Laserfiche WebLink
INSTALL 6' SELF -ADHERING <br />MEMBRANE FLASHING OVER <br />TOP, SIDE($) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SEQUENCE OF FLASHING TO BE: <br />I. BOTTOM. 2. SIDES. 3. TOP <br />I' X: <br />VENT CAP IS TO BE SET IN BED <br />OF SEALANT AT TOP AND <br />}'..,-. <br />SIDES ONLY. SEALANT IS TO BE <br />TOOLED 60 AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />i_ <br />JOINTS AND INTERSECTIONS <br />APPLY SEALANT AT PERIMETER OF <br />BACKER ROD <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDES, Y.' CAULKING a JOINT <br />ALL AROUND <br />I <br />PER SECTION R703. <br />Exterior lathing and plestedna <br />I <br />Exterior use of portland cement plaster <br />BACKER ROD <br />shall comply with the application <br />-- <br />requirements of ASTM C 926-18L <br />X: <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1063-19a. <br />1;XS <br />or ASTM1787. <br />WRS LAYER 9, <br />STUCCO WRAP <br />HOODED VENT <br />COAT CEMENT <br />PLTHICK AS R3 <br />METAL LATH <br />WRB LAYER Q, FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER VENT <br />(FRAME) <br />WOOD SHEATHING <br />LAYER h, <br />STUCCO WRAP <br />LAYER 4, FORTIFIBER <br />BUILDING PAPER <br />woDD <br />coNaTucnoN <br />—METAL LATH <br />3� <br />6' d"PJ VINYL GA6iNG BEAD <br />W RAISED BAND <br />V TON MID -WALL <br />iiese araeen <br />W WIDE STRIP SELF <br />ADME61YE FLAGWING. CLEAN <br />MA6ONFtY BEFORE APPLYING <br />Z FLA6HIKa <br />STONE VENEER <br />OVER SCRATCH COAT <br />HORIZONTAL WEEP SCREED <br />WZSTONE VENEER <br />(FRAME TO BLOCK <br />LEGEND <br />DRAINAGE PLANE (LURE <br />LAYER 01, STUCCO LURAP) <br />WRB LAYER "2 (FORTIRBER — — — — — <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />WOOD OR 1/16' ZIP WALL <br />SHEATHING <br />SELF-ADHESIVE FLASHING — — — — — <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R103.1.1 / ASTM C-841-14a, MIN. 2S LBS. <br />PER 50. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />FLASHING <br />UNIT <br />PREMANUR DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT • <br />TOP 4 SIDES <br />GB DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' <br />PIPE THROUGH / <br />WALL <br />I <br />6' SELF ADHESIVE — <br />FLASHING (INSTALL <br />PER MANUF. SPECS <br />BUILDING PAPER <br />UNDER 'QUICK FLASH' <br />�_�VENT PENETRATION <br />SCALE: N.T.S. <br />ELEC. METED <br />VERIFY LO <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />I� <br />`ELEC. METER FIELD <br />VERIFY LOCATION <br />I <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />""� "�R SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />CONSTRUCTION <br />WOOD SHEATHING <br />WRB LAYER M, <br />STUCCO WRAP <br />WRB LAYER 02, FORTIF15ER <br />BUILDING PAPER <br />THICK, 3 COAT CEMENT <br />PLASTER <br />1b' TO Ya' MID -WALL <br />WEEP SCREED <br />�6' SELF-ADHESIVE <br />FLASHING <br />WOOD FRAMED <br />WALL <br />HORIZONTAL WEEP SCREED <br />( FRAME TO FRAMEZ <br />:O SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LAYER 'I, <br />STUCCO WRAP <br />WOOD SHEATHING <br />APPROVED <br />HOUSEWRAP <br />BELOW <br />THAT 9 <br />RANE <br />BOX, <br />FACE <br />EDGE <br />CUT SUCH <br />NO MEMB <br />ENTERS <br />APPLY TO <br />0� <br />WOOD SHEATHING <br />WRB LAYER -1, <br />STUCCO WRAP <br />WRB LAYER -2, FORTIFIBER <br />BUILDING PAPER <br />METAL LATH <br />FASTEN TO WOOD GTRUCTURAL <br />MEMBER T' O.C. MAX <br />K' TO )j' MID•WALL <br />W EP aCREED <br />ADHEI IVE FLASHNG, CLEAN <br />MA60NRY BEFORE APFL7NG <br />HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK) <br />S' <br />WRB LAYER h, <br />STUCCO WRAP <br />CUT 'X' INTO <br />SELF -ADHERING <br />MEMBRANE FLASHING <br />APPLY SELF -ADHERING <br />MEMBRANE FLASHING <br />OVER BOX AND OVER <br />APPROVED WRB <br />LAYER '1 <br />STEP #1 STEP #2 <br />APPLY E-Z BEAD <br />OVER 6O MIN <br />GRADE '0' <br />FELT -PROVIDE <br />SEALANT AT ALL <br />JOINTS AND <br />INTERSECTIONS <br />STEP #3 <br />WRB LAYER M, <br />STUCCO WRAP <br />APPLY 60 MIN <br />SELF-ADHERNCs <br />GRADE 'D' FELT <br />MEMBRANE FLASHING <br />OVER <br />SELF-ADHERNG <br />FLASHING OVER <br />APROVED <br />HOUSEWRAP <br />WRB LAYER 02, FORTIP15ER <br />BUILDING: PAPER <br />STEP #4 <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ C.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />METAL LATH <br />IS <br />5TEF #5 STEF #(o <br />nELECTRICAL RECEPTACLE <br />1441 N. RONALD RFAGAN BLVD <br />LONGWOOD,FL32750 <br />PH: 407-774-6078 <br />FAX: 407-7744078 <br />www.abdeslgngroup.com <br />AA #: 0003326 <br />y <br />J <br />W <br />SP <br />m <br />1 <br />S <br />I] <br />LU <br />q <br />U <br />a <br />2 <br />SUBDIV. Ae MT: <br />ABBOTT PARK <br />LOT #37 <br />BLK #7 <br />PROJECT# <br />04181.000-37071 <br />UODEL: <br />E401 <br />°2828-ENSLEY' <br />GARAGE 8111MG: <br />RIGHT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />%160 MPH EXP. C <br />202 <br />PRINT 09/21 21 <br />DATE: / <br />SCALE: 1/4"=1'-0" <br />SHE�E�TT <br />dd A2 <br />