My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7657 Sail Clover Ln
Zephyrhills
>
Building Department
>
Building Plans
>
7657 Sail Clover Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 6:59:20 PM
Creation date
2/24/2025 9:37:14 AM
Metadata
Fields
Template:
Building Plans
Street #
7657
Location
Sail Clover Ln
Contractor
D R Horton
Building Plans - Permit #
3306
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INSTALL S' SELF -ADHERING <br />MEMBRANE FLASHING OVER <br />TOP, SIDE(S) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SEOIJENCE OF FLASHING TO BE. <br />I. BOTTOM. 2. SIDES, 3. TOP <br />X: <br />VENT CAP IS TO BE SET IN BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT IS TO BE <br />TOOLED SO AS TO DEFLECT <br />" <br />WATER AWAY FROM JOINTS. <br />X. <br />E-Z DEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />�t <br />JOINTS AND INTERSECTIONS <br />APPLY SEALANT AT PERIMETER OF <br />BACKER ROD <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDES.Yi CAULKING • JOINT <br />ALL AROUND, <br />I <br />PER SECTION <br />bderlor leNng and rig <br />BACKER ROD <br />I I <br />Exterior use of Portland cement plaster <br />shall comply with the application <br />requirements of ASTM C 926-18b. <br />X". <br />k: <br />Installation of exterior lathing and framing <br />I <br />shall comply with ASTM C 108319a, <br />or ASTM 1787. <br />WRB LAYER 'I, <br />�,..X. <br />STUCCO WRAP <br />HOODED VENT <br />THICK, 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />WRB LAYER -2, FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER VENT <br />(FRAME) <br />ra <br />SHEATHING <br />RTIFIBER <br />ING PAPER <br />waoD <br />coNsnJCTION <br />—METAL LATH <br />a• CMu VINYL CA81NG BEAD <br />6' RAISED ISAND <br />V TO Ji' MID -WALL <br />WEEP eGRE[D <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYW. <br />Z FLASHING <br />STONE VENEER <br />OVER SCRATCH COAT <br />HORIZONTAL WEEP SCREED <br />W/STONE VENEER <br />(FRAME TO BLOCK <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER e1, STUCCO WRAP) <br />WRB LAYER 02 (FORTIFIBER — — — — — <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />WOOD OR '1/16" ZIP WALL <br />SHEATHING <br />SELF-ADHESIVE FLASHING — — — — — <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R103.1.1 / ASTM C-841-14a, MIN. 2.5 LBS. <br />PER SQ. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />FLASHING <br />UNIT <br />PREMANUR DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT • <br />TOP 4 SIDES <br />F)B DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' <br />PIPE THROUGH / <br />WALL <br />1 <br />6' SELF ADHESIVE — <br />FLASHING (INSTALL <br />PER MANUF. SPECS.) <br />BUILDING PARR <br />UNDER 'QUICK FLASH' <br />ELEC. METE? <br />VERIFY LO <br />CONSTRUCTION <br />WOOD SHEATHING <br />WRB LAYER 01, <br />STUCCO WRAP <br />WRB LAYER W2, FORTIFIBER <br />BUILDING PAPER <br />9' THICK, 3 COAT CEMENT <br />PLASTER <br />Ye' TO V MID -WALL <br />WEEP SCREED <br />WOOD � <br />. CONSTRUCTION <br />6' SELF-ADHESIVE <br />FLASHING a cru <br />WOOD FRAMED <br />f — — — —I WALL <br />HORIZONTAL WEEP SCREED _. <br />( FRAME TO FRAME) <br />A VENT PENETRATION <br />SCALE: N.T.S. <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />I <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING: ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />-('GREAT STUFF' OR SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />PROVIDE STUCCO SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />WOOD SHEATHING <br />WRB LAYER M, <br />STUCCO WRAP <br />WRB LAYER -2, FORTIFIBER <br />BUILDING PAPER <br />METAL LATH <br />FASTEN TO WOOD STRUCTURAL <br />MEHWR • T' OC. MAX <br />fi"' TOY,' MID -WALL <br />nir�o arsawn <br />6' WIDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYING <br />(�oHORIZONTAL WEEP SCREED <br />FRAME TO BLOCKI <br />8' <br />UJRB LAYER $1, <br />CUT OPENING IN <br />STUCCO WRAP <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />CUT 'X' INTO <br />WRB LAYER 01, <br />SELF -ADHERING <br />�1 <br />STUCCO WRAP <br />MEMBRANE FLASHING <br />L:A <br />APPLY SELF -ADHERING <br />WOOD SHEATHING <br />MEMBRANE FLASHING <br />z <br />OVER BOX AND OVER <br />APPROVED UJRB <br />LAYER '1 <br />STEP #1 <br />STEP <br />4*2 <br />APPROVED <br />HOUSEWRAP <br />WRB LAYER M, <br />BELOW <br />STUCCO WRAP <br />CUT SUCH THAT <br />0 <br />APPLY 60 MIN <br />SELF -ADHERING <br />NO MEMBRANE <br />GRADE 'D' FELT <br />® <br />MEMBRANE FLASHING <br />ENTERS BOX, <br />_ <br />OVER <br />APPLY TO FACE <br />SELF -ADHERING <br />EDGE <br />FLASHING OVER <br />AP IROVED <br />HOUSEWRAP <br />UMB LAYER 02, FORTIF115ER <br />BUILDING PAPER <br />STEP 03 <br />STEP <br />#4 <br />APPLY £-Z BEAD <br />OVER 60 MIN <br />GRADE 'D' <br />FELT -PROVIDE <br />SEALANT AT ALL <br />JOINTS AND <br />INTERSECTIONS <br />1441 N. RONALD REAGAN 8LVD. <br />LONGWOOD, FL32780 <br />PH: 407-7746078 <br />FAX: 407-774-4078 <br />www.abdesigngmup.aom <br />AA #: 0003325 <br />i <br />rr <br />S <br />o <br />avISDIV. Ae MM7 <br />ABBOTT PARK <br />LOT #43 <br />BLK. #7 <br />PROMWT# <br />041 1.000-43071 <br />MODTSEA <br />4EBB <br />"1828-CALI" <br />GAMAGM aMxo: <br />RIGHT <br />PADS: <br />WALL <br />ASSEMBLY <br />DETAILS <br />160 MPH EXP. C <br />ELASTOMERIG AF <br />COATING OVER <br />STUCCO/ C.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />METAL LATH <br />STEP #S STEP #6 <br />(9) ELECTRICAL RECEPTACLE <br />%% M No_j <br />DATA 9/21/21 <br />SCALE: 1/4"=1'-0" <br />SHETH <br />E�TT <br />dY ^ <br />2 <br />