ROOF WIND DESIGN PRESSURES
<br />NET (GROSS) ASCE 7-16
<br />ZONE 1 = 58.00 PSF (68.00)
<br />ZONE 3 = 66.50 PSF (76.50)
<br />ZONE 2e = 66.50 PSF (76.50)
<br />ZONE 3e = 76.60 PSF (86.60)
<br />ZONE 2n = 76.60 PSF (86.80)
<br />ZONE 3r = 91.70 PSF (101.70)
<br />ZONE 2r = 76.60 PSF (86.60)
<br />"A"- 4'-0" END ZONE DISTANCE
<br />BASIC WIND SPEED: 160 MPH
<br />EXPOSURE CATEGORY: "C.
<br />RISK CATAGORY: II
<br />APPLICABLE INTERNAL
<br />PRESSURE COEFFICIENT: +/-0.18
<br />ROOF DIAPHRAGM
<br />FOR ASPHALT SHINGLE ROOF, USE MIN 19/32" STRUCTURAL SHEATHING
<br />EXP 1 (40120), FOR CEMENTITIOUS TILE AND METAL ROOFING, USE MIN.
<br />19132" STRUCTURAL SHEATHING EXP 1 (40R0).(SEE TABLE FOR FIELD
<br />AND EDGE SPACING) SEE DETAIL
<br />ROOF SHEATHING TO GABLE END FRAME USE 10d RING SHANK GUN
<br />NAILS @ 4" O.C. EDGEWISE 2x4 BLOCKING ALL PANEL JOINTS WIN 4' R
<br />GABLE END.
<br />ROOF/ WALU FLOOR
<br />SHEATHING
<br />FASTENER SCHEDULE
<br />NAIL REQUIREMENTS
<br />SIZE
<br />HEAD
<br />LENGTH
<br />CA.
<br />I TENSILE STR.
<br />SHANK
<br />ASTM
<br />10d
<br />RING SHANK,
<br />2 1I7
<br />0131
<br />F1807
<br />K
<br />170,000
<br />NG
<br />((11I6--20 RINGS
<br />RSRS-03
<br />8d
<br />RING SHANK,
<br />2 31V
<br />0,113
<br />F1667
<br />SCREW SHANK
<br />PER INCH)
<br />RSRS-01
<br />Sd
<br />RING SHANK
<br />PNEUMATIC
<br />23/8"
<br />0,113
<br />F1887
<br />SCREW -NAILS
<br />RSRS-01
<br />RAFTER OR TRUSS
<br />ROOF SHEATHING
<br />EXTERIOR SHEATHING
<br />USE 1/2" CDX OR 7/16" O.S.B. PLY WITH 8d RING SHANK GUN NAILS AT 4"
<br />o
<br />O.C. AT PANEL SIDES AND Bd RING SHANK GUN NAILS 4" O.C. TOP &
<br />BOTTOM PANEL AND 8d RING SHANK GUN NAILS AT 6" O.C. AT
<br />m
<br />INTERMEDIATE SUPPORTS OR 7/16" ZIP SHEATHING SYSTEM (INSTALLED
<br />PER MANUF. SPECS.) SEE DETAIL
<br />1. BUILDING LENGTH
<br />1.
<br />ZONE 1: 10d NAILS @ 4" O.C. ON EDGE AND 6.O.C. IN FIELD
<br />ZONE 2e, 211, 2,'. 10d NAILS @ 4" O.C. ON EDGE AND 4" O.C. IN FIELD
<br />ZONE 3,3e, 3r. 10d NAILS @ 4" O.C. ON EDGE AND 4" O.C. IN FIELD
<br />NOTE ROOF SHEATHING THICKNESS WAS CALCULATED
<br />AND ADHERES TO ASCE 7-16
<br />H
<br />2®
<br />yo
<br />Ba RING SHANK GUN NAIS 0-C.
