Laserfiche WebLink
INSTALL 6' SELF -ADHERING <br />MEMBRANE FLASHING OVER <br />TOP, SIDES) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SEQUENCE OF FLASWMG TO BE, <br />I. BOTTOM, 2. SIDES. 9. TOP <br />VENT CAP IS TO BE SET IN BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT IS TO BE <br />TOOLED SO AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />�X <br />E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />JOINTS AND INTERSECTIONS <br />r <br />� <br />APPLY SEALANT AT PERIMETER OF <br />BACKER ROD <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDES, A' CAULKING • JOINT <br />ALL AROUND <br />I I <br />PER SECTION <br />Etdedor 1et111na andohoWna <br />BACKER ROD <br />Exterior use of portland cement plaster <br />shall comply with the application <br />JG. <br />requirements of ASTM C 928-18b. <br />Installation of exterior lathing and framing <br />1 <br />shall comply with ASTM C 1083-19a, <br />:X. <br />or ASTM 1787. <br />WRB LAYER'!, <br />��...X: <br />STUCCO WRAP <br />HOODED VENT <br />i' THICK, 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />WIRE, LAYER 9, FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />© DRYER <br />VENT ( FRAME) <br />WOOD SHEATHING <br />LAYER'!, <br />87UCC0 WRAP <br />LAYER R, FORT[FIBER <br />BUILDING PAPER <br />TION <br />4�111111111 <br />METAL LATH <br />eVINYL CASING BEAD <br />6' RAISED BIND <br />V TO K' M 12-WALL <br />nsw� wrr� <br />64 <br />V WIDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYING <br />Z FLASHING <br />STONE VENEER <br />OVER SCRATCH COAT <br />HORIZONTAL WEEP SCREED <br />W/STONE VENEER <br />(FRAME TO BLOCK) <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER *2 (FORTIFIBER — — — — — <br />BUILDING PAPER) <br />METAL LATH x—x—X—x <br />STUCCO <br />WOOD OR '1/16" ZIP WALL <br />SHEATHING <br />SELF-ADHESIVE FLASHING — — — — — <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R103.1.1 / ASTM C-841-14a, MIN. 2.5 LBS. <br />PER 90. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />FLASHING <br />UNIT <br />PREMANUF. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT • <br />TOP 4 SIDES <br />F B DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' <br />PIPE THROUGH / <br />WALL <br />1 <br />6' SELF ADHESIVE — <br />FLASHING !INSTALL <br />PER MANUF. SPECS.) <br />BUILDING PAPEI <br />UNDER 'QUICK FLAB! <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />A VENT PENETRATION <br />SCALE: N.T.B. <br />I <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />CONSTRUCTION <br />WOOD SHEATHING <br />WRB LAYER PI, <br />STUCCO WRAP <br />WRB LAYER 02, FORTIF15ER <br />BUILDING PAPER <br />9' THICK, 3 COAT CEMENT <br />PLASTER <br />Ye' TO V MID -WALL <br />WEEP SCREED <br />6' SELF-ADHESIVE <br />FLASHING <br />WOOD FRAMED <br />_,_ " t °' WALL <br />HORIZONTAL WEEP SCREED <br />( FRAME TO FRAME) <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />-('GREAT STUFF' OR SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />AREA TO RECEIVE — <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION PROVIDE STUCCO SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LAYER 01, <br />STUCCO WRAP <br />WOOD SHEATHIA <br />HOUSEWRAP <br />BELOW <br />CUT SUCH THAT <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY TO FACE <br />EDGE <br />APPLY E-Z BEAD <br />OVER 60 MIN <br />GRADE D. <br />FELT -PROVIDE <br />SEALANT AT ALL <br />JOINTS AND <br />INTERSECTIONS <br />WOOD SHEATHING <br />WRS LAYER h, <br />STUCCO WRAP <br />WRIS LAYER -2, FORTIFIBER <br />BUILDING PAPER <br />METAL LATH <br />FASTEN TO WOOD STRUCTURAL <br />MEMBER • T' OC. MAX <br />K' TO)P MID -WALL <br />weer acleeeD <br />6' WIDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYING <br />V FIN16H • MASONRY <br />(�4 HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK) <br />STEP #1 <br />STEP #3 <br />a' <br />WRB LAYER M, <br />STUCCO WRAP <br />.... ......... ...... WM LAYER 01, <br />STUCCO WRAP <br />9 APPLY 60 M <br />SEMBRANE <br />T <br />GRADE 'D' FELT <br />FLA <br />MEMERANE FLASHING <br />OVER <br />SELF -ADHERING <br />FLASHING OVER <br />APROVED <br />HOUSEWRAP <br />WRB LAYER 42, FORTIFIBER <br />SUILDING PAPER <br />STEP #4 <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ C.V. FINISH <br />(SEE TYPICAL W LL <br />SECTION) <br />METAL LATH <br />STEW 05 STEP #ro <br />OELECTRICAL RECEPTACLE <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407.7745078 <br />FAX: 407.7744078 <br />www.abdeslgngroup.com <br />AA 8: 0003325 <br />h <br />q <br />o <br />3 <br />SVHDIV. Ce IAT: <br />ABBOTT PARK <br />LOT #32 <br />BLK #11 <br />PROJECT# <br />04181.000-32113 <br />MODRILA <br />4EHB <br />"2605-HAYDEN" <br />GARAGE SIIITTG: <br />RIGHT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />60 MPH EXP. <br />SEM 3 <br />SCALE: 1 /4"=1' — 0" <br />aII CZT <br />WA2 <br />