"A" <br />V1]S�9C9 <br />> HIP ROOF <br />ROOF WIND DESIGN PRESSURES <br />NET IGFO9S) ASCE I-1B <br />ZME1 -I84 ZONES " 5.8 <br />I-E3e_1.1 _S_. <br />"E I <br />A� PO" ENO ZON£ DSTANCE <br />BA91C WINDISPEED 1W MPH <br />RI%PoSl1RE�U�Ty fOC6V:'C <br />EINTERNAL <br />PRESSURE_1F ENT:­18 <br />ROOF DIAPHRAGM <br />FOR ASPHALT SHINGLE ROOF, USE MIN 7/16" STRUCTURAL <br />SHEATHING EXP 1(24/16) or 15/32" STRUCTURAL SHEATHING EXP 1 <br />(32116). FOR CEMENTITIOUS TILE AND METAL ROOFING, USE 15/37- <br />STRUCTURAL SHEATHING EXP 1 (32/16) .(SEE TABLE FOR FIELD AND <br />EDGE SPACING) SEE DETAIL. <br />ROOF SHEATHING TO GABLE END FRAME USE 8d RING SHANK GUN <br />NAILS @ 4" O.C. EDGEWISE 2x4 BLOCKING ALL PANEL JOINTS W/ IN 4' <br />OF GABLE END. <br />ROOF/ WALL/ FLOOR <br />SHEATHING <br />FASTENER SCHEDULE <br />NAIL REQUIREMENTS <br />SIZE <br />HEAD <br />LENGTH <br />DIA <br />TENSILE STR. <br />SHANK <br />ASTM <br />Btl <br />RING SHANK, <br />23/8" <br />0.113 <br />17p,p00 <br />RING <br />RINGS <br />F <br />SCREW SHANK <br />(16-20 <br />PER INCH <br />RSRSSRS-01 <br />8d <br />RING SHANK, <br />PNEUMATIC <br />23/8" <br />0.113 <br />I <br />F1667 <br />SCREW -NAILS <br />RSRS-01 <br />EXTERIOR SHEATHING <br />USE 1/2" COX OR 7/16' O.S.B. PLY WITH Ed RING SHANK GUN NAILS AT <br />4" O.C. AT PANEL SIDES AND 8d RING SHANK GUN NAILS 4" O.C. TOP & <br />BOTTOM PANEL AND 8d RING SHANK GUN NAILS AT 6' O.C. AT <br />INTERMEDIATE SUPPORTS OR 7116" ZIP SHEATHING SYSTEM <br />(INSTALLED PER MANUF, SPECS.) SEE DETAIL. <br />ROOF SHEATHING ATTAID EMENT SPACING <br />ZONE 1: 8d NAILS (� 4" O.C. ON EDGE AND 6' O.C. IN FIELD <br />ZONE 2e, 2n, 2T: 8d NAILS C 4" O.C. ON EDGE AND 4" O.C. IN FIELD <br />ZONE 3,3e, 3, 8d NAILS @ 4" O.C. ON EDGE AND 4" O.C. IN FIELD <br />NOTE ROOF SHEATHING THICKNESS WAS CALCULATED <br />AND ADHERES TO ASCE 7-16 <br />z <br />zQ <br />zo <br />W <br />Y0 <br />Q U, <br />NO <br />fY <br />E <br />8d RING SHANK GUN NAILS f@ 4" O.C. <br />TOP & BOTTOM EDGES <br />N <br />li <br />N TYP.EXT.SHEATHING ATTACHMENT <br />0 <br />zw <br />w <br />2 <br />C=DW <br />Z� <br />T U <br />Tn b <br />2 `v <br />0 <br />EMMM,-I 11 <br />2 N <br />o O <br />m <br />^� BUILDING LENGTH <br />ROOF SHEATHING LAYOUT <br />AND ENDWALL BRACING <br />FOR GABLE END FRAMING <br />NOTE: GABLES -DROP GABLE END & (1) ADD'L DROPPED <br />TRUSS 2x4 #2 SYP OUTLOOKER RAFTER W/ BLOCKING 0 <br />16'0.C. IF NO DROPPED GABLE END, ATTACH 214 #2 SYP <br />BLOCKING 0 16' O.C. FIRST 4 BAYS W/ (2)12d NAILS EA. <br />END. ATTACH ROOF SHEATHING TO RAFTERS 2/ <br />BLOCKING PER NAILING SCHEDULE <br />8d RING SHANK GUN NAILS <br />SEE "ROOF SHEATHING ATTACHMENT' <br />TABLE FOR FIELD SPACING \ <br />`#8 2" DECK SCREWS 0 6"-8" O.C. MAX <br />EDGES 