<br />TOP A BOTTOMEDC£S
<br />TYP. EXT. SHEATHING ATTACHMENT
<br />ROOF SHEATHING LAYOUT
<br />AND ENOWALL BRACING
<br />FOR GABLE ENO FRAMING
<br />NOTE: GABLES -DROP GABLE END & (1) ADD'L DROPPED
<br />TRUSS 2x4 #2 SYP OUTLOOKER RAFTER W/ BLOCKING @
<br />16"O. C. IF NO DROPPED GABLE END, ATTACH 2x4#2 SYP
<br />BLOCKING @ 16" O.C. FIRST 4 BAYS W/ (2)12d NAILS EA
<br />END. ATTACH ROOF SHEATHING TO RAFTERS 2/
<br />BLOCKING PER NAILING SCHEDULE
<br />6
<br />IN RING SHANK GUN NAILS
<br />a SEE "ROOF SHEATHING ATTACHMENT'
<br />m o TABLE FOR FIELD SPACING
<br />ze
<br />8
<br />TYP. EXT. SHEATHING ATTACHMENT FOR STRUCTURAL ROOF
<br />SHEATHING
<br />#8 2" DECK SCREWS 0 6'-8" O.C. MAX @
<br />EDGES & 12" O.C. MAX IN FIELD. UNTHREADED
<br />0 o SHANK TO EXTEND BEYOND THICKNESS OF
<br />SUB -FLOOR SHEATHING
<br />�e
<br />TYP. 3/4" TOG SUB -FLOOR DECKING GLUED TO ALL EXPOSED MEMBERS
<br />GENERAL NOTES:
<br />STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOB SPECIFICATIONS AND
<br />ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND SITE DRAWINGS. CONSULT
<br />ARCHITECTURAL DRAW NGS FOR SLEEVES, DEPRESSIONS, AND OTHER DETAILS NOT SHOWN
<br />ON STRUCTURAL DRAW NGS. APPLICABLE BUILDING CODE STANDARDS: FBC4R 2020, 7th EDITION
<br />ACI 318-14, BUILDING CODE REQUIREMENTS
<br />FOR STRUCTURAL CoNCRETE, TMS 4021602-16 AISI SPECIFICATION FOR THE DESIGN OF
<br />COLD -FORMED STEEL STRUCTURAL MEMBERS 2016, ASCE 7-16 ANDAISC SPECIFICATIONS
<br />ALL DETAILS AND SECTIONS SHOW ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND
<br />SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE ON THE PROJECT,
<br />EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN.
<br />ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD. DO NOT SCALE THE
<br />DRAW NGS. FOLLOW WRITEN DIMENSIONS ONLY. ANY DISCREPANCIES SHALL BE BROUGHT
<br />TO THE ATTENTION OF THE HI ARCHITECT PRIOR TO PROCEEDING WITH THE AFFECTED PART
<br />OF THE WORK.
<br />THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND STABLE AFTER THE BUILDING
<br />IS COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES AND
<br />SEQUENCES TO INSURE SAFETY OF THE BUILDING AND ITS COMPONENTS
<br />DURING ERECTION. THIS WORK INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING,
<br />TEMPORARY BRACING, GUYS OR TIE -DOWNS.
<br />THE CONTRACTOR SHALL SUPPLEMENT THE MINIMUM REQUIRED FOUNDATION AND SITE PREPARATION
<br />REQUIREMENTS AND SLAB-0N-GRADE THICKNESS TO HANDLE CONSTRUCTION LOADS.
<br />DO NOT SCALE DRAWINGS. THE CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR
<br />TO WORK PERFORMED AND SHALL NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND.
