My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7704 Sail Clover Ln
Zephyrhills
>
Building Department
>
Building Plans
>
7704 Sail Clover Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 8:17:14 PM
Creation date
2/24/2025 9:44:31 AM
Metadata
Fields
Template:
Building Plans
Street #
7704
Location
Sail Clover Ln
Contractor
D R Horton
Building Plans - Permit #
3301
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT BHBLL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER FBC lTH EDITION (2020) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />S. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, 844ALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC lTH EDITION (2020) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 1TH EDITION <br />(2020) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 1TH EDITION (2020) MECHANICAL CODE SECTION <br />403. <br />8, ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />% ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER, ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC 1TH <br />EDITION (2020) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />IL DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />BROKEN LINE. RETURN TRLINK <br />l <br />BALANCING DAMPER OR OBD <br />(' <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />m <br />PASS-THRU AIR GRILL <br />NOTE: <br />%ALL <br />HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />SECURE STRAP TO CONC. <br />CONDENSER <br />ATTIC <br />W/ (2)-3/16'X2' TAPCONS <br />UNIT <br />SIMPSON WB ROLL STRAP <br />OR EQUAL <br />CEILING <br />O <br />O <br />EXTERIOR WALL <br />PLENUM <br />T <br />y <br />AIR RETURN <br />SECURE STRAP TO UNIT W/ (2) <br />W CONCRETE SLAB l8XI 1/4' SHT, MTL. SCREWS <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />CONDENSER UNIT <br />AIR HANDLER----y <br />- <br />CONNECTION TO PAD <br />EXTERIOR WALL <br />y <br />3/4' PVC CONDENSATE DRAIN LINE <br />NOTE: MAIN COND. DRAIN 3/4' DIA. <br />OVER HEAD • 12' FROM STRUCTURE <br />EVAP. TRAY <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />TRN <br />REFRIGERANT LINES TO <br />PLATFORM <br />RETU <br />CONDENSING UNIT <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />FBCR 1TH EDITION (2020) <br />MECHANICAL BLDG. CODE <br />SECTION 3012.4 <br />HVAC <br />DRAINS <br />SCORIATED NICKEL FIN. FLOOR COUNTERSUNK <br />BRONZE FL. PL. OR WALL C.O. PLUG <br />BRASS PLUG <br />—��FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />WADE 8240-K JOSAM 86000 <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.V.0 OPTI/SPEC <br />OFLOOR SLAB CLEAN —OUT (TYP <br />FIN. GRADE <br />OR PAVING <br />SEE SPEC. <br />1'-8'X8' CONC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />vEXT. GROUND CLEAN —OUT (TYPN <br />■ <br />MECHANICAL PLAN <br />SCALE: 1/4 • I'-0' <br />NOTE: <br />ALL MECHANICAL EQUIPMENT <br />SHALL DE INSTALLED AT OR <br />ABOVE F.P.E. ELEVATION. <br />i44i N. RONALD REAGAN BLVD. <br />LONGWOOD, FL32750 <br />PH: 407-774-6078 <br />FAX: 407-774-4078 <br />www.abdesigngroup.com <br />AA A: 0003325 <br />04 <br />rr <br />s <br />xx. <br />A <br />S <br />BVHDIV de ' T: <br />ABBOTT PARK <br />LOT #2 <br />BLK #13 <br />PROJECT <br />04181.006-02131 <br />MODEia <br />4EBB <br />"1828-CAU" <br />GARAGE 91r MG: <br />LEFT <br />PAGE: <br />MECHANICAL <br />PLAN <br />160 MPH E . C <br />