My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7688 Sail Clover Ln
Zephyrhills
>
Building Department
>
Building Plans
>
7688 Sail Clover Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 7:48:51 PM
Creation date
2/24/2025 9:26:16 AM
Metadata
Fields
Template:
Building Plans
Street #
7688
Location
Sail Clover Ln
Contractor
D R Horton
Building Plans - Permit #
3304
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INSTALL 6' SELF -ADHERING <br />MEMBRANE FLASHING OVER <br />TOP, SIDE(S) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SEQUENCE OF FLASHNG TO BE, <br />I. BOTTOM. 2. SIDES. S. TOP <br />VENT CAP IS TO BE SET IN BED <br />—SIDES <br />.•.h- <br />OF SEALANT AT TOP AND <br />ONLY. 8EALANT IS TO BE <br />TOOLED 60 AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />i <br />' <br />JOINTS AND INTERSECTIONS <br />APPLY SEALANT AT PERIMETER OF <br />BACKER ROD <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDE& X' CAULKING a JOINT <br />ALL AROUND <br />I I <br />I I <br />PER SECTION <br />I <br />Elderior Il Minp and pi staring <br />BACKER ROD <br />I <br />Exterior use of Portland cement plaster <br />shall comply with the application <br />X. <br />requirements of ASTM C 926-18b. <br />I <br />�:. <br />x <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1083-19a, <br />or ASTM 1787. <br />WRB LAYER 9, <br />I <br />STUCCO WRAP <br />HOODED VENT <br />i' THICK, 3 COAT CEMENT <br />I, <br />PLASTER <br />METAL LATH <br />WRB LAYER -2, FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />© DRYER <br />VENT (FRAME) <br />iZ <br />D SHEATHING <br />LAYER 9, <br />CO WRAP <br />LAYER 4, FORTIFIBER <br />DING PAPER <br />WOOD <br />CONSTUCTION <br />AL LATH <br />V CMN YL CABIN. BEAD <br />AISED BIND <br />.... O JS' MID -WALL <br />P aCRElD <br />i <br />IDE STRIP SELF <br />-- ESIVE FLASHING, CLEAN <br />ONRY BEFORE APPLYING <br />ASHING <br />STONE VENEER <br />OVER SCRATCH COAT <br />HORIZONTAL WEEP SCREED <br />W/STONE VENEER <br />(FRAME TO BLOCKZ <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER •1, STUCCO WRAP) <br />WRB LAYER 02 (FORTIFIBER ------ <br />BUILDING PAPER) <br />METAL LATH x—x—X—x <br />STUCCO <br />WOOD OR '1/16' ZIP WALL <br />SHEATHING <br />SELF-ADHESIVE FLASHING — — — — — <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R103.1.1 / ASTM C-841-14a, MIN. 2B LBS. <br />PER SQ. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />FLASHING <br />UNIT <br />PREMANUF. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT • <br />TOP 4 SIDES <br />FjB DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' <br />PIPE THROUGH / <br />WALL <br />I <br />6' SELF ADHESIVE — <br />FLASHING (INSTALL <br />PER MANW. SPECBJ <br />BUILDING PAPER <br />UNDER 'QUICK FLASH' <br />A VENT PENETRATION <br />SCALE: N.T.S. <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />AREA TO RECEIVE <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />I <br />i <br />�ELEG. METER FIELD <br />VERIFY LOCATION <br />CONSTRUCTION <br />WOOD SHEATHING <br />WRB LAYER 01, <br />STUCCO WRAP <br />WRB LAYER "Z, FORTIFIBER <br />BUILDING PAPER <br />THICK, 3 COAT CEMENT <br />V TO V MID -WALL <br />WEEP SCREED <br />:6' SELF-ADHESIVE <br />FLASHING <br />WOOD FRAMED <br />- , 4�� <br />WALL <br />HORIZONTAL WEEP SCREED <br />(FRAME TO FRAME) <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />"- —A � a" """ R SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />::O SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LAYER "I, <br />STUCCO WRAP <br />WOOD SHEATHING <br />WOOD 8 - EATWM <br />LAYER 9, <br />STUCCO WRAP <br />LAYER a2. FORTIFIBER <br />BUILDING PAPER <br />METAL LATH <br />WOOD Tro' TEXTURED <br />CONSTRUCTION :y�FINISH a WOOD <br />FASTEN TO WOOD STRUCTURAL <br />MEMBER a T' OG. MAX <br />S. <br />CMU <br />X' TO 1f' MID•WlALL <br />E] <br />•• 6' WIDE STRIP SELF <br />g' ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYING <br />V FINIGN a MASONRY <br />(�oHORIZONTAL WEEP SCREED <br />( FRAME TO BLOCK) <br />UIRB LAYER 01, <br />STUCCO WRAP <br />CUT 'X' INTO <br />SELF -ADHERING <br />MEMBRANE FLASHING <br />APPLY SELF-ADHERINGa <br />MEMBRANE FLASHING <br />OVER BOX AMC) OVER <br />APPROVED WRB <br />LAYER 9 <br />STEP #i STEP #2 <br />HOUSEWIRAP <br />_. <br />:.. :.. <br />WPM LAYER h, <br />BELOW <br />BELOW <br />STUCCO WRAP <br />CUT SUCH THAT <br />9 <br />APPLY 60 MIN <br />SELF -ADHERING <br />NO MEMBRANE <br />GRADE 'D' FELT <br />MEMBRANE FLASHING <br />ENTERS BOX, <br />OVER <br />APPLY TO FACE <br />SELF -ADHERING <br />EDGE <br />FLASHING OVER <br />APROVED <br />HOUSEWRAP <br />WRB LAYER 02, FORTIFIBER <br />BUILDING PAPER <br />STEP 03 <br />STEP 1*4 <br />APPLY E-Z BEAD <br />OVER 60 MIN <br />GRADE 'D' <br />FELT -PROVIDE <br />SEALANT AT ALL <br />JOINTS AND <br />INTERSECTIONS <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-7746078 <br />FAX: 407-7744078 <br />www.abdesigngroup.com <br />AA C 0003325 <br />y <br />14 <br />o <br />'I <br />Y <br />B <br />O <br />b <br />ash <br />IA <br />8D <br />LJIv. allLOT.BBOTT PARK <br />LOT# 4 <br />BLK. 13 <br />ROJECTry <br />04 .000- 413 <br />MODZU <br />4EAB <br />"1672-ARIA" <br />OAP —WE SMINO: <br />RIGHT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />160 MPH EXP. C <br />ELASTOMERIC r JAM <br />COATING OVER <br />STUCCO/ C.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />METAL LATH <br />STEP *S STEP 1*6 <br />ELECTRICAL RECEPTACLE <br />F-PalarrDA 09/21/21 <br />SCA* M 1/4-=1'-0" <br />SKEET <br />WA2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.