HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT ALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER FMC 1T14 EDITION (2020) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 01 CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES &HALL NOT BE LOCATED CLOSER THAN W FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 1TH EDITION (2020) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 1TH EDITION <br />(2020) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES &HALL BE <br />MECHANICALLY VENTED N ACCORDANCE WITH FBC 1TH EDITION (2020) MECHANICAL CODE SECTION <br />403. <br />a. ALL EXHAUSTED BATH ROO'1&, &HALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9. ALL FIRE RATED CEILINGS AND WALLS SWALL HAVE AN APPROVED FIRE OR FIREAMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND POO 1TH <br />EDITION (2020) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />IL DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH POP 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR 1 WAY DIFFUSER <br />— <br />SOLID LINE• SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TRUNK <br />BALANCING DAMPER OR ODD <br />0 <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN • LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />m <br />PASS-THRU AIR GRILL <br />AL WVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />SECURE STRAP TO CONC. <br />CONDENSER <br />ATTIC <br />W/ (2)•3/16'X2' TAPC," <br />UNIT <br />SIB W5 ROLL STRAP <br />EMPSQOUN AL <br />CEILING <br />O <br />O <br />EXTERIOR WALL <br />PLENUM <br />y <br />AIR RETURN <br />4 COJC�TE �� SECURE STRAP TO UNIT W/ (2) <br />13XI 1/4' BHT. MRL. SCREWS <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />CONDENSER UNIT <br />AIR HANDLER <br />y <br />CONNECTION TO PAD <br />EXTERIOR WALL <br />y <br />5/4' PVC CONDENSATE DRAIN LINE <br />NOTE, MAIN COND. DRAIN 3/4' 0IA. <br />OVER HEAD • 12' FROM STRUCTURE <br />EVAP. TRAY <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />q <br />REFRIGERANT LINES TO <br />PLATFORM <br />RETURN <br />CONDENSING UNIT <br />TRAP DRAM LINE AND TERMINATE <br />N AN APROVED DRAIN, AS PER <br />FDCR 1TH EDITION (2020) <br />MECHANICAL BLDG. CODE <br />SECTION 3012.4 <br />HVAC <br />DRAINS <br />SCORIATED NICKEL FIN. FLOOR COUNTERBUW <br />BRONZE FL. PL. I--,— OR WALL CO. PLUG <br />BRASS PLUG <br />FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />WADE 8240-K JOSAM 56000 <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.V.0 OPTUSPEC <br />FLOOR SLAB CLEAN -OUT (T <br />FIN. GRAPE <br />OR PAVING <br />SEE SPEC. <br />1'-&'X&' CONC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />�EXT. GROUND CLEAN -OUT (TYY <br />MECHANICAL PLAN <br />SCALE: 1/4 • 1'-0' <br />NOTE. <br />ALL MECHANICAL EQUIPMENT <br />SHALL BE INSTALLED AT OR <br />ABOVE F.P.E. ELEVATION. <br />■ <br />gLII <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL32750 <br />PH: 407-774-6079 <br />FAX:407-7744078 <br />www.abde igngroup.com <br />AA #: 0003325 <br />at <br />! <br />B <br />a <br />a <br />o <br />sunDiv. ae LOT: <br />ABBOTT PARK <br />LOT# 4 <br />BLK. 13 <br />PROJECT# <br />41 1.000-04 31 <br />MODzu <br />4EAB <br />"1672-ARIA" <br />OARAOa 9WtXG: <br />RIGHT <br />PAGE: <br />MECHANICAL <br />PLAN <br />%160 MPH EXP. C <br />DA � 09/21/21 <br />scALE: 1/4"=1'-0" <br />srx>zr <br />M1 <br />