTENER SPACED 24" Og <br />MAX O.C. <br />STAPLESINSTALLED(t� <br />12" O.C. MAX (INTO <br />(D WOOD) IN J-CHANNEL <br />O SLOT OR T-NAIL @ 12" <br />O.C. MAX. (INTO <br />CONCRETE/MASONRY) <br />CONCRETE/CMU OR <br />WOOD (NOTE 1) <br />SPAN 'L' <br />SPAN 'L <br />EAVE WIDTH <br />EAVE WIDTH <br />(ROOF <br />(ROOF <br />OVERHANG) <br />OVERHANG) <br />j <br />CONCRETE; <br />CMU OR WOOD <br />(NOTEA) <br />CONCRETE; <br />OFFIT <br />CMU OR WOOD <br />IT <br />SEE DETAIL'A'SEE DETAIL'E' <br />SEE DETAIL'D'J SEE DETAIL'E' <br />(NOTE:1) <br />EAVE CROSS-SECTION <br />EAVE CROSS-SECTION <br />SINGLE SPAN WN-CHANNEL <br />SINGLE SPAN W/J-CHANNEL <br />J-CHANNEL @ WALL, FASCIA @ FASCIA END <br />J-CHANNEL @ WALL AND FASCIA END <br />Q J-CHANNEL <br />}" <br />DETAIL C <br />J-CHANNEL <br />/RAFTER <br />BY OTHER <br />2-1/4" INSTALLATION SCREW, <br />EMB. BATTEN ATTCHMENT <br />FASTENER SPACED 24" Og <br />MAX O.C. <br />STAPLESINSTALLED <br />12" O.C. MAX (INTO <br />7O WOOD) IN J-CHANNEL <br />O SLOT OR T-NAIL @ 12" <br />O.C. MAX. (INTO <br />CONCRETE/MASONRY) <br />CONCRETE/CMU OR <br />WOOD (NOTE 1) <br />NOTE 1: MINIMUM SPRUCE -PINE -FIR <br />FRAMING OR CONCRETE/MASONRY. <br />BUILING CODE REQUIREMENTS FOR <br />SUBSTRATE MATERIAL MUST BE MET. <br />Fg <br />i i 4 3.625 3.625 <br />5 <br />06 .0 <br />12�e <br />DETAIL A <br />12" TRIPLE 4 FULL-0-VENT SOFFIT ECO <br />VINYL -NO. 639 <br />1441 N. RONALD RFAGAN BLVD. <br />LONGWOOD, FL32750 <br />PH: 407-774-W78 <br />FAX: 407-774•1078 <br />www.abdasigngroup.com <br />AA #: 0003325 <br />34 <br />a <br />BVHDIV. 'k LOT <br />ABBOTT PARK <br />LOT #32 <br />BLK #11 <br />PROJECT# <br />04181.000-32112 <br />MODEL: <br />4EHB <br />"2605- HAYDEN" <br />GARAGE 1911FMG: <br />RIGHT <br />PARE: <br />SOFFIT <br />DETAILS <br />60 MPH EXP. <br />scALE: 1/4"=1'-0" <br />