<br />DESIGN LOADS:
<br />ROOF: LIVE LOAD FLOOR: LIVE LOAD 40 psi
<br />20 pV TOP CHORD non -concurrent
<br />10 psf BTM CHORD no -current
<br />DEAD LOAD DEAD LOAD
<br />18 PM TOP CHORD 20 psf TOP CHORD
<br />(7 psf Nd ASPHALT SHINGLES) (10 paf W/ W GYPCRETE)
<br />10 PST BTM CHORD 5 psf BTM CHORD
<br />DEAD LOAD TO RESIST WND UPLIFT: 1 Opsf
<br />BALCONY LIVE LOAD 60 psf
<br />STAIRS LIVE LOAD 40 psf
<br />WND: DEAD LOAD SPEED =160 MPH 3-SECOND GUST
<br />(ASCE 7-10 (FBC R2020) EXPOSURE C, RISK CATEGORY II)
<br />LIVE LOADS: UNINHABITABLE ATTIC WITHOUT STORAGE: 10psf, UNINHABITABLE ATTIC WTH LIMITED
<br />STORAGE: 2Dpsf, 14481TABLE ATTICS AND ATTICS SERVED WITH FIXED STAIRS: 30psf, BALCONIES (EXTERIOR)
<br />AND DECKS: 40psf, GUARDS AND HANDRAILS: 200psf, GUARDINFILL COMPONENTS: 50psf, PASSENGER
<br />VEHICLE GARAGES: 50psf, ROOMS OTHER THAN SLEEPING ROOM: 40psf, SLEEPING ROOMS: 30psf, STAIRS:
<br />40Psf
<br />SHOP DRAWING REVIEW:
<br />SHOP DRAWINGS WILL BE REVIEWED FOR GENERAL COMPLIANCE WITH THE DESIGNING INTENT
<br />OF THE CONTRACT DOCUMENTS ONLY. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
<br />COMPLIANCE WTH THE CONTRACT DOCUMENTS AS TO QUANTITY, LENGTH, ELEVATIONS, DIMENSIONS, ETC.
<br />ALL SHOP DRAWINGS SHALL BE REVIEWED BY THE CONTRACTORS PRIOR TO SUBMITTAL TO THE ARCHITECT.
<br />DRAW NGS SUBMITTED WITHOUT REVIEW WLL BE RETURNED UNCHECKED. SHOP DRAWINGS IN THE FORM
<br />OF REPRODUCIBLE SEPIAS OF STRUCTURAL DRAWINGS (CON -TRACT DOCUMENTS) ARE PROHIBITED
<br />WITHOUT THE EXPRESS WRITTEN PERMISSION FROM THE ENGINEER. IN ALL INSTANCES, THE CONTRACT
<br />DOCUMENTS WILL GOVERN OVER THE SHOP DRAWINGS CHECKED, UNLESS OTHERWSE SPECIFIED IN
<br />WRITING BY THE ARCHITECT.
<br />FOUNDATION/ SITE PREPARATION:
<br />FOOTINGS WERE DESIGNED FORAN ALLOWABLE SOIL BEARING PRESSURE OF 2,000 PSI, FOOTING
<br />EXCAVATIONS AND SLAB SUB -GRADE SHALL BE COMPACTED TO A DRY DENSITY OF AT LEAST 95% OF THE
<br />MODIFIED PROCTOR MAXIMUM DRY DENSITY, DETERMINED IN ACCORDANCE WITH ASTM D-1557. TREAT ALL
<br />SOIL FOR TERMITE PROTECTION,
<br />THE OWNER SHALL RETAIN THE SERVICES OF AN INDEPENDENT GEO-TECHNICAL ENGINEER TO VERIFY
<br />SUCCESSFUL COMPLETION OF SITE PREPARATION EFFORTS. LOCATIONS FAILING TO MEET THE
<br />GEO-TECHNICAL ENGINEERS REQUIREMENTS SHALL BE RE -COMPACTED AND RETESTEDAT THE
<br />CONTRACTOR'S EXPENSE, AND AS DIRECTED BY THE ARCHITECT. WRITTEN CERTIFICATION THAT THE
<br />MINIMUM DESIGN BEARING CAPACITY, AND THAT THE COMPACTION REQUIREMENTS HAVE BEEN MET SHALL
<br />BE MADE BY THE GEO-TECH. ENGINEER
<br />CONCRETE:
<br />CONCRETE SHALL ACHIEVE MINIMUM 28 DAY COMPRESSIVE STRENGTHS AS FOLLOWS:
<br />2,500 P31 REGULAR WEIGHT FOR FOOTINGS, AND SLAB ON -GRADE
<br />3,000 PSI REGULAR VVEIGHT FOR BEAMS, COLUMNS, AND 5" STRUCTURAL TERRACE SLAB.