8, 12- O.C. MAX IN FIELD. UNTHREADED <br />SHANK TO EXTEND BEYOND THICKNESS OF <br />SUB -FLOOR SHEATHING ` <br />TYP. 3/4" T&G SUB -FLOOR DECKING GLUED TO ALL EXPOSED MEMBERS <br />GENERAL NOTES: <br />STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOB SPECIFICATIONS AND <br />ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND SITE DRAWINGS. CONSULT <br />ARCHITECTURAL DRAWINGS FOR SLEEVES, DEPRESSIONS, AND OTHER DETAILS NOT SHOWN <br />ON STRUCTURAL DRAWINGS. APPLICABLE BUILDING CODE STANDARDS: FBC-R 2020, 7th EDITION <br />ACI 318-14, BUILDING CODE REQUIREMENTS <br />FOR STRUCTURAL CONCRETE, TMS 4021602-16 AISI SPECIFICATION FOR THE DESIGN OF <br />COLD -FORMED STEEL STRUCTURAL MEMBERS 2016, ASCE 7-16 AND AISC SPECIFICATIONS <br />ALL DETAILS AND SECTIONS SHOW ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND <br />SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE ON THE PROJECT, <br />EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN. <br />ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD. DO NOT SCALE THE <br />DRAWINGS. FOLLOW WRITTEN DIMENSIONS ONLY. ANY DISCREPANCIES SHALL BE BROUGHT <br />TO THE ATTENTION OF THE ENGINEER PRIOR TO PROCEEDING WITH THE AFFECTED PART <br />OF THE WORK. <br />THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND STABLE AFTER THE BUILDING <br />IS COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES AND <br />SEQUENCES TO INSURE SAFETY OF THE BUILDING AND ITS COMPONENTS <br />DURING ERECTION. THIS WORK INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING, <br />TEMPORARY BRACING, GUYS OR TIE-0OVVNS. <br />THE CONTRACTOR SHALL SUPPLEMENT THE MINIMUM REQUIRED FOUNDATION AND SITE PREPARATION <br />REQUIREMENTS AND SLAB-OWGRADE THICKNESS TO HANDLE CONSTRUCTION LOADS. <br />ALL AGGREGATE USED IN CONCRETE SHALL CONFORM TO ASTM <br />PROVIDE 8%AIR ENTRAINED CONCRETE EXPOSED TO EARTH OR <br />ALL EXPOSED EDGES OF CONCRETE ARE TO BE CHAMFERED 314'. <br />PROVIDE S-MIL CONTINUOUS POLYETHYLENE VAPOR BARRIER MEMBRANE UNDER ALL SLASS.ON-GROUND WHERE INDICATED ON <br />DRAWINGS. SEAMS LAPPED S INCHES AND SEALED WITH ADHESIVE TAPE. <br />FORM WORK: <br />FORM -WORK, SHORING, AND BRACING FOR ALL CONCRETE BEAMS, SLABS, COLUMNS, WALLS, <br />AND FOOTINGS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH ACI 347 LATEST <br />EDITION, 'RECOMMENDED PRACTICE FOR CONCRETE FORM -WORK. <br />EXCLUSIONS FROM THESE PLANS" <br />WOOD: <br />ALL WOOD FOR BEAMS, BEARING WALLS, SOLE PLATES, TOP PLATES, BRACING, LEDGERS, BLOCKING, <br />CRIPPLERS, SILLS, ETC., SHALL BE SOUTHERN PINE NO, 2 OR BETTER. Fb - 1100 PSI AND A MODULUS OF <br />ELASTICITY = 1,400,000 PSI. ALL WOOD IN CONTACT WITH CONCRETE OR CONCRETE BLOCK SHALL BE <br />PRESSURE TREATED. WOOD FOR NON-STRUCTURAL