Laserfiche WebLink
INSTALL 6' SELF -ADHERING <br />MEMBRANE FLASHING OVER <br />TOP, SIDE(S) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SECAJENCE OF FLASHING TO BE, <br />X: <br />I. BOTTOM. 2. SIDES, 3. TOP <br />VENT CAP 18 TO BE SET M BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT 16 TO 6E <br />j <br />TOOLED 60 A& TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />.X:: <br />E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />1• <br />JOINTS AND INTERSECTIONS <br />APPLY SEALANT AT PERIMETER OF <br />BACKER ROD <br />NON -MOVABLE FRAME AND STUCCO <br />X CAULKRJG 0 JOINT <br />OALNL <br />ALLLSSIINDDES, <br />PER SECTION <br />E Ilw1or hMng and pinteAno <br />BACKER ROD <br />I I <br />Exterior use of Portland cement plaster <br />shall comply with the application <br />requirements of ASTM C 92618b. <br />1 <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1053-19a, <br />or ASTM 1787. <br />WRS LAYER 01, <br />X. <br />STUCCO WRAP <br />HOODED VENT <br />TWICK 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />WRB LAYER -2, FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER VENT <br />(FRAME) <br />r <br />SHEATHING <br />IFIBER <br />ING PAPER <br />G� UCTION <br />--METAL LATH <br />a' CMJ VINYL CASING BEAD <br />6' RAISED BAD <br />J6' TO )j' MID•uIALL <br />WEEP SCREED <br />a <br />6' WIDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MAWNRY BEFORE APPLYNG <br />Z FLASHING <br />STONE VENEER <br />OVER SCRATCH COAT <br />HORIZONTAL WEEP SCREED <br />VSTONE VENEER <br />(FRAME TO BLOCKI <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER 02 (FORTIRBER — — — — — <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />WOOD OR 1/1!h" ZIP WALL <br />SHEATHING <br />SELF-ADHESIVE FLASHING — — — — — <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R103.1.1 / ASTM C-841-14a, MIN. 2.5 LBS. <br />PER SQ. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />FINISH <br />SELF ADHESIVE <br />WOOD CONSTRUCTION <br />OVER TOP 4 SIDES <br />SELF <br />/ WOOD SHEATHING <br />FLASHING: <br />WRB LAYER PI, <br />UNIT <br />STUCCO WRAP <br />F6' <br />PREMANUF. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />WRB LAYER 02, FORTIFIBER <br />BUILDING PAPER <br />SEALANT is <br />TOP SIDES <br />THICK, 3 COAT CEMENT <br />PLASTER <br />0DRYER VENT (BLOCK) <br />��P MISCREEDD-WALL <br />WOOD <br />CONSTRUCTION <br />6' SELF-ADHESIVE <br />FLASHING <br />a' CM <br />BUILDING PAPER <br />OVER 'QUICK <br />WOOD FRAMED <br />_ _ _ <br />FLASH' I— 7 <br />WALL <br />HORIZONTAL <br />WEEP SCREED <br />•' ' <br />PIPE THROUGH / <br />WALL <br />( FRAME <br />TO FRAME) <br />6' SELF ADNESIVE— <br />FLASHING (INSTALL <br />PER MANIF. SPECS.) <br />BUILDING PAPE'. <br />UNDER 'QUICK FLASI <br />A1VENT PENETRATION <br />SCALE: N.T.S. <br />ELEC. METEF <br />VERIFY LO <br />,4r= i IV ICLC..LIYC <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />I <br />ELEC. METER FIELD <br />Y\ VERIFY LOCATION <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />-('GREAT STUFF' OR SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />TWAT ELEC. WIRE PENETRATES <br />PROVIDE STUCCO SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED HOUSEWRAP <br />FOR DOX INSTALLATION <br />WRB LAYER 01, <br />STUCCO WRAP <br />WOOD SHEATHIWx <br />HOUSED R.AP <br />BELOW <br />CUT SUCH THAT <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY TO FACE <br />EDGE <br />APPLY E-Z BEAD <br />OVER 60 MIN <br />GRADE 'D' <br />FELT -PROVIDE <br />SEALANT AT ALL <br />JOINTS AND <br />INTERSECTIONS <br />WOOD BREATHING <br />.. LAYER 9, <br />STUCCO WRAP <br />WRS LAYER -2, FORTIFIBER <br />BUILDING PAPER <br />METAL LATH <br />FASTEN TO WOOD STRUCTURAL <br />MEMBER • V OL. MAX <br />V TO Jp MID•WALL <br />eYRe_ MP M <br />&'WIDE STRIP SELF <br />ADWE61VE FLASHING, CLEAN <br />MASONRY BEFORE APPLYNG <br />V FINISH • MASONRY <br />® HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK <br />S' <br />WRB LAYER 91, <br />STUCCO WRAP <br />WRB LAYER 01, <br />STUCCO WRAP <br />9 APPLY 60 MIN <br />GRADE '0' FELT <br />SELF -ADHERING <br />MEMBRANE FLASHING <br />_ <br />OVER <br />SELF -ADHERING <br />FLASHING OVER <br />APROVED <br />HOUSEWRAP <br />U1R5 LATER 02, FORTIFI15ER <br />BUILDING PAPER <br />5TEF 1*3 <br />5TEP <br />1*4 <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ C.Y. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />METAL LATH �+ <br />�J <br />STEP 05 STEP #6 <br />(9) ELECTRICAL RECEPTACLE <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-7746078 <br />FAX: 407-774.4078 <br />www.abdeelip4mup.com <br />AA N: 0003325 <br />s� <br />AN <br />SR <br />o <br />� <br />5 <br />aUNDIV. a LOT: <br />ABBOTT PARK <br />LOT #39 <br />BLK #7 <br />PRDJICCTSI <br />04 81.000-3907 <br />MODZU <br />4EHB <br />"2605- HAYDEN" <br />GARAGE a11111INO: <br />RIGHT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />160 MPH C <br />2 P 241 <br />DRINT <br />A 09/21/21 <br />aCALM 1/4"=1'-0" <br />aFIEET <br />WA2 <br />