<br />CONTRACTOR SHALL SUBMIT PROPOSED MIX DESIGNS WITH HISTORICAL STRENGTH DATA FOR EACH SEPARATE MIX PRIOR TO
<br />CONCRETE PLACEMENT. CONCRETE SLUMP SHALL NOT EXCEED 5' d- PRIOR TO THE ADDITION OF PLASTICIZER
<br />ALL AGGREGATE USED IN CONCRETE SHALL CONFORM TO ASTM C33/C33M. MAJOMUM AGGREGATE SIZE SIALL BE 31C.
<br />WOOD:
<br />PROVIDE 6%AIR ENTRAINED CONCRETE EXPOSED TO EARTH OR WEATHER NON -BEARING WOOD WALLS TOP PLATES & STUDS CAN BE SPF
<br />ALL EXPOSED EDGES OF CONCRETE ARE TO BE CHAMFERED 3/4'.
<br />ALL WOOD FOR BEAMS, BEARING WALLS, SOLE PLATES, TOP PLATES, BRACING, LEDGERS, BLOCKING,
<br />CRIPPLERS, SILLS, ETC., SHALL BE SOUTHERN PINE NO. 2 OR BETTER. Fb = 1100 PSI AND MODULUS OF
<br />PROVIDE 6-MIL CONTINUOUS POLYETHYLENE VAPOR BARRIER MEMBRANE UNDER ALL SIABSONGRIXRJD WHERE INDICATED ON
<br />ELASTICITY = 1,400,000 PSI. ALL WOOD IN CONTACT WITH CONCRETE OR CONCRETE BLOCK SHALL BE
<br />DRAWINGS. SEAMS LAPPED 6INCHES AND SEALED WITH ADHESIVE TAPE.
<br />PRESSURE TREATED. PRESSURE TREATED BOTTOM PLATE REQUIRED. WOOD FOR NO STRUCTURAL USES
<br />RATEDSHALL BE TO TREATMENT: UM
<br />PSTR
<br />FORMWORK
<br />HALL BE TREATED FOR ANY
<br />CORROBIDRA ETETTRA EDRALN(DOT). WOOD FOR UC URAL USE THAT SHAA
<br />FORM -WORK, SHORING, AND BRACING FOR ALL CONCRETE BEAMS, SLABS, COLUMNS, WALLS,
<br />REASON SHALL BE RATED TO RETENTION LEVELS OF 0.42 PCF FOR DOT OR MORE. NAILS, SPIKE, BOLTS USED
<br />AND FOOTINGS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WTH ACI 347 LATEST
<br />W/ DOT SHALL BE HOT DIPPED GALV. FOR STRUCTURAL USES, AVOID BUYING TREATED LUMBER THAT
<br />EDITION,'RECOMMENDED PRACTICE FOR CONCRETE FORMWORK,
<br />CONTAINS MORE THAN W OF HEARTWOOD.
<br />EXCLUSIONS FROM THESE PLANS:
<br />MINIMUM NAILING PER FBCR 2D20, 7th EDITION. SEE NAILING SCHEDULE ON PLANS.
<br />WATERPROOFING, FLASHING, SOUND ISOLATION, FIRE SEPARATION, OR OTHER NON STRUCTURAL ITEMS
<br />ARE NOT PART OF THE STRUCTURAL PLANS AS THEY ARE NOT CONSIDERED TO BE STRUCTURALDEPENDNG PROVIDE SOLID BLOCKING UNDER ALL POINT LOADS AND NDOD COLUMNS WTH 2x STRUCTURAL LUMBER
<br />ON THE TYPE OF CONSTRUCTION THESE ITEMS SOME OR ALL MAY BE REQUIRED BUT ARE BY OTHERS.
<br />SYP #Y2.
<br />WELDED WIRE MESH:
<br />WELDED WIRE MESH, SHALL BE ASTM Al 054/A1064M, GRADE 65 AND BE PLACED IN ACCORDANCE WTH THE
<br />ACI TYPICAL DETAILS. MINIMUM LAP SHALL BE ONE SPACE PLUS TWO INCHES. W RE MESH FOR SLABS SHALL
<br />BE SUPPORTED WTH 2' CHAIRS SPACED T-0.00, EACH WAY.