USES SHALL BE RATED TO RETENTION LEVELS OF 0,25 <br />PCF OF A BORATE PRESERVATIVE TREATMENT: DISODIUM CORROBORATE TETRAHEDRAL (DOT). WOOD FOR <br />STRUCTURAL USE THAT SHALL BE TREATED FOR ANY REASON SHALL BERATED TO RETENTION LEVELS OF <br />0.42 PCF FOR DOT OR MORE. NAILS, SPIKE, BOLTS USED W/ DOT SHALL BE HOT DIPPED GALV. FOR <br />STRUCTURAL USES, AVOID BUYING TREATED LUMBER THAT CONTAINS MORE THAN W OF HEARTWOOD. <br />MINIMUM NAILING PER FBCR 2020.7th EDITION. SEE NAILING SCHEDULE ON PLANS <br />PROVIDE SOLID BLOCKING UNDER ALL POINT LOADS AND WOOD COLUMNS WITH 2x STRUCTURAL LUMBER <br />SYP #2. <br />WATERPROOFING, FLASHING, SOUND ISOLATION, FIRE SEPARATION, OR OTHER NON STRUCTURAL ITEMS <br />MEETING THE RE UIREMENTS OF ASTM A446/A446M GRADE A AND SHALL BE HOT DIPPED GALVANIZ D <br />ARE NOT PART OF THE STRUCTURAL PLANS AS THEY ARE NOT CONSIDERED TO BE STRUCTURAL.DEPENCING UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WITH CONCRETE. SEAT PLATES SHALL BE PROVIDED <br />ON THE TYPE OF CONSTRUCTION THESE ITEMS SOME OR ALL MAY BE REQUIRED BUT ARE BY OTHERS. <br />AT BEARING LOCATIONS WITHOUT WOODEN TOP PLATES. <br />WOOD TRUSSES: <br />WELDED WIRE MESH: <br />TO BE DESIGNED AND FABRICATED IN ACCORDANCE WITH THE NATIONAL DESIGN SPECIFICATIONS FOR <br />WELDED WIRE MESH, SHALL BE ASTM A1064/1064M, GRADE 65, FREE FROM OIL, SCALE, AND RUST, AND BE <br />STRESS -GRADE LUMBER AND ITS FASTENINGS' BY THE NFPA. TRUSS DESIGNS SHALL BE SIGNED AND <br />PLACED IN ACCORDANCE WITH THE ACI TYPICAL DETAILS. MINIMUM LAP SHALL BE ONE SPACE PLUS TWO <br />SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN FLORIDA. SEE NOTED FOR SHOP DRAWINGS. <br />INCHES. WIRE MESH FOR SLABS SHALL BE SUPPORTED WITH 2° CHAIRS SPACED 3'-0" OC, EACH WAY. <br />CONNECTOR PLATES SHALL BE A MINIMUM THICKNESS OF 0.038' AND BE MANUFACTURED FROM STEEL <br />DO NOT SCALE DRAWINGS. THE CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR <br />REINFORCING STEEL: <br />0 E <br />DESIGN, FABRICATE, AND ERECT WOOD TRUSSES IN ACCORDANCE WITH TPI-14, "DESIGN NATIONAL <br />TO WORK PERFORMED AND SHALL NOTIFY THE ENGINEER IF ANY DISCREPANCIES ARE FOUND. <br />REBAR SHALL BE ASTM A615/815M GRADE 60 DEFORMED BARS, FREE FROM OIL, SCALE, AND RUST AND <br />STANDARDS FOR METAL -PLATE -CONNECTED -WOOD TRUSS CONSTRUCTION:, AND "SCSI LATEST EDITION" <br />PLACED IN ACCORDANCE VN/ THE TYPICAL BENDING DIAGRAM AND PLACING DETAILS OF THE ACI STANDARDS <br />COMMENTARY AND RECOMMENDATIONS FOR HANDLING, INSTALLATION BRACING METAL -PLATE -CONNECTED <br />DESIGN LOADS: <br />AND SPECIFICATIONS. CONTRACTOR SHALL SUBMIT REBAR SHOP DRAWINGS FOR REVIEW PRIOR TO <br />WOOD TRUSSES. <br />FABRICATION. HORIZONTAL AND VERTICAL BARS SHALL LAP 6 x BAR NO. UNSCHEDULED FIELD LAPS ARE <br />ROOF: LIVE LOAD FLOOR' <br />LIVE LOAD 40 pef <br />SUBJECT TO ENGINEER'S REVIEW. <br />TRUSS MANUFACTURER WILL PROVIDE CALCULATIONS INDICATING ADDITIONAL DEAD LOADS FOR THE ROOF <br />20 pef TOP CHORD+to0c rtent <br />TYP. MIN LAPS SHALL BE AS FOLLOWS: #4 BAR 25" #6 BAR - - 36" <br />LOCATIONS WITH GUSSETS, CRICKETS AND VALLEY LOCATIONS REQUIRING ADDITIONAL ROOF FRAMING FOR <br />10 psf BTM CHORD-nonconcunant <br />#5 BAR - 30' #7 BAR - 47' <br />INTERSECTIONS OF HIGHER OR LOWER ROOFS IN ACCORDANCE WITH ANSIIA3CE 7 88: 1990. <br />2001b CONCENTRATED LOAD ALL BTM CHORD PANEL JOINTS (HVHZ <br />ONLY)Hlon-DonourteM <br />PROVIDE 36',, 38' CORNER BARS, BOND BEAM ONLY, LAPPED AND TIED TO EACH BEAM REBAR, SEE DETAILS <br />FOR ADDITIONAL INFORMATION. <br />HURRICANE STRAPS SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTRUCTIONS. <br />DEAD LOAD <br />DEAD LOAD <br />15 psf TOP CHORD <br />20 psf TOP CHORD <br />ALL VERTICAL REINFORCING BARS IN CMU CELLS SHALL BE ANCHORED IN THE FOOTING, <br />CONTRACTOR SHALL SUBMIT SIGNED AND SEALED DRAWINGS FOR ALTERNATE CONNECTION DETAILS AT <br />(10 psf w/ ASPHALT SHINGLES) <br />(10 paf W/ No GYPCRETE) <br />THICKENED SLAB, BEAM OR LINTEL SUPPORTING THE WALL AT THE TOP AND BOTTOM WITH <br />TRUSSES/GIRDERS TO COLUMNS AND WALLS FOR APPROVAL. <br />10 paf BTM CHORD <br />5 psf BTM CHORD <br />MINIMUM 101NCH HOOKS OR BENDS AND SHALL BE CONTINUOUS THROUGHOUT THE HEIGHT OF THE <br />DEAD LOAD TO RESIST WIND UPLIFT: 1 OW <br />WALL. <br />ROOF & FLOOR LAYOUTS PROVIDED ON THESE PLANS ARE TO BE USED AS A GUIDE FOR BEARING <br />BALCONY LIVE LOAD 60 pet <br />DETERMINATIONS, FEASIBILITY & ARCHITECTURAL AIDE. TRUSS MANUFACTURER IS RESPONSIBLE FOR FINAL <br />WIND: DEAD LOAD SPEED=160 MPH 3-SECOND GUST <br />(ASCE 7A6 (FBC R2020) EXPOSURE C, RISK CATEGORY II) <br />LIVE LOADS: UNINHABITABLE ATTIC WITHOUT STORAGE: 10psf, UNINHABITABLE ATTIC WITH LIMITED <br />STORAGE: 20pef, HABITABLE ATTICS AND ATTICS SERVED WITH FIXED STAIRS: 30psf, BALCONIES (EXTERIOR) <br />AND DECKS: 40psf, GUARDS AND HANDRAILS: 200psf, GUARD IN -FILL COMPONENTS: 50pd,, PASSENGER <br />VEHICLE GARAGES: 50psf, ROOMS OTHER THAN SLEEPING ROOM: 40psf, SLEEPING ROOMS: 30psf, STAIRS: <br />40psf <br />SHOP DRAWINGS WILL BE REVIEWED FOR GENERAL COMPLIANCE WITH THE DESIGNING INTENT <br />OF THE CONTRACT DOCUMENTS ONLY. