My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7733 Broad Pointe Dr
Zephyrhills
>
Building Department
>
Building Plans
>
7733 Broad Pointe Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 9:43:01 PM
Creation date
2/24/2025 10:03:25 AM
Metadata
Fields
Template:
Building Plans
Street #
7733
Location
Broad Pointe Dr
Contractor
D R Horton
Building Plans - Permit #
156
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT 64ALL, BE PROVIDED UTH PROPER CLEARANCE, FOR SERVICMG, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED N NON-COIJDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATNG. ALL SEAMS SHALL BE SEALED UTH GLA66 PAS 4 MASTIC, AND <br />INSTALLED AS PER PBC 6TH EDITION (2011) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL ISI CLASS I AIR DUCT AS PER NPPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHPNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />S. ALL EXHAUST AND OUTSIDE AIR MET DUCTS, SMALL BE CONSTRUCTED OF SMOOTH GALV. METAL, <br />OR OTHER MATERIALS AS PER FISC 6TH EDITION (201) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 6TH EDITION <br />(2011) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH POO 67W EDITION (2011) MECHANICAL CODE SECTICN <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, 844ALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9. ALL PIPE RATED CEILING AND WALLS SHALL HAVE AN APPROVED PIPE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCE66 DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601. <br />10. GRILLE6 AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />IL DRYER BOOSTER TO BE A FANTECW DBF BOOSTER FAN OR EQUAL. <br />PANTECN DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET UTH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- 8UPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TRUNK <br />l <br />BALANCING DAMPER OR ODD <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN s LIGHT <br />CIA <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />m <br />PA86-THRU AIR GRILL <br />NOSE, <br />ALL HVAC TO HAVE PROPER <br />PANG W/ DRAINS <br />SECURE STRAP TO CONC. <br />ATTIC <br />W/ (2)-3/I6'X2' TAPGONB <br />UNIITT <br />SIMPSON W15 ROLL STRAP <br />OR EQUAL <br />CEILING <br />O <br />O <br />EXTERIOR WALL <br />PLENUM <br />T <br />y <br />AIR RETURN <br />4' CONCRETE SLAB SECURE STRAP TO UNIT W/ (2) <br />RSXI 1/4' SHT. MTL. SCREWS <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />1 <br />REFRIGERANT LINES <br />CONDENSER UNIT <br />AIR HANDLER <br />1 <br />CONNECTION TO PAD <br />EXTERIOR WALL <br />1 <br />3/4' PVC CONDENSATE DRAM LINE <br />NOTE, MAN COND. DRAIN 3/4' DIA <br />OVER HEAD • 12' FROM STRUCTURE <br />EVAP. TRAY <br />PVC SLEEVE TO LINES BELOW SLAB <br />T <br />REFRIGERANT LINES TO <br />PLATFORM <br />RETURN <br />CONDENSING UNIT <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />VMECHANICALMD6.0,001! <br />PDCR 6TW EDITION (2011) <br />SECTION 3017A <br />HVAC <br />DRAINS <br />SCORIATED NICKEL /- FIN. FLOOR COUNTERSUNK <br />BRONZE FL. FL. / OR WALL CA. PLUG <br />FITTING OR EXTENSION TO <br />601L OR WASTE AS <br />REQUIRED <br />WADE 6240-K J08AM 560M <br />INSIDE HSERIES NICKEL BRASS TOP <br />CAULK P.VG OPTI/8PEC <br />(J)FLOOR SLAB CLEAN —OUT (T <br />FIR GRADE <br />OR PAVING <br />SEE OPEC. <br />1'-81X8' CONIC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />nEXT. GROUND CLEAN -OUT (TY <br />NOTE. <br />ALL MECHANICAL EQUIPMENT <br />SHALL BE INSTALLED AT OR <br />ABOVE PPAL ELEVATION. <br />MECHANICAL PLAN <br />SCALE, 1/4 . 1'-0' <br />C <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407.7748078 <br />FAX: 407.7744078 <br />W W W.Obdes(gngmup.com <br />AA M: 0003325 <br />a <br />°a <br />Sp <br />BLU'1mm !e LoTs <br />ABBOTT PARK <br />LOT #1 <br />BLK. # 10 <br />r JlUCT04181.006-01102 <br />MOD3L.• <br />4EBB <br />"1828-CALI" <br />GARAoa EIMNGU <br />RIGHT <br />PAGL': <br />MECHANICAL <br />PLAN <br />160 MPH EXP. C <br />57AFO�l <br />OFM <br />1A <br />9 <br />M <br />D � 11/26 119 <br />sCAXA: 1/4'=1'-O" <br />see <br />M1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.