<br />REINFORCING STEEL:
<br />REBAR SHALL BE ASTM AOISA615M GRADE 40 IN CONCRETE DEFORMED BARS, REBAR SHALL BE ASTM A615
<br />GRADE 601N MASONRY DEFORMED BARS, FREE FROM OIL, SCALE, AND RUST AND PLACED INACCORDANCE
<br />W/ THE TYPICAL BENDING DIAGRAM AND PLACING DETAILS OF THE AG STANDARDS AND SPECIFICATIONS.
<br />CONTRACTOR SHALL SUBMIT REBAR SHOP DRAWINGS FOR REVIEW PRIOR TO FABRICATION. HORIZONTAL
<br />AND VERTICAL BARS SHALL LAP 6 x BAR NO. UNSCHEDULED FIELD LAPS ARE SUBJECT TO ENGINEERS
<br />REVIEW.
<br />TYP. MIN LAPS SHALL BE AS FOLLOWS: #4 BAR - 26' #6 BAR - 36"
<br />#5 BAR - 30" #7 BAR - 42'
<br />PROVIDE 36' x 36' CORNER BARS, BOND BEAM ONLY, LAPPED AND TIEDTO EACH BEAM REBAR, SEE DETAILS
<br />FOR ADDITIONAL INFORMATION.
<br />ALL VERTICAL REINFORCING BARS IN CMU CELLS SHALL BE ANCHORED IN THE FOOTING
<br />THICKENED SLAB, BEAM OR LINTEL SUPPORTING THE WALL AT THE TOP AND BOTTOM WITH
<br />MINIMUM 10 INCH HOOKS OR BENDS AND SHALL BE CONTINUOUS THROUGHOUT THE HEIGHT OF THE
<br />WALL.
<br />RUN REINFORCING BARS CONTINUOUSLY LAPPED AT SPLICES AND AROUND CORNERS. DOWEL
<br />INTO INTERSECTING WALLS AND HOOK AT ENDS. STAGGER SPLICES VMEREVER POSSIBLE.
<br />DO NOT CUT OR DISPLACE REINFORCING STEEL TO ACCOMMODATE THE INSTALLATION OF EMBEDDED ITEMS
<br />WITHOUT THE APPROVAL OF THE ENGINEER.
<br />MASONRY:
<br />MASONRY CONSTRUCTION AND MATERIALS SHALL CONFORM WTH ALL REQUIREMENTS R THE
<br />"SPECIFICATION MASONRY STRUCTURES" (TMS 402, BUILDING CODE REQUIREMENTS FOR MASONRY
<br />STRUCTURES AND SPECIFICATIONS FOR MASONRY STRUCTURES AND COMMENTARIES), AS PUBLISHED BY
<br />THE MASONRY STANDARDS JOINT COMMITTEE.
<br />ALL BLOCK WALLS SHALL BE TWO -CELL HOLLOW CONCRETE MASONRY REGULAR SIZE BLOCK
<br />MANUFACTURED IN CONFORMANCE WITH ASTM C-90, GRADE fm - 2000 PSI. BLOCK SHALL BE PLACED USING
<br />RUNNING BOND UNLESS OTHERW SE NOTED. LAY-UP MASONRY WALLS TO BOTTOM OF TIE BEAMS BEFORE
<br />PLACING CONCRETE FOR IN -WALL COLUMNS. GROUT USED TO FILL MASONRY CELLS SHALL COMPLY WTH
<br />ASTM C-476, AND SHALL PROVIDE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS, UNLESS
<br />SPECIFICALLY NOTED OTHERWISE ON FOUNDATION PLAN. THE GROUT MIX SHALL HAVE A MAXIMUM 3/8"
<br />COURSE AGGREGATE, AND SHALL BE PLACED NA SLUMP OF 8" TO 10'. USE ONLY MECHANICAL VIBRATION
<br />TO CONSOLIDATE GROUT.