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY <br />COMPLIANCE WITH THE CONTRACT DOCUMENTS AS TO QUANTITY, LENGTH, ELEVATIONS, DIMENSIONS, ETC <br />ALL SHOP DRAWINGS SHALL BE REVIEWED BY THE CONTRACTORS PRIOR TO SUBMITTAL TO THE ENGINEER <br />DRAWINGS SUBMITTED WITHOUT REVIEW WILL BE RETURNED UNCHECKED. SHOP DRAWINGS IN THE FORM <br />OF REPRODUCIBLE SEPIAS OF STRUCTURAL DRAWINGS (CON -TRACT DOCUMENTS) ARE PROHIBITED <br />WITHOUT THE EXPRESS WRITTEN PERMISSION FROM THE ENGINEER. IN ALL INSTANCES, THE CONTRACT <br />DOCUMENTS WILL GOVERN OVER THE SHOP DRAWINGS CHECKED UNLESS OTHERWISE SPECIFIED IN <br />WRITING BY THE ENGINEER. <br />FOUNDATION/ SITE PREPARATION: <br />FOOTINGS VVERE DESIGNED FOR AN ALLOWABLE SOIL BEARING PRESSURE OF 2,000 pcf, <br />FOOTING EXCAVATIONS AND SLAB SUB -GRADE SHALL BE COMPACTED TO A DRY DENSITY <br />OF AT LEAST 95% OF THE MODIFIED PROCTOR MAXIMUM DRY DENSITY DETERMINED IN <br />ACCORDANCE WITH ASTM D-1557. TREAT ALL SOIL FOR TERMITE PROTECTION. <br />THE OWNER SHALL RETAIN THE SERVICES OF AN INDEPENDENT GEO-TECHNICAL ENGINEER TO VERIFY <br />SUCCESSFUL COMPLETION OF SITE PREPARATION EFFORTS. LOCATIONS FAILING TO MEET THE <br />GEO-TECHNICAL ENGINEER'S REQUIREMENTS SHALL BE RE -COMPACTED AND RETESTED AT THE <br />CONTRACTOR'S EXPENSE, AND AS DIRECTED BY THE ENGINEER. WRITTEN CERTIFICATION THAT THE <br />MINIMUM DESIGN BEARING CAPACITY, AND THAT THE COMPACTION REQUIREMENTS HAVE BEEN MET SHALL <br />BE MADE BY THE GEO-TECH. ENGINEER. IF BUILDING PAD AREA TESTING RESULTS IN SOIL BEARING <br />CAPACITY THAT IS LESS THAN THE DESIGN BEARING CAPACITY, IT IS THE RESPONSIBILITY OF THE BUILDER <br />TO NOTIFY THE ENGINEER OF RECORD (VIA WRITTEN R.F 1.) SO THAT THE FOUNDATION CAN BE MODIFIED <br />ACCORDINGLY PRIOR TO START OF CONSTRUCTION. ENGINEER SHALL TAKE NO RESPONSIBILITY FOR <br />NEGLIGENCE BY BUILDER IN THIS ASPECT OF CONSTRUCTION. <br />CONCRETE: <br />CONCRETE SHALL ACHIEVE MINIMUM 28 DAY COMPRESSIVE STRENGTHS AS FOLLOWS: <br />RUN REINFORCING BARS CONTINUOUSLY LAPPED AT SPLICES AND AROUND CORNERS, DOWEL LAYOUT, SPANS & ALL TRUSS/ HEADER ENGINEERING, ANY DISCREPANCIES FROM THESE LAYOUTS THAT <br />INTO INTERSECTING WALLS AND HOOK AT ENDS. STAGGER SPLICES WHEREVER POSSIBLE. AFFECT THE STRUCTURAL BEARING AS CALLED OUT ON THESE. PLANS SHALL BE NOTIFIED TO THE <br />STRUCTURAL ENGINEER OF RECORD PRIOR TO MANUFACTURE OF TRUSSES. THE TRUSS FABRICATOR SHALL <br />DO NOT CUT OR DISPLACE REINFORCING STEEL TO ACCOMMODATE THE INSTALLATION OF EMBEDDED ITEMS PROVIDE ENGINEERED SHOP DRAWINGS OF EACH INDIVIDUAL TRUSS AND A FULLY DIMENSIONED ERECTION <br />WITHOUT THE APPROVAL OF THE ENGINEER. PLAN SHOWING COMPONENT LAYOUT. SHOP DRAWINGS SHALL BE SIGNED AND SEALED BY A FLORIDA <br />LICENSED PROFESSIONAL ENGINEER. <br />MASONRY: <br />MASONRY CONSTRUCTION AND MATERIALS SHALL CONFORM WITH ALL REQUIREMENTS OF THE <br />"SPECIFICATION MASONRY STRUCTURES" (TMS 402, BUILDING CODE REQUIREMENTS FOR MASONRY <br />STRUCTURES AND SPECIFICATIONS FOR MASONRY STRUCTURES AND COMMENTARIES), AS PUBLISHED BY <br />THE MASONRY STANDARDS JOINT COMMITTEE. <br />MASONRY WALLS SHALL BE LAID IN A RUNNING BOND PATTERN. PROVIDE 9 