My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7745 Sail Clover Ln
Zephyrhills
>
Building Department
>
Building Plans
>
7745 Sail Clover Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 10:56:05 PM
Creation date
2/24/2025 9:29:47 AM
Metadata
Fields
Template:
Building Plans
Street #
7745
Location
Sail Clover Ln
Contractor
D R Horton
Building Plans - Permit #
3213
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICNG, PER <br />MP& REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS PAS 8 MASTIC. AND <br />INSTALLED AS PER FBC TTH EDITION (2020) MECHANICAL BLD& CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEVER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, &WALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC TTH EDITION (2020) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED N ACCORDANCE TO FIBC TTH EDITION <br />(2020) MECHANICAL CODE 603.1 <br />T. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 1TH EDITION (2020) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOM&, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9. ALL FIRE RATED CEILINGS AND WALL& SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS &HALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC 1TH <br />EDITION (2020) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED OATH BALANCING DAMPERS. <br />IL DRYER BOOSTER TO BE A FANTECH OBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />NOTE: <br />ALL HVAC TO HAVE PROPER <br />PAN& W/ DRAINS <br />ATTIC <br />CEILING <br />O _ <br />EXTERIOR WALL <br />PLENUM <br />T y <br />AIR RETURN <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />y <br />AIR HANDLER <br />EXTERIOR WALL <br />y <br />3/4' PVC CONDENSATE DRAIN LINE <br />EVAP. TRAY <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />T <br />REFRIGERANT LINES TO <br />PLATFORM <br />RETURN <br />CONDENSING WIT <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />FBCR TTH EDITION (2020) <br />MECHANICAL BLDG. CODE <br />SECTION "'12.4 <br />HVAC <br />DRAINS <br />SCORIATED NICKEL FN. FLOOR <br />BRONZE FL. PL. OR WALL <br />BRASS PLUG <br />—� FITTING OR EXTENSION TO <br />BOIL OR WASTE AS <br />REQUIRED <br />//-- WADE 8240-K JOSAM 86000 <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.V.0 OPTI/SPEC <br />FLOOR SLAB CLEAN —OUT (TYPN <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR 1 WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />BROKEN LINE- RETURN TRUNK <br />l <br />BALANCING DAMPER OR OBD <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN A LIGHT <br />O/A <br />OUTSIDE AIR <br />8 <br />THERMOSTAT <br />m <br />PA86-THRU AIR GRILL <br />SECURE STRAP TO CONG. CONDENSER <br />W/ (2)-3/I6'X2' TAFCONS UNIT SIMPSON WB ROLL STRAP <br />OR EQUAL <br />4' CONCRETE &LAB SECURE STRAP TO WIT W/ (2) <br />%XI 1/4' SHT. MTL. SCREWS <br />CONDENSER UNIT <br />CONNECTION TO PAD <br />NOTE: MAN COND. DRAIN 3/4' DIA. <br />OVER HEAD • 12' FROM STRUCTURE <br />CO:cLoO7.PLU3 <br />UNK <br />I' -6'mGRADE <br />PAVING <br />SEE SPEC. <br />P-awl CONC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />NEXT. GROUND CLEAN —OUT (TYPN) <br />MECHANICAL PLAN <br />SCALE: V4 • I'-0' <br />NOTE: <br />ALL MECHANICAL EQUIPMENT <br />SHALL BE INSTALLED AT OR <br />ABOVE F.P.E. ELEVATION. <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-774-4078 <br />WwW.abd"Igngroup.com <br />AA S: 0003325 <br />i� <br />m <br />@ <br />k <br />e <br />S <br />o <br />fS <TSDIV. de LOT: <br />ABBOTT PARK <br />LOT #33 <br />BLK. #7 <br />PIROJMCT:p <br />04181.000-33071 <br />>t ODZIU <br />4EBB <br />"1828-CALI" <br />GAP-tOZ SVIWO: <br />RIGHT <br />PALM: <br />MECHANICAL <br />PLAN <br />160 MPH EXP. C <br />n <br />NO rDATIM 9/21/21 <br />8CALE: 1/4"=1'-0 <br />a13ffi!UT <br />M1 <br />