<br />TYPE "M" OR "S" MORTAR SHALL BE USED EXCLUSIVELY ON THIS PROJECT. MORTAR SHALL BE
<br />PROPORTIONED AND MIXED AS OUTLINED UNDER ASTM C-270. HORIZONTAL AND VERTICAL MORTAR JOINTS
<br />SHALL BE 3/8" THICK UNLESS OTHERWISE NOTED. REMOVE MORTAR PROTRUSIONS THAT EXTEND INTO
<br />CELLS TO BE FILLED.
<br />FILL CMU CELLS SOLID WITH GROUT AT ALL CELLS TO RECEIVE EXPANSION ANCHORS ANCOR VERTICAL
<br />REINFORCING.
<br />LAP VERTICAL REBAR 6 X BAR NO. (48 BAR DIAMETERS)., U.N.O.
<br />STRUCTURALSTEEL:
<br />THE MATERIAL, FABRICATION, AND ERECTION OF STRUCTURAL STEEL SHALL COMPLY WITH THESPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS,
<br />9TH EDITION, BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION. STRUCTURAL STEEL SHALL SE ASTM
<br />A36/A36M, Pj = 36 ksl FOR ANGLES, PLATES, AND WSHAPES. STRUCTURAL TUBING SHALL BE ASTM
<br />A500tA500M, GRADE B, P/ = 46 ksi. STRUCTURAL PIPE SHALL BE ASTM A53/A53M, GRADE B, TYPE E OR S, Fy =
<br />35 ksi. TUBE AND PIPE COLUMNS SHALL BE CONCRETE -FILLED IN THE SHOP.
<br />ANCHOR BOLTS AT THE COLUMN BASES SHALL BE ASTM A307 BOLTS WTH DOUBLE -NUT LEVELING. ALL
<br />OTHER BOLTS SHALL BE ASTM F3125/1`3125M BOLTS WTH WASHERS UNDER THE TURNED ELEMENT, BOLTS
<br />SHALL BE TIGHTENED IN ACCORDANCE WTH THE TURN-0FF-TEWLT METHOD.
<br />CONCRETE SHKL COMPLY WITH ALL THE REQUIREMENTS OF AC1318 AND ASTM C94IC94M OR MEASURING, MANG, TRANSPORTING, ALL ANCHOR BOLTS SHALL BE GALVANIZED STEEL. JEOLTS ARE TO BE STEEL.
<br />ETC. CONCRETE TICKETS SIALL BE TIME4TAMPE2 WHEN CONCRETE IS BATCHED. THE MAXIMUM TIME ALLOWED FROM:Mf31
<br />WATER IS ADDED TO THE MIX UNTIL IT IS DEPOSITED IN ITS FINAL POSITION SHALL NOT EXCEED 90 MINUTES IF FOR ANY REASON
<br />TEE IS A DELAY IN SUCH THAT A BATCH IS HELD FOR LONGER THAN 90 MINUTES, THE CONCRETE SHALL NOT BE PLACED. IT SHALL
<br />BE THE RESPONSIBILITY OF THE TESTING LABORATORY TO NOTIFY THE OWNERS REPRESENTATIVE AND THE CONTRACTOR OF ANY
<br />NON COMPLIANCE WTH THEABOVE
<br />REQUIRED CONCRETE COVERAGE OVER REBARSHALL BE AS FOLLOWS
<br />A YFOR CONCRETE CAST AGAINST AND PERMANENTLYEGIOSEDTO EARTH(FOUNDATIONSt
<br />B FOR CONCRETE EXPOSED TO EARTH ANDIOR WEATHER
<br />1-1/2 FOR 05 AND SMALLER
<br />2 FOR #5 AND LARGER
<br />C. FOR CONCRETE NOT EXPOSED TO WEATHER
<br />3/4' FOR SLABS, WALLS AND JOISTS
<br />1.12' FOR BEAM AND COLUMN PRIMARY REINFORCEMENT, TIES, STIRRUPS
<br />UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WTH CONCRETE. SEAT PLATES SHALL BE PROVIDED
<br />AT BEARING LOCATIONS W THOUT WOODEN TOP PLATES.
<br />WOOD TRUSSES:
<br />TO BEDESIGNED AND FABRICATEDIN ACCORDANCE WITH THE "NATIONL DESIGN SPECIFICATIONS FOR
<br />STRESS -GRADE LUMBER AND ITS FASTENINGS' SY THE NFPA. TRUSS DESIGNS SHALL BE SIGNED AND
<br />SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN FLORIDA. SEE NOTED FOR SHOP DRAWINGS.