GA. LADDER TYPE HORIZONTAL <br />JOINT REINFORCING AT 16" O.C. TYP. (VERIFY WIDTH PER PLAN) <br />ALL BLOCK WALLS SHALL BE TWO -CELL HOLLOW CONCRETE MASONRY REGULAR SIZE BLOCK <br />MANUFACTURED IN CONFORMANCE WITH ASTM C-90, GRADE fm = 2000 PSI. BLOCK SHALL BE PLACED USING <br />RUNNING BOND UNLESS OTHERWISE NOTED. LAY-UP MASONRY WALLS TO BOTTOM OF TIE BEAMS BEFORE <br />PLACING CONCRETE FOR IWWALL COLUMNS. GROUT USED TO FILL MASONRY CELLS SHALL COMPLY WITH <br />ASTM C-476, AND SHALL PROVIDE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS, UNLESS <br />SPECIFICALLY NOTED OTHERWISE ON FOUNDATION PLAN. THE GROUT MIX SHALL HAVE A MAXIMUM 3/8" <br />COURSE AGGREGATE AND SHALL BE PLACED W/ A SLUMP OF T TO 10'. USE ONLY MECHANICAL VIBRATION <br />TO CONSOLIDATE GROUT. <br />THE HURRICANE STRAPS SPECIFIED ON THE WALL SECTIONS AND PLANS ARE PROVIDED TO FACILITATE THE <br />CONSTRUCTION SCHEDULE, AND MAY CHANGE PREDICATED ON THE TRUSS AND GIRDER REACTIONS <br />PROVIDED BY THE TRUSS ENGINEER. <br />THE TRUSS TO STRUCTURE CONNECTIONS AND LOADS SPECIFIED ON THIS PLAN SHALL SUPERCEDE THOSE <br />OF THE DELEGATED TRUSS ENGINEER. WIND UPLIFT VALUES HAVE BEEN BASED ON ASCE 7-16 COMPONENT <br />AND CLADDING WIND LOAD PRESSURES, THE DELEGATED TRUSS ENGINEER SHALL BE RESPONSIBLE FOR <br />ALL TRUSS TO TRUSS CONNECTIONS. <br />ALL SHEET METAL FRAMING CONNECTORS SHOWN ON THE PLANS SHALL BE "SIMPSON' STRONG -TIE <br />BY SIMPSON CO., OR EQUAL UNLESS NOTED OTHERWISE ON PLANS, INSTALL CONNECTIONS WITH <br />THE SIZE AND NUMBER OF BOLTSINAILS AS RECOMMENDED BY THE MANUFACTURER IN THE LATEST <br />CATALOG. <br />CONSTRUCTION OBSERVATION <br />CONSTRUCTION OBSERVATION SERVICES / CONSTRUCTION ADMINISTRATION SERVICES ARE NOT A PART OF <br />FLORIDA HORIZON ENGINEERING'S / AS DESIGN GROUP'S SERVICES FOR THIS PROJECT. <br />TYPE "M" OR "S" MORTAR SHALL BE USED EXCLUSIVELY ON THIS PROJECT. MORTAR SHALL BE IT I UNDERSTOOD AN AGREED THAT ORIZON ENGINEERING'S/AB DESIGN GROUP'S SCOPE OF <br />S D FLORIDAA <br />PROPORTIONED AND MIXED AS OUTLINED UNDER ASTM C-270. HORIZONTAL AND VERTICAL MORTAR JOINTS SERVICES DOES NOT INCLUDE PROJECT OBSERVATION ORR VIEW OF THE BUILDER'S / CONTRACTOR'S <br />SHALL BE 3/8" THICK UNLESS OTHERWISE NOTED. REMOVE MORTAR PROTRUSIONS THAT EXTEND INTO PERFORMANCE OR ANY OTHER CONSTRUCTION PHASE SERVICES AND THAT SUCH SERVICES WILL BE <br />CELLS TO BE FILLED. ALLOW A MINIMUM OF 72 HOURS FOR MORTAR TO CURE PRIOR TO GROUTING CELLS. PROVIDED BY THE BUILDER. THE BUILDER ASSUMES ALL RESPONSIBILITY FOR INTERPRETATION OF THE <br />CONTRACT DOCUMENTS, AND FOR CONSTRUCTION OBSERVATION. <br />FILL CMU CELLS SOLID WITH GROUT AT ALL CELLS TO RECEIVE EXPANSION ANCHORS AND/OR VERTICAL <br />REINFORCING. <br />LAP VERTICAL REBAR 6 X BAR NO. (48 BAR DIAMETERS)., U.N.O. <br />MASONRY CONSTRUCTION SHALL BE PERFORMED UNDER THE DIRECT SUPERVISION OF A "CERTIFIED <br />STRUCTURAL MASONRY CONTRACTOR". THE SUPERVISOR OF THE MASONRY PORTION OF THE PROJECT <br />SHALL BE A "CERTIFIED STRUCTURAL MASONRY CONTRACTOR" OR A "CERTIFIED STRUCTURAL MASON" AS <br />RECOGNIZED BY THE FLORIDA CONCRETE AND PRODUCTS ASSOCIATION (FC&PA). THE SENIOR MASONRY <br />SUPERVISOR WILL BE RESPONSIBLE TO ASSURE THAT THE WORK IS ACCOMPLISHED IN ACCORDANCE WITH <br />THE CONTRACT DOCUMENTS. THE MASONRY CONTRACTOR SHALL SUBMIT CREDENTIALS FROM THE FC&PA <br />TO THE ENGINEER FOR REVIEW AND APPROVAL PRIOR TO BIDDING. <br />2, 500 PSI REGULAR WEIGHT FOR FOOTINGS, AND SLAB -ON -GRADE <br />STRUCTURALSTEEL: <br />3,000 PSI REGULAR WEIGHT FOR BEAMS, COLUMNS, AND 5" STRUCTURAL TERRACE SLAB. <br />THE MATERIAL, FABRICATION, AND ERECTION OF STRUCTURAL STEEL SHALL COMPLY WITH THE <br />SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS, <br />CONTRACTOR SHALL SUBMIT PROPOSED MIX DESIGNS, WITH HISTORICAL STRENGTH DATA FOR EACH SEPARATE MIX PRIOR TO <br />9TH EDITION, BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION. STRUCTURAL STEEL SHALL BE ASTM <br />CONCRETE PLACEMENT. CONCRETE SLUMP SHALL NOT EXCEED 5'-1- PRIORTO THE ADDITION OF PLASTICIZER. <br />A36/A36M, Fy = 36 Mi FOR ANGLES, PLATES, AND W-SHAPES. STRUCTURAL TUBING SHALL BE ASTM <br />A500/A500M, GRADE 8, Fy = 46 Mi. STRUCTURAL PIPE SHALL BE ASTM-A53/A53M, GRADE B, TYPE E OR S, <br />CONCRETE SHALL COMPLY WITH ALL THE REQUIREMENTS OF ACI 318-14 AND ASTM C-941C-94M OR MEASURING, MIXING, <br />Fy=35 ksi. TUBE AND PIPE COLUMNS SHALL BE CONCRETE -FILLED IN THE SHOP. <br />TRANSPORTING, ETC. CONCRETE TICKETS SHALL BE TIME -STAMPED WHEN CONCRETE IS BATCHED. THE MAXIMUM TIME ALLOWED <br />FROMWHEN WATER IS ADDED TO THE MIX UNTIL IT IS DEPOSITED IN ITS FINAL POSITION SHALL NOT EXCEED 90 MINUTES. IF FOR ANY <br />ANCHOR BOLTS AT THE COLUMN BASES SHALL BE ASTM A307 BOLTS WITH DOUBLE -NUT LEVELING. ALL <br />REASON THERE IS A DELAY IN SUCH THAT A BATCH IS HELD FOR LONGERTHAN 90 MINUTES, THE CONCRETE SHALL NOT BE PLACED. <br />OTHER BOLTS SHALL BE ASTM F3125IF3125M BOLTS WITH WASHERS UNDER THE TURNED ELEMENT. BOLTS <br />IT SHALL BE THE RESPONSIBILITY OF THE TESTING LABORATORY TO NOTIFY THE OWNERS REPRESENTATIVE AND THE CONTRACTOR <br />SHALL BE TIGHTENED IN ACCORDANCE WITH THE TURN -OFF -THE -NUT METHOD. <br />OF ANY NON COMPLIANCE WITH THE ABOVE <br />ALL ANCHOR BOLTS SHALL BE GALVANIZED STEEL <br />REQUIRED CONCRETE COVERAGE OVER REBAR SHALL BE AS FOLLOWS: <br />A 3' FOR CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH (FOUNDATIONS): <br />B. FOR CONCRETE EXPOSED TO EARTH AND/OR WEATHER <br />1.12' FOR MiAND SMALLER <br />Y FOR#6 AND LARGER <br />C. FOR CONCRETE NOT EXPOSED TO WEATHER <br />3/4" FOR SLABS, WALLS AND JOISTS <br />1-1R' FOR BEAM AND COLUMN PRIMARY REINFORCEMENT, TIES, STUMPS <br />FASTENER SCHEDULE <br />WINDOW AND <br />DOOR BUCK <br />FASTENERS <br />FASTENER <br />APPUUDON <br />SI]E <br />SMCINO <br />REMPAItB <br />APPLIGTNIN <br />SIZE <br />I TYPE <br />I SPOLING <br />REMARKS <br />1 PTFURiXNOTO <br />USE HARDENED COIL <br />OARAGEDOORBLCK <br />'DA <br />—NMASJNRI <br />1f, EMBED., 4- END ST.. <br />MAeONRYICONC, <br />NNL I1 LONG <br />9.00 <br />TOMASONRY.DJPD. <br />NO WA.SNER <br />FASTE,`FR <br />8010 <br />IIlr... DST. <br />SGOpAL. E%T DOORS <br />USE HARDENED COIL <br />S"O.G <br />W1NGpWIp00lU FASTENED <br />GARAGE DOOR BLCN <br />3/b'DA Oft <br />2°DA <br />IXPAN&CN BOLT <br />12S'. 3�B 'Al <br />4"END <br />EMpEDGEDBTUs <br />T.SEENOTEe <br />-11 i?LONG. <br />STAGGERED <br />INTO MASCNRYICONC. <br />TO III— <br />TMETAL <br />]4.OIC (1?DA) <br />WINpO'N SICK <br />USE HARDENEDCOIL <br />B'OfC <br />WINDOW/DOCIMFABTENED <br />STRAY TO <br />CONTACT THIS ENGINEER FOR SPACING <br />a PT, SEE NOTES <br />NFL NY LONG. <br />STAGGERED <br />INTO MAsoNarDONc. <br />MASONRY/CONC. <br />REQUIREMENTS <br />IXT. BWNODOOR <br />R13I16W <br />'TAPCfxJ' <br />1B"m <br />11/YEMBED. BEND. <br />NON-BEAPoNG WCOD <br />11Y° ExPANSION _-_ 4TIMBEp.<" <br />BULK. PT, SEE NOTE 8 <br />NO WASHER <br />FASTNER <br />.11 E D <br />ALL TO 00- SLAB <br />WI WASHER BOLT GIST.. 3" EDpE DST. <br />.PT WIN.W.-0.138°PAFz3 f/B" 9'O•C IIIY <br />Pt T06TEEL OJL., SEE W/WASHER STAGGERED <br />NOTES <br />1. SDST <br />TAPLES SHALL NOT BE USED FOR ANY STRUCTURAL APPLICATIONS <br />2. FASTENING OF GARAGE DOORS, WINDOWS AND EXTERIOR SWING DOORS TO FRAMING BUCKS SHALL BE AS PER MANUFACTURER'S SPECS AND / OR NOA <br />3. ALL FASCIA MATERIAL SHALL BE HAND FRAMED <br />4. PAF SHALL BE HILTI X-ZF HEAVY DUTY PINS OR EQUAL SAME DIAMETER AS SPECIFIED HEREIN <br />5. FASTENER SPACING FOR THE BUCKS SHALL BE THE STRICTER REQUIREMENT OF THE NOA OR THE SPACING DETAILED ABOVE <br />6. WINDOW AND DOOR BUCKS SHALL BE AS W DE OR WIDER A$ THE DOOR OR WINDOW FRAME EXCEPT FOR AN EXTERIOR SWNG DOOR WTH A WOOD DOOR FRAME, 1x MEMBERS ARE NAILED AND <br />2x MEMBERS ARE SECURED WI TAPCONS OR PAF TO THE SUBSTRATE. <br />1441 N. RONALD REAGAN BLVD <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-7744078 <br />www.abdesigngroup.com <br />AA #: 0003325 <br />O <br />W <br />i� <br />r <br />A <br />9 <br />avaa:v. & 70 . <br />ABBOTT PARK <br />LOT #5 <br />BLK. #13 <br />PROJECT# <br />04181.000-05131 <br />MoaEL: <br />2554-E301- <br />"DARWIN" <br />GARAGE SWING: <br />RIGHT <br />PAGE: <br />DETAILS <br />160 MPH E ° C <br />17 <br />SCALE: 1/4"=1'-0" <br />SHEET <br />SN1 <br />