<br />CONNECTOR PLATES SHALL BE A MINIMUM THICKNESS OF 0.036' AND BE MANUFACTURED FROM STEEL
<br />MEETING THE REQUIREMENTS OF ASTMA446/A446M, GRADE A, AND SHALL BE HOT -UPPED GALVANIZED.
<br />DESIGN, FABRICATE, AND ERECT WOOD TRUSSES IN ACCORDANCE WITH TPIA4, "DESIGN NATIONAL
<br />STANDARDS FOR METAL -PLATE -CONNECTED -WOOD TRUSS CONSTRUCTION:, AND "SCSI LATEST EDITION'
<br />COMMENTARY AND RECOMMENDATIONS FOR HANDLING, INSTALLATION BRACING METAL-PLATECONNECTED
<br />WOOD TRUSSES.
<br />TRUSS MANUFACTURER W LL PROVIDE CALCULATIONS INDICATING ADDITIONAL DEAD LOADS FOR THE ROOF
<br />LOCATIONS WTH GUSSETS, CRICKETS AND VALLEY LOCATIONS REQUIRING ADDITIONAL ROOF FRAMING FOR
<br />INTERSECTIONS OF HIGHER OR LOWER ROOFS IN ACCORDANCE WTH ANSI/ASCE 7 SO: 1990.
<br />HURRICANE STRAPS SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTRUCTIONS.
<br />CONTRACTOR SHALL SUBMIT SIGNED AND SEALED DRAWINGS FOR ALTERNATE CONNECTION DETAILS AT
<br />TRUSSES/GIRDERS TO COLUMNS AND WALLS FOR APPROVAL.
<br />ROOF & FLOOR LAYOUTS PROVIDED ON THESE PLANS ARE TO BE USED AS GUIDE FORBEARING
<br />DETERMINATIONS, FEASIBILITY & ARCHITECTURAL AIDE. TRUSS MANUFACTURER IS RESPONSIBLE FOR FINAL
<br />LAYOUT, SPANS & ALL TRUSS/ HEADER ENGINEERING. ANY DISCREPANCIES FROM THESE LAYOUTS THAT
<br />AFFECT THE STRUCTURAL BEARING AS CALLED OUT ON THESE PLANS SHALL BE NOTIFIED TO THE
<br />STRUCTURAL ENGINEER OF RECORD PRIOR TO MANUFACTURE OF TRUSSES. THE TRUSS FABRICATOR SHALL
<br />PROVIDE ENGINEERED SHOP DRAWINGS OF EACH INDIVIDUAL TRUSS AND A FULLY DIMENSIONED ERECTION
<br />PLAN SHOWING COMPONENT LAYOUT. SHOP DRAWINGS SHALL BE SIGNED AND SEALED BY A FLORIDA
<br />LICENSED PROFESSIONAL ENGINEER.
<br />THE HURRICANE STRAPS SPECIFIED ON THE WALL SECTIONS AND PLANS ARE PROVIDEDTO FACILITATE THE
<br />CONSTRUCTION SCHEDULE, AND MAY CHANGE PREDICATED ON THE TRUSS AND GIRDER REACTIONS
<br />PROVIDED BY THE TRUSS ENGINEER.
<br />THE TRUSS TO STRUCTURE CONNECTIONS AND LOADS SPECIFIED ON THIS PLAN SHALL SUPERCEDE THOSE
<br />OF THE DELEGATED TRUSS ENGINEER. WND UPLIFT VALUES RAVE BEEN BASED ON ASCE 706 COMPONENT
<br />AND CLADDING WIND LOAD PRESSURES. THE DELEGATED TRUSS ENGINEER SHALL BE RESPONSIBLE FOR
<br />ALL TRUSS TO TRUSS CONNECTIONS.
<br />FASTENER SCHEDULE
<br />WINDOW AND
<br />DOOR BUCK FASTENERS
<br />FASTENER
<br />A-GAnON
<br />Siff
<br />1.
<br />SPA.H.
<br />REMARM8
<br />APPUG m
<br />film
<br />TYPE
<br />SR1gNG
<br />REMApx3
<br />-P-RRING TO
<br />GASEHARD@1E _
<br />-111/S LONG.
<br />OMAOE DOCK BI!q(
<br />TO RASDNRYIOONC.
<br />H'OA
<br />NO�N
<br />MA60MtI
<br />EMBEMA6011RY/GONG.
<br />1DIET6GOpK.
<br />rE'
<br />IXT DOORSOfSE
<br />HARDEHEDCOIL
<br />S'o0
<br />WINDOW9WIXLFASTENEO
<br />OMOOEDOOR SN-K
<br />ORIFOIC
<br />EXPANSION BOLT
<br />816"ON.SEO.,
<br /><' ENDpST.,
<br />x T, SEEN01E6
<br />NAIL NYC LONG.
<br />3TAGOSR.
<br />IMOMASONRY INC.
<br />TO M4�MrvICON4
<br />]p_01TDW
<br />3'EDOE q3P.
<br />wINOJWBUCK
<br />GMEHARDENEDCOIL
<br />S.-
<br />WIWO DOOR)-T..
<br />METAL STRAP TO
<br />CONTACT THIS ENGINEER
<br />FOR SPACING
<br />1. PT, SEEN 6
<br />NA 11ff'L0NO.
<br />STAGGeRED
<br />INIOMASDNRYNONC.
<br />...NRYICONC
<br />REQUIREMENTS
<br />E. SNAG DOOR GGp3_ "TAPOJN' ITO. MBEGS"END.
<br />OF
<br />BUCK 3. PT, SEE NOTE6 WASHER FASTNER 16 OIST.,11R"EDGE-T.
<br />T TWINDOW .-RA1.1- a"OTC <"END. DI6T.11?
<br />PO STEEL CCL..9E£ W/ WA91ER STAGOQtEO DOE O44l.
<br />NOTE6
<br />NOTSEI
<br />11. STAPLES SHALL NOT BE USED FOR ANY STRUCTURAL APPLICATIONS
<br />2. FASTENING OF GARAGE DOORS, WINDOWS AND EXTERIOR SWING DOORS TO FRAMING BUCKS SHALL BE AS PER MANUFACTURER'S SPECS AND/ NOA
<br />3. ALL FASCA MATERIAL SHALL BE HAND FRAMED
<br />4. PAF SHALL BE HILTI XZF HEAVY DUTY PINS OR EQUAL SAME DIAMETER AS SPECIFIED HEREIN
<br />5. FASTENER SPACING FOR THE BUCKS SHALL BE THE STRICTER REQUIREMENT OF THE NOA OR THE SPACING DETAILED ABOVE
<br />6. WINDOW AND DOOR BUCKS SHALL BE AS VIDE OR UDDER AS THE DOOR OR WINDOW FRAME EXCEPT FOR AN EXTERIOR SWING DOOR WITH A WOOD DOOR FRAME. ix MEMBERS ARE NAILED AND
<br />2x MEMBERS ARE SECURED W/ TAPCONS OR PAF TO THE SUBSTRATE.
<br />1441 N. RONALD REAGAN BLVD.
<br />LONGWOOD, FL 32750
<br />PH: 407-774,6078
<br />FAX: 407-774.4078
<br />www.ebdesigngroup.com
<br />AA #: 0003325
<br />O
<br />fee!
<br />G
<br />aunDiv. Ae LrOT.
<br />ABBOTT PARK
<br />LOT #39
<br />BLK #7
<br />P1toamTo
<br />04 ,000-39 7
<br />MODZU
<br />4EHB
<br />"2605-HAYDEN"
<br />GARAGE aWMxG:
<br />RIGHT
<br />PAGE:
<br />DETAILS
<br />160 MPH EXP. C
<br />202
<br />ROIJW A ABOUC ACRA
<br />L AR NO 933723 J
<br />DvmcT
<br />ATIL. 09/21/52'1
<br />MICALIE: 1/4"=1'-0"
<br />omzzT
<br />S N1